scholarly journals poRe: an R package for the visualization and analysis of nanopore sequencing data

2014 ◽  
Author(s):  
Mick Watson ◽  
Marian Thomson ◽  
Judith Risse ◽  
Javier Santoyo-Lopez ◽  
Richard Talbot ◽  
...  

Motivation: The Oxford Nanopore MinION device represents a unique sequencing technology. As a mobile sequencing device powered by the USB port of a laptop, the MinION has huge potential applications. To enable these applications, the bioinformatics community will need to design and build a suite of tools specifically for MinION data. Results: Here we present poRe, a package for the statistical software R that enables users to manipulate, organize, summarise and visualize MinION nanopore sequencing data. As a packge for R, poRe has been tested on both Windows and Linux. Crucially, the Windows version allows users to analyse MinION data on the Windows laptop attached to the device Availability: Pre-built R packages for Windows and Linux are available under a BSD license at http://sourceforge.net/projects/rpore/ Contact: [email protected]

PLoS ONE ◽  
2019 ◽  
Vol 14 (5) ◽  
pp. e0216471 ◽  
Author(s):  
Davide Bolognini ◽  
Niccolò Bartalucci ◽  
Alessandra Mingrino ◽  
Alessandro Maria Vannucchi ◽  
Alberto Magi

2021 ◽  
Vol 12 ◽  
Author(s):  
Davide Bolognini ◽  
Alberto Magi

Structural variants (SVs) are genomic rearrangements that involve at least 50 nucleotides and are known to have a serious impact on human health. While prior short-read sequencing technologies have often proved inadequate for a comprehensive assessment of structural variation, more recent long reads from Oxford Nanopore Technologies have already been proven invaluable for the discovery of large SVs and hold the potential to facilitate the resolution of the full SV spectrum. With many long-read sequencing studies to follow, it is crucial to assess factors affecting current SV calling pipelines for nanopore sequencing data. In this brief research report, we evaluate and compare the performances of five long-read SV callers across four long-read aligners using both real and synthetic nanopore datasets. In particular, we focus on the effects of read alignment, sequencing coverage, and variant allele depth on the detection and genotyping of SVs of different types and size ranges and provide insights into precision and recall of SV callsets generated by integrating the various long-read aligners and SV callers. The computational pipeline we propose is publicly available at https://github.com/davidebolo1993/EViNCe and can be adjusted to further evaluate future nanopore sequencing datasets.


Author(s):  
L J Kerkhof

Abstract This minireview will discuss the improvements in Oxford Nanopore sequencing technology which make the MinION a viable platform for microbial ecology studies. Specific issues being addressed are the increase in sequence accuracy from 65–96.5% during the last 5 years, the ability to obtain a quantifiable/predictive signal from the MinION with respect to target molecule abundance, simple-to-use GUI-based pathways for data analysis, and the modest additional equipment needs for sequencing in the field. Coupling these recent improvements with the low capital costs for equipment and the reasonable per sample cost makes MinION sequencing an attractive option for virtually any laboratory.


Blood ◽  
2018 ◽  
Vol 132 (Supplement 1) ◽  
pp. 1847-1847 ◽  
Author(s):  
Adam Burns ◽  
David Robert Bruce ◽  
Pauline Robbe ◽  
Adele Timbs ◽  
Basile Stamatopoulos ◽  
...  

