scholarly journals Resequencing theEscherichia coligenome by GenoCare single molecule sequencing platform

2017 ◽  
Author(s):  
Luyang Zhao ◽  
Liwei Deng ◽  
Gailing Li ◽  
Huan Jin ◽  
Jinsen Cai ◽  
...  

ABSTRACTNext generation sequencing (NGS) has revolutionized life sciences research. Recently, a new class of third-generation sequencing platforms has arrived to meet increasing demands in the clinic, capable of directly measuring DNA and RNA sequences at the single-molecule level without amplification. Here, we use the new GenoCare single molecule sequencing platform from Direct Genomics to resequence theE. coligenome and show comparable performance to the Illumina MiSeq system. Our platform detects single-molecule fluorescence by total internal reflection microscopy, with sequencing-by-synthesis chemistry. With a consensus sequence of 99.71% nucleotide identity to that of the Illumina MiSeq system’s, GenoCare was determined to be a reliable platform for single-molecule sequencing, with strong potential for clinical applications.

2017 ◽  
Author(s):  
Luyang Zhao ◽  
Liwei Deng ◽  
Gailing Li ◽  
Huan Jin ◽  
Jinsen Cai ◽  
...  

ABSTRACTThird generation sequencing is a direct measurement of DNA/RNA sequences at the single molecule level without amplification. In this study, we report sequencing of the genome of the M13 virus by a new single molecule sequencing platform. Our platform detects single molecule fluorescence by the total internal reflection microscope technique, with sequencing-by-synthesis chemistry. We sequenced the genome of M13 to a depth of 316x and 100% coverage. The consensus sequence accuracy is 100%. We demonstrated that single molecule sequencing has no significant GC bias.


2020 ◽  
Author(s):  
Liang Hu ◽  
Qunting Lin ◽  
Pingyuan Xie ◽  
Lidong Zeng ◽  
Lichun Liu ◽  
...  

ABSTRACTA technical problem of characterizing copy number variation of several cells with next-generation sequencing is the whole genome amplification induced bias. The result of CNVs and mosaicism detection is affected by the GC bias. Here, we report a rapid non-WGA sample preparation strategy for a single-molecule sequencing platform GenoCare1600. This approach, combined with a single-molecule sequencing platform that avoids the use of WGA and bridge PCR processes, can provide higher reliability with its lower GC bias. By combining our optimized Tn5-based transposon insertion approach with GenoCare, we successfully detected CNVs as small as 1.29M and mosaicism as small as 20%, which is consistent with next-generation sequencing (NGS) data. Moreover, our GenoCare-TTI protocol showed less GC bias and less Mad of Diff. These results suggest that the optimized TTI approach, together with the GenoCare1600 sequencing platform, is a promising option for CNV characterization from maybe one single cell.


GigaScience ◽  
2020 ◽  
Vol 9 (8) ◽  
Author(s):  
Marcela Sandoval-Velasco ◽  
Juan Antonio Rodríguez ◽  
Cynthia Perez Estrada ◽  
Guojie Zhang ◽  
Erez Lieberman Aiden ◽  
...  

Abstract Background Hi-C experiments couple DNA-DNA proximity with next-generation sequencing to yield an unbiased description of genome-wide interactions. Previous methods describing Hi-C experiments have focused on the industry-standard Illumina sequencing. With new next-generation sequencing platforms such as BGISEQ-500 becoming more widely available, protocol adaptations to fit platform-specific requirements are useful to give increased choice to researchers who routinely generate sequencing data. Results We describe an in situ Hi-C protocol adapted to be compatible with the BGISEQ-500 high-throughput sequencing platform. Using zebra finch (Taeniopygia guttata) as a biological sample, we demonstrate how Hi-C libraries can be constructed to generate informative data using the BGISEQ-500 platform, following circularization and DNA nanoball generation. Our protocol is a modification of an Illumina-compatible method, based around blunt-end ligations in library construction, using un-barcoded, distally overhanging double-stranded adapters, followed by amplification using indexed primers. The resulting libraries are ready for circularization and subsequent sequencing on the BGISEQ series of platforms and yield data similar to what can be expected using Illumina-compatible approaches. Conclusions Our straightforward modification to an Illumina-compatible in situHi-C protocol enables data generation on the BGISEQ series of platforms, thus expanding the options available for researchers who wish to utilize the powerful Hi-C techniques in their research.


