scholarly journals Porous polymer coatings on metal microneedles for enhanced drug delivery

2018 ◽  
Vol 5 (4) ◽  
pp. 171609 ◽  
Author(s):  
Asad Ullah ◽  
Chul Min Kim ◽  
Gyu Man Kim

We present a simple method to coat microneedles (MNs) uniformly with a porous polymer (PLGA) that can deliver drugs at high rates. Stainless steel (SS) MNs of high mechanical strength were coated with a thin porous polymer layer to enhance their delivery rates. Additionally, to improve the interfacial adhesion between the polymer and MNs, the MN surface was modified by plasma treatment followed by dip coating with polyethyleneimine, a polymer with repeating amine units. The average failure load (the minimum force sufficient for detaching the polymer layer from the surface of SS) recorded for the modified surface coating was 25 N, whereas it was 2.2 N for the non-modified surface. Calcein dye was successfully delivered into porcine skin to a depth of 750 µm by the porous polymer-coated MNs, demonstrating that the developed MNs can pierce skin easily without deformation of MNs; additional skin penetration tests confirmed this finding. For visual comparison, rhodamine B dye was delivered using porous-coated and non-coated MNs in gelatin gel which showed that delivery with porous-coated MNs penetrate deeper when compared with non-coated MNs. Finally, lidocaine and rhodamine B dye were delivered in phosphate-buffered saline (PBS) medium by porous polymer-coated and non-coated MNs. For rhodamine B, drug delivery with the porous-coated MNs was five times higher than that with the non-coated MNs, whereas 25 times more lidocaine was delivered by the porous-coated MNs compared with the non-coated MNs.

Polymers ◽  
2019 ◽  
Vol 11 (11) ◽  
pp. 1834 ◽  
Author(s):  
Ullah ◽  
Khan ◽  
Choi ◽  
Kim

: This work demonstrates a simple approach for coating a porous polymer layer on stainless-steel (SS) microneedles characterized by a pH-responsive formulation for self-regulated drug delivery. For many drug-delivery applications, the release of therapeutic agents in an acidic microenvironment is desirable. Acid-sensitive polymers and hydrogels were extensively explored, but easily prepared polymeric microcarriers that combine acid sensitivity and biodegradability are rare. Here, we describe a simple and robust method of coating a porous polymer layer on SS microneedles (MNs) that release a model drug (lidocaine) in a pH-responsive fashion. It was constructed by packing the model drug and a pH-sensitive component (sodium bicarbonate) into the pores of the polymer layer. When this acid-sensitive formulation was exposed to the acidic microenvironment, the consequent reaction of protons (H+) with sodium bicarbonate (NaHCO3) yielded CO2. This effect generated pressure inside the pores of the coating and ruptured the thin polymer membrane, thereby releasing the encapsulated drug. Scanning electron micrographs showed that the pH-sensitive porous polymer-coated MNs exposed to phosphate-buffered saline (PBS) at pH 7.4 were characterized by closed pores. However, MNs exposed to PBS at pH 5.5 consisted of open pores and the thin membrane burst. The in vitro studies demonstrated the pH sensitivity of the drug release from porous polymer-coated MNs. Negligible release was observed for MNs in receiving media at pH 7.4. In contrast, significant release occurred when the MNs were exposed to acidic conditions (pH 5.5). Additionally, comparable results were obtained for drug release in vitro in porcine skin and in PBS. This revealed that our developed pH-responsive porous polymer-coated MNs could potentially be used for the controlled release of drug formulations in an acidic environment. Moreover, the stimuli-responsive drug carriers will enable on-demand controlled release profiles that may enhance therapeutic effectiveness and reduce systemic toxicity.


Molecules ◽  
2021 ◽  
Vol 26 (12) ◽  
pp. 3598
Author(s):  
Nirmal K. Shee ◽  
Hee-Joon Kim