Abstract Introduction Chronic Lymphocytic Leukaemia (CLL) is the most prevalent leukaemia in the Western world and characterised by clinical heterogeneity. IgHV mutation status, mutations in the TP53 gene and deletions of the p-arm of chromosome 17 are currently used to predict an individual patient's response to therapy and give an indication as to their long-term prognosis. Current clinical guidelines recommend screening patients prior to initial, and any subsequent, treatment. Routine clinical laboratory practices for CLL involve three separate assays, each of which are time-consuming and require significant investment in equipment. Nanopore sequencing offers a rapid, low-cost alternative, generating a full prognostic dataset on a single platform. In addition, Nanopore sequencing also promises low failure rates on degraded material such as FFPE and excellent detection of structural variants due to long read length of sequencing. Importantly, Nanopore technology does not require expensive equipment, is low-maintenance and ideal for patient-near testing, making it an attractive DNA sequencing device for low-to-middle-income countries. Methods Eleven untreated CLL samples were selected for the analysis, harbouring both mutated (n=5) and unmutated (n=6) IgHV genes, seven TP53 mutations (five missense, one stop gain and one frameshift) and two del(17p) events. Primers were designed to amplify all exons of TP53, along with the IgHV locus, and each primer included universal tails for individual sample barcoding. The resulting PCR amplicons were prepared for sequencing using a ligation sequencing kit (SQK-LSK108, Oxford Nanopore Technologies, Oxford, UK). All IgHV libraries were pooled and sequenced on one R9.4 flowcell, with the TP53 libraries pooled and sequenced on a second R9.4 flowcell. Whole genome libraries were prepared from 400ng genomic DNA for each sample using a rapid sequencing kit (SQK-RAD004, Oxford Nanopore Technologies, Oxford, UK), and each sample sequenced on individual flowcells on a MinION mk1b instrument (Oxford Nanopore Technologies, Oxford, UK). We developed a bespoke bioinformatics pipeline to detect copy-number changes, TP53 mutations and IgHV mutation status from the Nanopore sequencing data. Results were compared to short-read sequencing data obtained earlier by targeted deep sequencing (MiSeq, Illumina Inc, San Diego, CA, USA) and whole genome sequencing (HiSeq 2500, Illumina Inc, San Diego CA, USA). Results Following basecalling and adaptor trimming, the raw data were submitted to the IMGT database. In the absence of error correction, it was possible to identify the correct VH family for each sample; however the germline homology was not sufficient to differentiate between IgHVmut and IgHVunmut CLL cases. Following bio-informatic error correction and consensus building, the percentage to germline homology was the same as that obtained from short-read sequencing and nanopore sequencing also called the same productive rearrangements in all cases. A total of 77 TP53 variants were identified, including 68 in non-coding regions, and three synonymous SNVs. The remaining 6 were predicted to be functional variants (eight missense and two stop-gains) and had all been identified in early MiSeq targeted sequencing. However, the frameshift mutation was not called by the analysis pipeline, although it is present in the aligned reads. Using the low-coverage WGS data, we were able to identify del(17p) events, of 19Mb and 20Mb length, in both patients with high confidence. Conclusions Here we demonstrate that characterization of the IgHV locus in CLL cases is possible using the MinION platform, provided sufficient downstream analysis, including error correction, is applied. Furthermore, somatic SNVs in TP53 can be identified, although similar to second generation sequencing, variant calling of small insertions and deletions is more problematic. Identification of del(17p) is possible from low-coverage WGS on the MinION and is inexpensive. Our data demonstrates that Nanopore sequencing can be a viable, patient-near, low-cost alternative to established screening methods, with the potential of diagnostic implementation in resource-poor regions of the world. Disclosures Schuh: Giles, Roche, Janssen, AbbVie: Honoraria.


2019 ◽  
Author(s):  
Davide Bolognini ◽  
Niccolò Bartalucci ◽  
Alessandra Mingrino ◽  
Alessandro Maria Vannucchi ◽  
Alberto Magi

AbstractMinION and GridION X5 from Oxford Nanopore Technologies are devices for real-time DNA and RNA sequencing. On the one hand, MinION is the only real-time, low cost and portable sequencing device and, thanks to its unique properties, is becoming more and more popular among biologists; on the other, GridION X5, mainly for its costs, is less widespread but highly suitable for researchers with large sequencing projects. Despite the fact that Oxford Nanopore Technologies’ devices have been increasingly used in the last few years, there is a lack of high-performing and user-friendly tools to handle the data outputted by both MinION and GridION X5 platforms. Here we present NanoR, a cross-platform R package designed with the purpose to simplify and improve nanopore data visualization. Indeed, NanoR is built on few functions but overcomes the capabilities of existing tools to extract meaningful informations from MinION sequencing data; in addition, as exclusive features, NanoR can deal with GridION X5 sequencing outputs and allows comparison of both MinION and GridION X5 sequencing data in one command. NanoR is released as free package for R at https://github.com/davidebolo1993/NanoR.