2020 ◽  
Vol 11 (11) ◽  
pp. 792-808 ◽  
Author(s):  
Lin-Yong Zhao ◽  
Jinghui Song ◽  
Yibin Liu ◽  
Chun-Xiao Song ◽  
Chengqi Yi

Abstract Over 17 and 160 types of chemical modifications have been identified in DNA and RNA, respectively. The interest in understanding the various biological functions of DNA and RNA modifications has lead to the cutting-edged fields of epigenomics and epitranscriptomics. Developing chemical and biological tools to detect specific modifications in the genome or transcriptome has greatly facilitated their study. Here, we review the recent technological advances in this rapidly evolving field. We focus on high-throughput detection methods and biological findings for these modifications, and discuss questions to be addressed as well. We also summarize third-generation sequencing methods, which enable long-read and single-molecule sequencing of DNA and RNA modification.


2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Xiaoying Fan ◽  
Cheng Yang ◽  
Wen Li ◽  
Xiuzhen Bai ◽  
Xin Zhou ◽  
...  

AbstractThere is no effective way to detect structure variations (SVs) and extra-chromosomal circular DNAs (ecDNAs) at single-cell whole-genome level. Here, we develop a novel third-generation sequencing platform-based single-cell whole-genome sequencing (scWGS) method named SMOOTH-seq (single-molecule real-time sequencing of long fragments amplified through transposon insertion). We evaluate the method for detecting CNVs, SVs, and SNVs in human cancer cell lines and a colorectal cancer sample and show that SMOOTH-seq reliably and effectively detects SVs and ecDNAs in individual cells, but shows relatively limited accuracy in detection of CNVs and SNVs. SMOOTH-seq opens a new chapter in scWGS as it generates high fidelity reads of kilobases long.


BMC Genomics ◽  
2021 ◽  
Vol 22 (1) ◽  
Author(s):  
Yongfeng Liu ◽  
Ran Han ◽  
Letian Zhou ◽  
Mingjie Luo ◽  
Lidong Zeng ◽  
...  

Abstract Background GenoLab M is a recently established next-generation sequencing platform from GeneMind Biosciences. Presently, Illumina sequencers are the globally leading sequencing platform in the next-generation sequencing market. Here, we present the first report to compare the transcriptome and LncRNA sequencing data of the GenoLab M sequencer to NovaSeq 6000 platform in various types of analysis. Results We tested 16 libraries in three species using various library kits from different companies. We compared the data quality, genes expression, alternatively spliced (AS) events, single nucleotide polymorphism (SNP), and insertions–deletions (InDel) between two sequencing platforms. The data suggested that platforms have comparable sensitivity and accuracy in terms of quantification of gene expression levels with technical compatibility. Conclusions Genolab M is a promising next-generation sequencing platform for transcriptomics and LncRNA studies with high performance at low costs.


2016 ◽  
Author(s):  
Chen Yang ◽  
Justin Chu ◽  
Ren&eacute L Warren ◽  
Inanç Birol

Motivation: In 2014, Oxford Nanopore Technologies (ONT) announced a new sequencing platform called MinION. The particular features of MinION reads, longer read lengths and single-molecule sequencing in particular, show potential for genome characterization. As of yet, the pre-commercial technology is exclusively available through early-access, and only a few datasets are publically available for testing. Further, no software exists that simulates MinION platform reads with genuine ONT characteristics. Results: In this article, we introduce NanoSim, a fast and scalable read simulator that captures the technology-specific features of ONT data, and allows for adjustments upon improvement of nanopore sequencing technology. Availability: NanoSim is written in Python and R. The source files and manual are available at the Genome Sciences Centre website: http://www.bcgsc.ca/platform/bioinfo/software/nanosim


Blood ◽  
2013 ◽  
Vol 122 (21) ◽  
pp. 230-230 ◽  
Author(s):  
Doron Lipson ◽  
Michelle K Nahas ◽  
Geoff A. Otto ◽  
Roman Yelensky ◽  
Omar Abdel-Wahab ◽  
...  

