scholarly journals Hand-Held Stereovision System for Image Updating in Open Spine Surgery

2020 ◽  
Vol 19 (4) ◽  
pp. 461-470
Author(s):  
Xiaoyao Fan ◽  
Maxwell S Durtschi ◽  
Chen Li ◽  
Linton T Evans ◽  
Songbai Ji ◽  
...  

Abstract BACKGROUND Image guidance in open spinal surgery is compromised by changes in spinal alignment between preoperative images and surgical positioning. We evaluated registration of stereo-views of the surgical field to compensate for vertebral alignment changes. OBJECTIVE To assess accuracy and efficiency of an optically tracked hand-held stereovision (HHS) system to acquire images of the exposed spine during surgery. METHODS Standard midline posterior approach exposed L1 to L6 in 6 cadaver porcine spines. Fiducial markers were placed on each vertebra as “ground truth” locations. Spines were positioned supine with accentuated lordosis, and preoperative computed tomography (pCT) was acquired. Spines were re-positioned in a neutral prone posture, and locations of fiducials were acquired with a tracked stylus. Intraoperative stereovision (iSV) images were acquired and 3-dimensional (3D) surfaces of the exposed spine were reconstructed. HHS accuracy was assessed in terms of distances between reconstructed fiducial marker locations and their tracked counterparts. Level-wise registrations aligned pCT with iSV to account for changes in spine posture. Accuracy of updated computed tomography (uCT) was assessed using fiducial markers and other landmarks. RESULTS Acquisition time for each image pair was <1 s. Mean reconstruction time was <1 s for each image pair using batch processing, and mean accuracy was 1.2 ± 0.6 mm across 6 cases. Mean errors of uCT were 3.1 ± 0.7 and 2.0 ± 0.5 mm on the dorsal and ventral sides, respectively. CONCLUSION Results suggest that a portable HHS system offers potential to acquire accurate image data from the surgical field to facilitate surgical navigation during open spine surgery.

2021 ◽  
Author(s):  
Thomas Linsenmann ◽  
Andrea Cattaneo ◽  
Alexander März ◽  
Judith Weiland ◽  
Christian Stetter ◽  
...  

Abstract Purpose: Mobile 3-dimensional fluoroscopes are available in a number of neurosurgical departments and can be used in combination with simple image post processing to depict cerebral vessels. In preparation of stereotactic surgery, preoperative Computed Tomography (CT) may be required for image fusion. Contrast CT may be of further advantage for image fusion as it regards the vessel anatomy in trajectory planning. Time-consuming in-hospital transports are necessary for this purpose. Mobile 3D-fluoroscopes may be used to generate a CT equal preoperative data set without an in-hospital transport. This study was performed to determine the feasibility and image quality of intraoperative 3-dimensional fluoroscopy with intravenous contrast administration.Methods: 6 patients were included in this feasibility study. Their heads were fixed in a radiolucent Mayfield clamp. A rotational fluoroscopy scan was performed with 50 mL iodine contrast agent. The image data sets were merged with the existing MRI images at a planning station and visually evaluated by two observer. The operation times were compared between the frame-based and frameless systems (“skin-to-skin” and “OR entry to exit”)Results: No adverse effects were observed. The entire procedure from fluoroscope positioning to the transfer to the planning station took 5 to 6 minutes with an image acquisition time of 24 seconds. In 5 of 6 cases, the fused imaging was able to reproduce the vascular anatomy accurately and in good quality. Both time end-points were significantly shorter compared to frame-based interventions.Conclusion: The images could easily be transferred to the planning and navigation system and were successfully merged with the MRI data set. The procedure can be completely integrated into the surgical workflow. Preoperative CT imaging or transport under anaesthesia may even be replaced by this technique in the future. Furthermore, hemorrhages can be successfully visualized intraoperatively and might prevent time delays in emergencies.


2021 ◽  
Vol 21 (1) ◽  
Author(s):  
Thomas Linsenmann ◽  
Andrea Cattaneo ◽  
Alexander März ◽  
Judith Weiland ◽  
Christian Stetter ◽  
...  

Abstract Background Mobile 3-dimensional fluoroscopes are an integral part of modern neurosurgical operating theatres and can also be used in combination with free available image post processing to depict cerebral vessels. In preparation of stereotactic surgery, preoperative Computed Tomography (CT) may be required for image fusion. Contrast CT may be of further advantage for image fusion as it regards the vessel anatomy in trajectory planning. Time-consuming in-hospital transports are necessary for this purpose. Mobile 3D-fluoroscopes may be used to generate a CT equal preoperative data set without an in-hospital transport. This study was performed to determine the feasibility and image quality of intraoperative 3-dimensional fluoroscopy with intravenous contrast administration in combination with stereotactical procedures. Methods 6 patients were included in this feasibility study. After fixation in a radiolucent Mayfield clamp a rotational fluoroscopy scan was performed with 50 mL iodine contrast agent. The image data sets were merged with the existing MRI images at a planning station and visually evaluated by two observer. The operation times were compared between the frame-based and frameless systems (“skin-to-skin” and “OR entry to exit”). Results The procedure proves to be safe. The entire procedure from fluoroscope positioning to the transfer to the planning station took 5–6 min with an image acquisition time of 24 s. In 5 of 6 cases, the fused imaging was able to reproduce the vascular anatomy accurately and in good quality. Both time end-points were significantly shorter compared to frame-based interventions. Conclusion The images could easily be transferred to the planning and navigation system and were successfully merged with the MRI data set. The procedure can be completely integrated into the surgical workflow. Preoperative CT imaging or transport under anaesthesia may even be replaced by this technique in the future. Furthermore, hemorrhages can be successfully visualized intraoperatively and might prevent time delays in emergencies.


