Use of Continuous Electrical Impedance Measurement for Accurate Nerve Block in Rabbits

Pain Medicine ◽  
2021 ◽  
Author(s):  
Chiyo Ootaki ◽  
Yo Kobayashi ◽  
Yuki Koyama

Abstract Objective To perform an effective and safe nerve block, the needle must be placed near the target nerve while avoiding nerve damage. Our objective was to conduct an animal study to determine whether changes in electrical impedance (EI) could be used to guide the needle and achieve a safe and accurate nerve block. Methods We measured the EI of rabbit tissues during ultrasound-guided sciatic nerve block using a bipolar needle via the in-plane needle approach. The EI values and needle track on the ultrasound monitor were video-recorded. When there was a change in the EI, the needle advancement was stopped, and a stained anesthetic was injected. Subsequently, the animals were euthanized, and the anesthetic-stained tissue was examined via dissection, while the other tissue was preserved at –80°C for microscopic analysis. Results The EI remained stable as the needle advanced through the muscle (extraneural); however, it markedly decreased when the needle tip contacted the nerve or slightly punctured the epineurium (paraneural). The mean extra- and paraneural EIs were 4.92 ± 1.31 kΩ (range, 2.39–9.67 kΩ) and 2.86 ± 0.96 kΩ (range, 1.66–5.13 kΩ), respectively. Examination of the dissections and cryostat sections showed anesthetic delivery around the nerve. Conclusions EI values differed between extra- and paraneural sites, and monitoring these values allowed prediction of the needle tip location with respect to the target nerve. Real-time EI measurement could improve the nerve block.

Author(s):  
Oliver Power ◽  
Adam Ziolek ◽  
Andreas Elmholdt Christensen ◽  
Andrei Pokatilov ◽  
Anca Nestor ◽  
...  

The core objective of EMPIR project 17RPT04 VersICaL is to improve the European measurement infrastructure for electrical impedance, with particular emphasis on the capabilities of developing NMIs and calibration centres. The project will seek to exploit the results of existing research on digital impedance bridges (DIBs) by designing, constructing and validating simple, affordable versions suitable to realise the impedance scale in the range 1 nF to 10 μF and 1 mH to 10 H with relative uncertainties in the range 10-5 to 10-6. The first results of the research project, including the bridge designs and details of a polyphase digitally synthesized multichannel source capable of providing voltage outputs of precise ratio and phase are presented.


Author(s):  
Richard Galos ◽  
Xin Li

Electrical Impedance Measurement of PZT Nanofiber sensors are performed and material properties including resistivity and dielectric constant are derived from the measurements. Nanofibers formed by electro-spinning with diameters ranging from 10 to 150 nm were collected and integrated into sensors using microfabrication techniques. The nanosensor impedance was extremely high at low frequencies and special matching circuitry was fabricated to detect output. The resulting impedance measurements are also compared with those of individual nanofibers that were tested using Scanning Conductive Microscopy (SCM) and Conductive AFM.


2019 ◽  
Vol 91 (9) ◽  
pp. 1481-1491 ◽  
Author(s):  
Leszek Kubisz ◽  
Dorota Hojan-Jezierska ◽  
Maria Szewczyk ◽  
Anna Majewska ◽  
Weronika Kawałkiewicz ◽  
...  

Abstract Structural and chemical alterations in living tissue are reflected in electrical impedance changes. However, due to the complexity of skin structure, the relation between electrical parameters and physiological/pathological conditions is difficult to establish. The impedance dispersion reflects the clinical status of the examined skin tissue and, therefore, it is frequently used in a non-invasive evaluation of exposing skin to various factors. The method has been used to assess the effect of the fish collagen on the skin of patients suffering from the leg ulcer. Therefore, from a number of different approaches to skin electrical impedance dispersion, the one considered to be safe was selected and applied. This paper presents a short review of different technical approaches to in vivo electrical impedance measurements, as well as an analysis of the results and the effect of fish collagen locally administered on human skin.