Commentary: Effect of Carotid Siphon Anatomy on Aneurysm Occlusion After Flow Diversion for Treatment of Internal Carotid Artery Aneurysms

2018 ◽  
Vol 17 (2) ◽  
pp. E45-E46
Author(s):  
Visish M Srinivasan ◽  
Peter Kan
2020 ◽  
Vol 26 (4) ◽  
pp. 468-475 ◽  
Author(s):  
Ahmed E Hussein ◽  
Meghana Shownkeen ◽  
Andre Thomas ◽  
Christopher Stapleton ◽  
Denise Brunozzi ◽  
...  

Objective Indications for the treatment of cerebral aneurysms with flow diversion stents are expanding. The current aneurysm occlusion rate at six months ranges between 60 and 80%. Predictability of complete vs. partial aneurysm occlusion is poorly defined. Here, we evaluate the angiographic contrast time-density as a predictor of aneurysm occlusion rate at six months’ post-flow diversion stents. Methods Patients with unruptured cerebral aneurysms proximal to the internal carotid artery terminus treated with single flow diversion stents were included. 2D parametric parenchymal blood flow software (Siemens-Healthineers, Forchheim, Germany) was used to calculate contrast time-density within the aneurysm and in the proximal adjacent internal carotid artery. The area under the curve ratio between the two regions of interests was assessed at baseline and after flow diversion stents deployment. The area under the curve ratio between completely vs. partially occluded aneurysms at six months’ follow-up was compared. Results Thirty patients with 31 aneurysms were included. Mean aneurysm diameter was 8 mm (range 2–28 mm). Complete occlusion was obtained in 19 aneurysms. Younger patients ( P = 0.006) and smaller aneurysms ( P = 0.046) presented higher chance of complete obliteration. Incomplete occlusion of the aneurysm was more likely if the area under the curve contrast time-density ratio showed absolute ( P = 0.001) and relative percentage ( P = 0.001) decrease after flow diversion stents deployment. Area under ROC curve was 0.85. Conclusion Negative change in the area under the curve ratio indicates less contrast stagnation in the aneurysm and lower chance of occlusion. These data provide a real-time analysis after aneurysm treatment. If validated in larger datasets, this can prompt input to the surgeon to place a second flow diversion stents.


Neurosurgery ◽  
2016 ◽  
Vol 79 (5) ◽  
pp. E634-E638 ◽  
Author(s):  
Marcus D. Mazur ◽  
Philipp Taussky ◽  
Joel D. MacDonald ◽  
Min S. Park

Abstract BACKGROUND AND IMPORTANCE: As the use of flow-diverting stents (FDSs) for intracranial aneurysms expands, a small number of case reports have described the successful treatment of blister aneurysms of the internal carotid artery with flow diversion. Blister aneurysms are uncommon and fragile lesions that historically have high rates of morbidity and mortality despite multiple treatment strategies. We report a case of rebleeding after treatment of a ruptured blister aneurysm with deployment of a single FDS. CLINICAL PRESENTATION: A 29-year-old man presented with subarachnoid hemorrhage and a ruptured dorsal variant internal carotid artery aneurysm. Despite a technically successful treatment with a single FDS, a second catastrophic hemorrhage occurred during the course of his hospitalization. CONCLUSION: This case highlights the risk of hemorrhage during the period after deployment of a single FDS. Ruptured aneurysms, especially of the blister type, are at risk for rehemorrhage while the occlusion remains incomplete after flow diversion.


2017 ◽  
Vol 23 (6) ◽  
pp. 614-619 ◽  
Author(s):  
Jeremy J Heit ◽  
Nicholas A Telischak ◽  
Huy M Do ◽  
Robert L Dodd ◽  
Gary K Steinberg ◽  
...  

Background Subarachnoid hemorrhage (SAH) secondary to rupture of a blister aneurysm (BA) results in high morbidity and mortality. Endovascular treatment with the pipeline embolization device (PED) has been described as a new treatment strategy for these lesions. We present the first reported case of PED retraction and foreshortening after treatment of a ruptured internal carotid artery (ICA) BA. Case description A middle-aged patient presented with SAH secondary to ICA BA rupture. The patient was treated with telescoping PED placement across the BA. After 5 days from treatment, the patient developed a new SAH due to re-rupture of the BA. Digital subtraction angiography revealed an increase in caliber of the supraclinoid ICA with associated retraction and foreshortening of the PED that resulted in aneurysm uncovering and growth. Conclusions PED should be oversized during ruptured BA treatment to prevent device retraction and aneurysm regrowth. Frequent imaging follow up after BA treatment with PED is warranted to ensure aneurysm occlusion.


2020 ◽  
Vol 33 (4) ◽  
pp. 297-305
Author(s):  
Mostafa Mahmoud ◽  
Ahmed Farag ◽  
Mostafa Farid ◽  
Ahmed Elserwi ◽  
Amr Abdelsamad ◽  
...  