Author(s):  
R.D. Leapman ◽  
S.B. Andrews

Elemental mapping of biological specimens by electron energy loss spectroscopy (EELS) can be carried out both in the scanning transmission electron microscope (STEM), and in the energy-filtering transmission electron microscope (EFTEM). Choosing between these two approaches is complicated by the variety of specimens that are encountered (e.g., cells or macromolecules; cryosections, plastic sections or thin films) and by the range of elemental concentrations that occur (from a few percent down to a few parts per million). Our aim here is to consider the strengths of each technique for determining elemental distributions in these different types of specimen.On one hand, it is desirable to collect a parallel EELS spectrum at each point in the specimen using the ‘spectrum-imaging’ technique in the STEM. This minimizes the electron dose and retains as much quantitative information as possible about the inelastic scattering processes in the specimen. On the other hand, collection times in the STEM are often limited by the detector read-out and by available probe current. For example, a 256 x 256 pixel image in the STEM takes at least 30 minutes to acquire with read-out time of 25 ms. The EFTEM is able to collect parallel image data using slow-scan CCD array detectors from as many as 1024 x 1024 pixels with integration times of a few seconds. Furthermore, the EFTEM has an available beam current in the µA range compared with just a few nA in the STEM. Indeed, for some applications this can result in a factor of ~100 shorter acquisition time for the EFTEM relative to the STEM. However, the EFTEM provides much less spectral information, so that the technique of choice ultimately depends on requirements for processing the spectrum at each pixel (viz., isolated edges vs. overlapping edges, uniform thickness vs. non-uniform thickness, molar vs. millimolar concentrations).


2019 ◽  
Vol 11 (10) ◽  
pp. 1157 ◽  
Author(s):  
Jorge Fuentes-Pacheco ◽  
Juan Torres-Olivares ◽  
Edgar Roman-Rangel ◽  
Salvador Cervantes ◽  
Porfirio Juarez-Lopez ◽  
...  

Crop segmentation is an important task in Precision Agriculture, where the use of aerial robots with an on-board camera has contributed to the development of new solution alternatives. We address the problem of fig plant segmentation in top-view RGB (Red-Green-Blue) images of a crop grown under open-field difficult circumstances of complex lighting conditions and non-ideal crop maintenance practices defined by local farmers. We present a Convolutional Neural Network (CNN) with an encoder-decoder architecture that classifies each pixel as crop or non-crop using only raw colour images as input. Our approach achieves a mean accuracy of 93.85% despite the complexity of the background and a highly variable visual appearance of the leaves. We make available our CNN code to the research community, as well as the aerial image data set and a hand-made ground truth segmentation with pixel precision to facilitate the comparison among different algorithms.


2021 ◽  
Vol 20 ◽  
pp. 153303382110101
Author(s):  
Thet-Thet Lwin ◽  
Akio Yoneyama ◽  
Hiroko Maruyama ◽  
Tohoru Takeda

Phase-contrast synchrotron-based X-ray imaging using an X-ray interferometer provides high sensitivity and high spatial resolution, and it has the ability to depict the fine morphological structures of biological soft tissues, including tumors. In this study, we quantitatively compared phase-contrast synchrotron-based X-ray computed tomography images and images of histopathological hematoxylin-eosin-stained sections of spontaneously occurring rat testicular tumors that contained different types of cells. The absolute densities measured on the phase-contrast synchrotron-based X-ray computed tomography images correlated well with the densities of the nuclear chromatin in the histological images, thereby demonstrating the ability of phase-contrast synchrotron-based X-ray imaging using an X-ray interferometer to reliably identify the characteristics of cancer cells within solid soft tissue tumors. In addition, 3-dimensional synchrotron-based phase-contrast X-ray computed tomography enables screening for different structures within tumors, such as solid, cystic, and fibrous tissues, and blood clots, from any direction and with a spatial resolution down to 26 μm. Thus, phase-contrast synchrotron-based X-ray imaging using an X-ray interferometer shows potential for being useful in preclinical cancer research by providing the ability to depict the characteristics of tumor cells and by offering 3-dimensional information capabilities.