scholarly journals SM-3 Noise Reduction Method Based on Machine Learnings for Electron Holography

Microscopy ◽  
2019 ◽  
Vol 68 (Supplement_1) ◽  
pp. i7-i7
Author(s):  
Yusuke Asari
Microscopy ◽  
2020 ◽  
Vol 69 (2) ◽  
pp. 123-131 ◽  
Author(s):  
Yoshihiro Midoh ◽  
Koji Nakamae

Abstract We try to improve the limit of the phase estimation of the interference fringe at low electron dose levels in electron holography by a noise reduction method. In this paper, we focus on unsupervised approaches to apply it to electron beam-sensitive and unknown samples and describe an overview of denoising methods used widely in image processing, such as wiener filter, total variation denoising, nonlocal mean filters and wavelet thresholding. We compare the wavelet hidden Markov model (WHMM) denoising that we have studied so far with the other conventional noise reduction methods. We evaluate the denoise performance of each method using the peak signal-to-noise ratio between noise-free and the target holograms (noisy or denoised holograms) and the root mean-square error (RMSE) between the true phase of the fringe and the measured phase by the discrete Fourier transform phase estimator. We show the denoised holograms for simulation and experimental data by using each noise reduction method and then discuss evaluation indexes obtained from these denoised holograms. From experimental results, it can be seen that the WHMM denoising can reduce the RMSE of fringe phase to about 1/4.5 for noisy simulation holograms and it has stable and good performance for noise reduction of observed holograms with various image qualities.


2021 ◽  
Author(s):  
Zonghan Sun ◽  
Jie Tian ◽  
Grzegorz Liśkiewicz ◽  
Zhaohui Du ◽  
Hua Ouyang

Abstract A noise reduction method for axial flow fans using a short inlet duct is proposed. The pattern of noise reduction imposed by the short inlet duct on the axial flow cooling fan under variable working conditions was experimentally and numerically examined. A 2-cm inlet duct was found to reduce tonal noise. As the tip Mach number of the fan increased from 0.049 to 0.156, the reduction in the total average sound pressure level at 1 m from the fan increased from 0.8 dB(A) to 4.3 dB(A), and further achieved 4.8 dB(A) when a 1-cm inlet duct was used. The steady computational fluid dynamics (CFD) showed that the inlet duct has little effect on the aerodynamic performance of the fan. The results of the full passage unsteady calculation at the maximum flow rate showed that the duct has a significant influence on the suction vortexes caused by the inlet flow non-uniformity. The suction vortexes move upstream to weaken the interaction with the rotor blades, which significantly reduces the pulsating pressure on the blades. The sound pressure level (SPL) at the blade passing frequency (BPF) contributed by the thrust force was calculated to reduce by 36 dB at a 135° observer angle, reflecting the rectification effect of the duct on the non-uniform inlet flow and the improvement in characteristics of the noise source. The proper orthogonal decomposition (POD) of the static pressure field on the blades verified that the main spatial mode is more uniformly distributed due to the duct, and energy owing to the rotor-inlet interaction decreases. A speed regulation strategy for the cooling fan with short inlet duct is proposed, which provides guidance for the application of this noise reduction method.


2013 ◽  
Vol 06 (02) ◽  
pp. 1350009 ◽  
Author(s):  
OLEG O. MYAKININ ◽  
DMITRY V. KORNILIN ◽  
IVAN A. BRATCHENKO ◽  
VALERIY P. ZAKHAROV ◽  
ALEXANDER G. KHRAMOV

In this paper, the new method for OCT images denoizing based on empirical mode decomposition (EMD) is proposed. The noise reduction is a very important process for following operations to analyze and recognition of tissue structure. Our method does not require any additional operations and hardware modifications. The basics of proposed method is described. Quality improvement of noise suppression on example of edge-detection procedure using the classical Canny's algorithm without any additional pre- and post-processing operations is demonstrated. Improvement of raw-segmentation in the automatic diagnostic process between a tissue and a mesh implant is shown.


2013 ◽  
Vol 32 (4) ◽  
pp. 1839-1857 ◽  
Author(s):  
Mehdi Nasri ◽  
Saeid Saryazdi ◽  
Hossein Nezamabadi-pour

Sign in / Sign up

Export Citation Format

Share Document