scholarly journals Modeling Focused Ultrasound Exposure for the Optimal Control of Thermal Dose Distribution

2012 ◽  
Vol 2012 ◽  
pp. 1-11 ◽  
Author(s):  
E. Sassaroli ◽  
K. C. P. Li ◽  
B. E. O'Neill

Preclinical studies indicate that focused ultrasound at exposure conditions close to the threshold for thermal damage can increase drug delivery at the focal region. Although these results are promising, the optimal control of temperature still remains a challenge. To address this issue, computer-simulated ultrasound treatments have been performed. When the treatments are delivered without taking into account the cooling effect exerted by the blood flow, the resulting thermal dose is highly variable with regions of thermal damage, regions of underdosage close to the vessels, and areas in between these two extremes. When the power deposition is adjusted so that the peak thermal dose remains close to the threshold for thermal damage, the thermal dose is more uniformly distributed but under-dosage is still visible around the thermally significant vessels. The results of these simulations suggest that, for focused ultrasound, as for other delivery methods, the only way to control temperature is to adjust the average energy deposition to compensate for the presence of thermally significant vessels in the target area. By doing this, we have shown that it is possible to reduce the temperature heterogeneity observed in focused ultrasound thermal treatments.

Author(s):  
Н.Н. Петрищев ◽  
Д.Ю. Семенов ◽  
А.Ю. Цибин ◽  
Г.Ю. Юкина ◽  
А.Е. Беркович ◽  
...  

The purpose. In the study we investigated the impact of the partial blood flow shutdown on structural changes in the rabbit vena cava posterior wall after exposure to high-intensity focused ultrasound (HIFU). Methods. Ultrasound Exposure: frequency of 1.65 MHz, the ultrasound intensity in the focus of 13.6 kW/cm, the area of the focal spot 1 mm, continuous ultrasound, exposure for 3 seconds. Results. Immediately after HIFU exposure all layers of the vein wall showed characteristic signs of thermal damage. A week after exposure structural changes in the intima, media and adventitia was minimal in the part of vessel with preserved blood flow, and after 4 weeks the changes were not revealed. A week after HIFU exposure partial endothelium destruction, destruction of myocytes, disorganization and consolidation of collagen fibers of the adventitia were observed in an isolated segment of the vessel, and in 4 weeks endothelium restored and signs of damage in media and adventitia persisted, but were less obvious than in a week after exposure. Conclusion. The shutdown of blood flow after exposure to HIFU promotes persistent changes in the vein wall. Vein compression appears to be necessary for the obliteration of the vessel, when using HIFU-technology.


2010 ◽  
Vol 14 (2) ◽  
pp. 459-467 ◽  
Author(s):  
Mayada Tahir

Cornea thermal damage due to incidental continuous wave CO2 laser irradiation is studied numerically based on bio-heat equation. The interaction of laser with tissue leads to a rapid temperature increased in target and the nearby tissue. As the temperature of the eye surface reaches 44?C, a sensation of pain will cause aversion response of the reflex blink and/or shifting away from the source of pain. The aim of the work is to predict numerically the threshold limit of incidental laser power that causes damage to the anterior part of the cornea, which can be healed within 2-5 days as long as damage is not exceeding the outer part of the eye (epithelium). A finite element analysis is used to predict temperature distribution through the cornea where the necroses region can be obtained using thermal dose equation. The thermal dose that required for damaging the cornea is predicted from previously published experimental data on rhesus monkeys and used later as a limit for shrinkage to human cornea. The result of this work is compared by international standard of safety and a good nearby result is obtained which verified the result of this work.


2017 ◽  
Vol 2017 ◽  
pp. 1-7 ◽  
Author(s):  
A. Vargas-Olivares ◽  
O. Navarro-Hinojosa ◽  
M. Maqueo-Vicencio ◽  
L. Curiel ◽  
M. Alencastre-Miranda ◽  
...  

High-intensity focused ultrasound (HIFU) is a minimally invasive therapy modality in which ultrasound beams are concentrated at a focal region, producing a rise of temperature and selective ablation within the focal volume and leaving surrounding tissues intact. HIFU has been proposed for the safe ablation of both malignant and benign tissues and as an agent for drug delivery. Magnetic resonance imaging (MRI) has been proposed as guidance and monitoring method for the therapy. The identification of regions of interest is a crucial procedure in HIFU therapy planning. This procedure is performed in the MR images. The purpose of the present research work is to implement a time-efficient and functional segmentation scheme, based on the watershed segmentation algorithm, for the MR images used for the HIFU therapy planning. The achievement of a segmentation process with functional results is feasible, but preliminary image processing steps are required in order to define the markers for the segmentation algorithm. Moreover, the segmentation scheme is applied in parallel to an MR image data set through the use of a thread pool, achieving a near real-time execution and making a contribution to solve the time-consuming problem of the HIFU therapy planning.


Author(s):  
David Sanford ◽  
Christoph Schaal

Abstract High-intensity focused ultrasound (HIFU) is used clinically to heat cells therapeutically or to destroy them through heat or cavitation. In homogeneous media, the highest wave amplitudes occur at a predictable focal region. However, HIFU is generally not used in the proximity of bones due to wave absorption and scattering. Ultrasound is passed through the skull in some clinical trials, but the complex geometry of the spine poses a greater targeting challenge and currently prohibits therapeutic ultrasound treatments near the vertebral column. This paper presents a comprehensive experimental study involving shadowgraphy and hydrophone measurements to determine the spatial distribution of pressure amplitudes from induced HIFU waves near vertebrae. First, a bone-like composite plate that is partially obstructing the induced waves is shown to break the conical HIFU form into two regions. Wave images are captured using pulsed laser shadowgraphy, and hydrophone measurements over the same region are compared to the shadowgraphy intensity plots to validate the procedure. Next, shadowgraphy is performed for an individual, clean, ex-vivo feline vertebra. The results indicate that shadowgraphy can be used to determine energy deposition patterns and to determine heating at a specific location. The latter is confirmed through additional temperature measurements. Overall, these laboratory experiments may help determine the efficacy of warming specific nerve cells within mammal vertebrae without causing damage to adjacent tissue.


Sign in / Sign up

Export Citation Format

Share Document