F1000Research ◽  
2017 ◽  
Vol 6 ◽  
pp. 1750 ◽  
Author(s):  
Tapan Kumar Mondal ◽  
Hukam Chand Rawal ◽  
Kishor Gaikwad ◽  
Tilak Raj Sharma ◽  
Nagendra Kumar Singh

Oryza coarctata plants, collected from Sundarban delta of West Bengal, India, have been used in the present study to generate draft genome sequences, employing the hybrid genome assembly with Illumina reads and third generation Oxford Nanopore sequencing technology. We report for the first time that more than 85.71 % of the genome coverage and the data have been deposited in NCBI SRA, with BioProject ID PRJNA396417.


2016 ◽  
Author(s):  
Matei David ◽  
L.J. Dursi ◽  
Delia Yao ◽  
Paul C. Boutros ◽  
Jared T. Simpson

ABSTRACTMotivationThe highly portable Oxford Nanopore MinlON sequencer has enabled new applications of genome sequencing directly in the field. However, the MinlON currently relies on a cloud computing platform, Metrichor (metrichor.com), for translating locally generated sequencing data into basecalls.ResultsTo allow offline and private analysis of MinlON data, we created Nanocall. Nanocall is the first freely-available, open-source basecaller for Oxford Nanopore sequencing data and does not require an internet connection. On two E.coli and two human samples, with natural as well as PCR-amplified DNA, Nanocall reads have ~68% identity, directly comparable to Metrichor ”1D” data. Further, Nanocall is efficient, processing ~500Kbp of sequence per core hour, and fully parallelized. Using 8 cores, Nanocall could basecall a MinlON sequencing run in real time. Metrichor provides the ability to integrate the ”1D” sequencing of template and complement strands of a single DNA molecule, and create a ”2D” read. Nanocall does not currently integrate this technology, and addition of this capability will be an important future development. In summary, Nanocall is the first open-source, freely available, off-line basecaller for Oxford Nanopore sequencing data.AvailabilityNanocall is available at github.com/mateidavid/nanocall, released under the MIT license.Contactmatei.david at oicr.on.ca


Author(s):  
E. S. Gribchenko

The transcriptome profiles the cv. Frisson mycorrhizal roots and inoculated nitrogen-fixing nodules were investigated using the Oxford Nanopore sequencing technology. A database of gene isoforms and their expression has been created.


2019 ◽  
Vol 20 (1) ◽  
Author(s):  
Anbo Zhou ◽  
Timothy Lin ◽  
Jinchuan Xing

Abstract Background Structural variations (SVs) account for about 1% of the differences among human genomes and play a significant role in phenotypic variation and disease susceptibility. The emerging nanopore sequencing technology can generate long sequence reads and can potentially provide accurate SV identification. However, the tools for aligning long-read data and detecting SVs have not been thoroughly evaluated. Results Using four nanopore datasets, including both empirical and simulated reads, we evaluate four alignment tools and three SV detection tools. We also evaluate the impact of sequencing depth on SV detection. Finally, we develop a machine learning approach to integrate call sets from multiple pipelines. Overall SV callers’ performance varies depending on the SV types. For an initial data assessment, we recommend using aligner minimap2 in combination with SV caller Sniffles because of their speed and relatively balanced performance. For detailed analysis, we recommend incorporating information from multiple call sets to improve the SV call performance. Conclusions We present a workflow for evaluating aligners and SV callers for nanopore sequencing data and approaches for integrating multiple call sets. Our results indicate that additional optimizations are needed to improve SV detection accuracy and sensitivity, and an integrated call set can provide enhanced performance. The nanopore technology is improving, and the sequencing community is likely to grow accordingly. In turn, better benchmark call sets will be available to more accurately assess the performance of available tools and facilitate further tool development.


Sign in / Sign up

Export Citation Format

Share Document