A series of porphyrin triads (1–6), based on the reaction of trans-dihydroxo-[5,15-bis(3-pyridyl)-10,20-bis(phenyl)porphyrinato]tin(IV) (SnP) with six different phenoxy Zn(II)-porphyrins (ZnLn), was synthesized. The cooperative metal–ligand coordination of 3-pyridyl nitrogens in the SnP with the phenoxy Zn(II)-porphyrins, followed by the self-assembly process, leads to the formation of nanostructures. The red-shifts and remarkable broadening of the absorption bands in the UV–vis spectra for the triads in CHCl3 indicate that nanoaggregates may be produced in the self-assembly process of these triads. The emission intensities of the triads were also significantly reduced due to the aggregation. Microscopic analyses of the nanostructures of the triads reveal differences due to the different substituents on the axial Zn(II)-porphyrin moieties. All these nanomaterials exhibited efficient photocatalytic performances in the degradation of rhodamine B (RhB) dye under visible light irradiation, and the degradation efficiencies of RhB in aqueous solution were observed to be 72~95% within 4 h. In addition, the efficiency of the catalyst was not impaired, showing excellent recyclability even after being applied for the degradation of RhB in up to five cycles.


2021 ◽  
Author(s):  
Olugbenga Solomon Bello ◽  
Kayode Adesina Adegoke ◽  
Adejumoke Abosede Inyinbor ◽  
Adewumi Oluwasogo Dada

Materials ◽  
2021 ◽  
Vol 14 (12) ◽  
pp. 3211
Author(s):  
David Donnermeyer ◽  
Sina Schmidt ◽  
Arno Rohrbach ◽  
Johannes Berlandi ◽  
Sebastian Bürklein ◽  
...  

The aim of this study was to investigate the suitability of rhodamine B dye staining of an epoxy resin sealer (AH Plus) and calcium-silicate-based sealers (Total Fill BC Sealer, BioRoot RCS) to represent the penetration depth of the sealers into dentinal tubules after root canal obturation. In a three-step process, (1) leaching of rhodamine B from sealers into a buffer solution, (2) passive penetration of leached rhodamine B into dentinal tubules, and (3) conformity of rhodamine B penetration assessed by confocal laser scanning microscopy (CLSM), and sealer penetration assessed by scanning electron microscopy (SEM), in root-canal-filled teeth, were evaluated. Rhodamine B dye massively leached out of Total Fill BC Sealer and BioRoot RCS into the phosphate-buffered saline (PBS). A pinkish coloration of AH Plus was found after contact with PBS. Leached rhodamine B dye passively penetrated dentinal tubules from all three sealers when placed on root dentin. No correlation was observed between sealer penetration in SEM and rhodamine B penetration in CLSM. Staining of sealers using rhodamine B is an inadequate method with which to evaluate sealer penetration depth into dentinal tubules, as it overestimates the penetration of sealers into root dentin tubules.


Heliyon ◽  
2021 ◽  
Vol 7 (4) ◽  
pp. e06851
Author(s):  
Usha Jinendra ◽  
Dinesh Bilehal ◽  
B.M. Nagabhushana ◽  
Avvaru Praveen Kumar

Water ◽  
2021 ◽  
Vol 13 (11) ◽  
pp. 1522
Author(s):  
Salma Jabeen ◽  
Muhammad Sufaid Khan ◽  
Rozina Khattak ◽  
Ivar Zekker ◽  
Juris Burlakovs ◽  
...  

The catalytic activity of Pd/ZrO2 was studied in terms of the degradation of rhodamine-B dye in the presence of hydrogen peroxide. Pd/ZrO2 was prepared by impregnation method, calcined at 750 °C and characterized by XRD, SEM and EDX. The catalyst showed good catalytic activity for dye degradation at 333 K, using 0.05 g of the catalyst during 5 h. The reaction kinetics followed the pseudo-first order kinetics. The Freundlich, Langmuir and Temkin isotherms were applied to the data and the best fit was obtained with Freundlich isotherm. Thermodynamic parameters, like ΔH, ΔG and ΔS were also calculated. The negative values of ΔH (−291.406 KJ/mol) and Gibbs free energy (ΔG) showed the exothermic and spontaneous nature of the process. The positive ΔS (0.04832 KJ/mol K) value showed suitable affinity of catalyst for dye degradation. The catalyst was very stable, active and was easily separated from the reaction mixture by filtration. It can be concluded from the results that the prepared catalyst could be effectively used in dyes degradation/removal from water subjected to further validation and use for various dyes.


2019 ◽  
Vol 58 (3) ◽  
pp. 134-140 ◽  
Author(s):  
Eduarda Medran Rangel ◽  
Caio César Nogueira de Melo ◽  
Fernando Machado Machado

Sign in / Sign up

Export Citation Format

Share Document