Introduction The treatment of aneurysms in the internal carotid bifurcation region (ICABR), including aneurysms of the true internal carotid artery (ICA) terminus, those inclined on the proximal A1 or M1 segments or at the most distal pre-bifurcation (ICA) segment, is often challenging in microsurgical clipping and endovascular surgery. Few reports had discussed flow diversion as a therapeutic option for this group. Methods This was a retrospective study analysing flow diversion in treating ICABR aneurysms. Seven patients harbouring eight aneurysms in the ICABR were treated with flow diversion. Five aneurysms were inclined on the proximal A1 segment, and three were located at the most distal pre-bifurcation segment. Patients’ demographics, presentation, procedure technical description, angiographic and clinical follow-up were recorded. PubMed and Ovid MEDLINE were also reviewed for articles published in English, including case series or case reports, for ICABR aneurysms treated with flow diverters. Results All patients except one underwent angiographic follow-up. The Karman–Byrne occlusion scale was used to determine the occlusion rate. All six patients with documented angiographic follow-up had a class IV occlusion score. No permanent or transient neurological or non-neurological complications were encountered in this study. Conclusion Treating ICABR aneurysms using flow diversion is feasible, with a promising angiographic occlusion rate. Further studies are needed to analyse long-term clinical and angiographic results.


2020 ◽  
Vol 134 ◽  
pp. 580-583 ◽  
Author(s):  
Matthew T. Bender ◽  
David A. Zarrin ◽  
Bowen Jiang ◽  
Jessica K. Campos ◽  
Li-Mei Lin ◽  
...  

2018 ◽  
Vol 25 (1) ◽  
pp. 4-11 ◽  
Author(s):  
Anna Luisa Kühn ◽  
Peter Kan ◽  
Visish Srinivasan ◽  
David E Rex ◽  
Katyucia de Macedo Rodrigues ◽  
...  

Background To evaluate the feasibility and efficacy of the pipeline embolization device in the treatment of unruptured intracranial mirror segment aneurysms. Methods Out of a total of 338 subjects, 14 were identified harboring a total of 32 internal carotid artery mirror segment aneurysms that were treated with the pipeline embolization device and were consecutively enrolled into our study. We collected data on patient demographics, modified Rankin scale (mRS) at admission, aneurysm characteristics, clinical outcome at discharge, 3–9 and at 12–18 months as well as angiography results at follow-up. Results Patients’ mean age was 52.9 years; baseline mRS was 0 in all subjects. Pipeline embolization device placement was successful in all cases. Post-treatment mRS remained 0 in 13/14 patients. One patient experienced a small intraparenchymal hemorrhage and subarachnoid hemorrhage, associated with a frontoparietal infarction resulting in right upper extremity weakness and aphasia (post-treatment mRS 3). His mRS evaluation remained stable at the 3–9-month follow-up. Three to 9-month follow-up angiography (13/14 subjects) showed complete aneurysm occlusion in 24/30 aneurysms (80%), near complete and partial occlusion in three of 30 (10%) aneurysms each. At the 9-month follow-up, one patient experienced a complete occlusion of the anterior temporal artery branch but did not present with any clinical deficits. No mRS changes were encountered over a median 6-month follow-up period. Mid-term follow-up angiography (12–18 months) available in eight of 14 subjects showed complete aneurysm occlusion in all patients. Mild intimal hyperplasia was observed in one patient. Conclusions Flow diversion technology can be used for the treatment of unruptured mirror segment aneurysms in selected patients.


2019 ◽  
Vol 10 (01) ◽  
pp. 142-144 ◽  
Author(s):  
Ching-Jen Chen ◽  
M. Rao Patibandla ◽  
Min S. Park ◽  
M. Yashar Kalani

ABSTRACTDespite the widespread use of the pipeline embolization device (PED), no complete aneurysm regrowth after its placement has been reported in the literature. We report the first case of aneurysm regrowth after the initial follow-up angiography demonstrating near-complete occlusion of the aneurysm and remodeling of the vessel with on-label PED use for a large 20 mm × 24 mm × 22 mm (width × depth × height) cavernous segment internal carotid artery (ICA) aneurysm. The patient was treated with two overlapping PED (4.5 mm × 20 mm and 5 mm × 20 mm). Follow-up angiogram at 4 months after treatment demonstrated remodeling of the ICA with a small residual component measuring approximately 7 mm × 8 mm × 7 mm. However, at 10 months after treatment, there was a complete regrowth of the aneurysm with interval growth, now measuring 25 mm × 28 mm × 18 mm. Despite the high aneurysm occlusion rates reported with the PED, persistent aneurysm filling and aneurysm regrowth, although rare, should not be overlooked.


Sign in / Sign up

Export Citation Format

Share Document