Abstract Background Rapid advancements in cancer genomics and in the development of targeted therapies provide expanding opportunities to use genomic profiling to improve patient outcomes. However, most patients do not have access to clinical genomic profiling platforms, and currently available assays capture a small set of known mutations or translocations tailored to specific tumor types. The spectrum of somatic alterations in leukemia, lymphoma, and myeloma includes substitutions, insertions/deletions (indels), copy number alterations (CNAs) and gene fusions; no current assay captures the different types of alterations in a single clinical genomic test. We developed a novel, CLIA-certified next-generation sequencing-based assay designed to provide targeted assessment of the genomic landscape of hematologic malignancies, including identification of all classes of genomic alterations using archived FFPE, blood and bone marrow aspirate samples with high accuracy in a clinically relevant timeframe. Methods DNA and RNA were successfully extracted from 350/362 (96%) specimens from 319 patients, including 57 FFPE samples, 150 blood samples and 142 bone marrow aspirates. The initial sample cohort included 20 ALL, 83 AML, 53 CLL, 57 DLBCL, 48 MDS, 32 MPN and 57 multiple myeloma samples. Adaptor ligated sequencing libraries were captured by solution hybridization using a custom bait-set targeting 374 cancer-related genes and 24 frequently rearranged genes by DNA-seq, and 258 frequently-rearranged genes by RNA-seq. All captured libraries were sequenced to high depth (Illumina HiSeq) in a CLIA-certified laboratory (Foundation Medicine), averaging 590x for DNA and >20M total pairs for RNA, to enable the sensitive and specific detection of substitutions, indels, CNAs and gene fusions. Results Sufficient tumor content (≥20%) was present in 317/350 (91%) of the samples (289/319 patients), and a total of 885 alterations were identified (3.1 alterations per sample), including 555 base substitutions, 213 indels, 36 splice mutations, 51 CNAs and 36 fusions/rearrangements. The most frequent alterations across all hematologic malignancies included mutations in TP53 (9%), ASXL1, KRAS, NRAS, IDH2, TET2, SF3B1, JAK2, MLL2, DNMT3A, RUNX1, and SRSF2 (2-5% each); FLT3 ITDs (2%); MLL PTDs (1%); homozygous loss of CDKN2A/B (3%); and focal amplification of REL (1%). Rearrangements in BCL2/6, MYC, MLL, MLL2, NOTCH2, ABL1 and ETV6 were identified using DNA and RNA targeted sequencing, demonstrating the ability of this platform to reliably identify gene fusions with immediate clinical relevance. Overall high accuracy of the assay for substitutions, indels and CNAs was previously demonstrated by extensive validation studies achieving 95-99% across alteration types with high specificity (PPV>99%) [Frampton et al, Nat Biotech, in press]. Comparison of detected alterations to previous molecular testing for JAK2, NPM1, IDH2, FLT3 and CEBPA in MPN/AML samples demonstrated 97% sensitivity (33/34) in our ability to identify known mutations in these clinical samples. We identified additional clinically relevant mutations that were not detected using standard clinical assays, including alterations in JAK2, FLT3 and IDH2, which can inform therapeutic decisions. The use of our content rich sequencing platform allowed us to identify clinically actionable mutations in hematologic malignancies, including IDH1/2 mutations in a spectrum of myeloid/lymphoid malignancies, recurrent BRAF mutations in refractory CLL and myeloma, and mutations in the JAK-STAT signaling pathway in diffuse-large B cell lymphoma. These results demonstrate that a targeted sequencing platform which includes a large set of known disease alleles/therapeutic targets can identify mutations with therapeutic relevance in disease contexts where gene-specific assays are not currently performed in the clinical setting. Conclusions We have developed a sensitive, high throughput assay to detect somatic alterations in hundreds of genes known to be deregulated in hematologic malignancies, which can be used for clinical sequencing of frozen/paraffin samples. We demonstrate that targeted DNA and RNA sequencing can be used to identify all classes of genomic alterations in genes known to be therapeutic targets in a broad spectrum of hematologic malignancies. Disclosures: Lipson: Foundation Medicine, Inc: Employment, Equity Ownership. Nahas:Foundation Medicine, Inc: Employment, Equity Ownership. Otto:Foundation Medicine, Inc: Employment, Equity Ownership. Yelensky:Foundation Medicine, Inc: Employment, Equity Ownership. Wang:Foundation Medicine, Inc: Employment, Equity Ownership. He:Foundation Medicine, Inc: Employment, Equity Ownership. Rampal:Foundation Medicine: Consultancy. Brennan:Foundation Medicine, Inc: Employment, Equity Ownership. Brennan:Foundation Medicine, Inc: Employment, Equity Ownership. Young:Foundation Medicine, Inc: Employment, Equity Ownership. Donahue:Foundation Medicine, Inc: Employment, Equity Ownership. Sanford:Foundation Medicine, Inc: Employment, Equity Ownership. Greenbowe:Foundation Medicine, Inc: Employment, Equity Ownership. Frampton:Foundation Medicine, Inc: Employment, Equity Ownership. Fichtenholtz:Foundation Medicine, Inc: Employment, Equity Ownership. Young:Foundation Medicine, Inc: Employment, Equity Ownership. Erlich:Foundation Medicine, Inc: Employment, Equity Ownership. Parker:Foundation Medicine, Inc: Employment, Equity Ownership. Ross:Foundation Medicine, Inc: Employment, Equity Ownership. Stephens:Foundation Medicine, Inc: Employment, Equity Ownership. Miller:Foundation Medicine, Inc: Employment, Equity Ownership. Levine:Foundation Medicine, Inc: Consultancy.


