scholarly journals Asymptomatic cerebral lesions during pulmonary vein isolation under uninterrupted oral anticoagulation

EP Europace ◽  
2012 ◽  
Vol 15 (3) ◽  
pp. 325-331 ◽  
Author(s):  
Martin Martinek ◽  
Elisabeth Sigmund ◽  
Christine Lemes ◽  
Michael Derndorfer ◽  
Josef Aichinger ◽  
...  
EP Europace ◽  
2021 ◽  
Vol 23 (Supplement_3) ◽  
Author(s):  
P Loh ◽  
MHA Groen ◽  
K Taha ◽  
FHM Wittkampf ◽  
PA Doevendans ◽  
...  

Abstract Funding Acknowledgements Type of funding sources: Private company. Main funding source(s): Abbott Background Irreversible electroporation (IRE) is a promising new non-thermal ablation technology for pulmonary vein isolation (PVI) in patients with atrial fibrillation (AF). First in human studies demonstrated the feasibility and safety of IRE PVI. Objective Further investigate the safety of IRE PVI. Methods Twenty patients with symptomatic AF underwent IRE PVI under conscious sedation. Oral anticoagulation was uninterrupted and heparin was administered to maintain activated clotting time at 300-350 seconds. Non-arcing, non-barotraumatic 6 ms, 200 J IRE applications were delivered via a custom non-steerable 8 F, 14-polar circular IRE ablation catheter with a variable hoop diameter (16-27 mm). Voltage mapping  of the left atrium and the PVs was performed before and after ablation with a conventional circular mapping catheter. For both catheters a single transseptal access (8 F introducer, Agilis NxTTM) was used. Adenosine testing was performed after a 30-minute waiting period. On day 1 after ablation, patients underwent esophagoscopy and brain MRI (DWI/FLAIR). If abnormalities were detected, examinations were repeated in due time. Results In 20 patients, all 80 PVs could be successfully isolated with a mean of 11,8 ± 1,4 IRE applications per patient. Average time from first to last IRE application was 22 ± 5 minutes, total procedure duration was 107 ± 13 minutes and total fluoroscopy time was 23 ± 5 minutes. One PV reconnection occurred during adenosine testing, re-isolation was achieved with 2 additional IRE pulses. No periprocedural complications were observed. Brain MRI on day 1 after ablation showed punctate asymptomatic lesions in 3/20 patients (15%). At follow-up MRI the lesion disappeared in 1 patient while in the other 2 patients 1 lesion persisted. Esophagoscopy on day 1 showed an asymptomatic esophageal lesion in 1/20 patients (5%), at repeat esophagoscopy on day 22 the lesion had resolved completely. Conclusion Acute electrical PV isolation could be achieved safely and rapidly by IRE ablation under conscious sedation in 20 patients with symptomatic AF. Acute silent cerebral lesions were detected in 3/20 patients (15%) and may be due to ablation or to changes of therapeutic and diagnostic catheters over a single transseptal access.


2017 ◽  
Vol 2 (2) ◽  
pp. 146 ◽  
Author(s):  
Sara Själander ◽  
Fredrik Holmqvist ◽  
J. Gustav Smith ◽  
Pyotr G. Platonov ◽  
Milos Kesek ◽  
...  

2019 ◽  
Vol 30 (6) ◽  
pp. 877-885 ◽  
Author(s):  
Boris Schmidt ◽  
Gábor Széplaki ◽  
Bela Merkely ◽  
Josef Kautzner ◽  
Vincent Driel ◽  
...  

2015 ◽  
Vol 15 (2) ◽  
pp. 110-114
Author(s):  
Christian Fastner ◽  
Michael Behnes ◽  
Uzair Ansari ◽  
Ibrahim Akin

Author(s):  
Marc Kottmaier ◽  
Leonie Förschner ◽  
Nada Harfoush ◽  
Felix Bourier ◽  
Sarah Mayr ◽  
...  

Background High power short duration (HPSD) radiofrequency-ablation (RFA) is highly efficient and safe while reducing procedure and RF time in pulmonary vein isolation (PVI). The QDot-catheter is a novel contact-force ablation catheter that allows automated flow and power adjustments depending on the local tissue temperature to maintain a target temperature during 90watts/4seconds lesions. We analysed intraprocedural data and periprocedural safety using the QDot-catheter in patients undergoing PVI for paroxysmal atrial fibrillation (PAF). Methods We included n=48 patients undergoing PVI with the QDot-catheter with a temperature controlled HPSD ablation mode with 90watts/4seconds (TC-HPSD). If focal reconnection occurred besides repeat ablation the ablation mode was changed to 50watts/15seconds (QMode). N=23 patients underwent cerebral MRI to detect silent cerebral lesions. Results Mean RF-time was 8.1+/-2.8min, procedure-duration was 84.5+/-30min. The overall maximal measured catheter-tip temperature was 52.0°C +/- 4.6°C, mean overall applied current was 871mA +/-44mA and over all applied energy was 316J +/-47J. The mean local impedance-drop was 12.1 +/- 2.4 Ohms. During Adenosine challenge n=14 (29%) patients showed dormant conduction. A total of n=24 steam pops were detected in n=18 patients (39.1%), while no pericardial tamponade occurred. No periprocedural thromboembolic complications occurred, while n=4 patients (17.4%) showed silent cerebral lesion. Conclusion TC-HPSD ablation with 90watts/4seconds using the QDot-catheter led to a reduction of procedure and RF time, while no major complications occurred. Despite optimized temperature control and power adjustment steam pops occurred in a rather high number of patients, while none of them lead to tamponade or to clinical or neurological deficits.


EP Europace ◽  
2016 ◽  
Vol 18 (suppl_1) ◽  
pp. i90-i90
Author(s):  
Piotr Lodzinski ◽  
Sonia Borodzicz ◽  
Michal Peller ◽  
Paweł Balsam ◽  
Krzysztof Ozieranski ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document