2019 ◽  
Author(s):  
Nicolas Cardozo ◽  
Karen Zhang ◽  
Katie Doroschak ◽  
Aerilynn Nguyen ◽  
Zoheb Siddiqui ◽  
...  

AbstractGenetically encoded reporter proteins are a cornerstone of molecular biology. While they are widely used to measure many biological activities, the current number of uniquely addressable reporters that can be used together for one-pot multiplexed tracking is small due to overlapping detection channels such as fluorescence. To address this, we built an expanded library of orthogonally-barcoded Nanopore-addressable protein Tags Engineered as Reporters (NanoporeTERs), which can be read and demuxed by nanopore sensors at the single-molecule level. By adapting a commercially available nanopore sensor array platform typically used for real-time DNA and RNA sequencing (Oxford Nanopore Technologies’ MinION), we show direct detection of NanoporeTER expression levels from unprocessed bacterial culture with no specialized sample preparation. These results lay the foundations for a new class of reporter proteins to enable multiplexed, real-time tracking of gene expression with nascent nanopore sensor technology.


2021 ◽  
Author(s):  
Yongfeng Liu ◽  
Ran Han ◽  
Letian Zhou ◽  
Mingjie Luo ◽  
Lidong Zeng ◽  
...  

Abstract Background: GenoLab M is a recently established next-generation sequencing platform from GeneMind Biosciences. Presently, Illumina sequencers are the globally leading sequencing platform in the next-generation sequencing market. Here, we present the first report to compare the transcriptome and LncRNA sequencing data of the GenoLab M sequencer to NovaSeq 6000 platform in various types of analysis.Results: We tested 16 libraries in three species using various library kits from different companies. We compared the data quality, genes expression, alternatively spliced (AS) events, single nucleotide polymorphism (SNP), and insertions–deletions (InDel) between two sequencing platforms. The data suggested that platforms have comparable sensitivity and accuracy in terms of quantification of gene expression levels with technical compatibility. Conclusions: Genolab M is a promising sequencing platform for transcriptomics and LncRNA studies with high performance at low costs.


Sign in / Sign up

Export Citation Format

Share Document