scholarly journals Long-term follow-up after transatrial–transpulmonary repair of tetralogy of Fallot: influence of timing on outcome

2019 ◽  
Vol 57 (4) ◽  
pp. 635-643
Author(s):  
Eva van den Bosch ◽  
Ad J J C Bogers ◽  
Jolien W Roos-Hesselink ◽  
Arie P J van Dijk ◽  
Marie H E J van Wijngaarden ◽  
...  

Abstract OBJECTIVES Our goal was to report the long-term serial follow-up after transatrial–transpulmonary repair of tetralogy of Fallot (TOF) and to describe the influence of the timing of the repair on outcome. METHODS We included all patients with TOF who had undergone transatrial–transpulmonary repair between 1970 and 2012. Records were reviewed for patient demographics, operative details and events during the follow-up period (death, pulmonary valve replacement, cardiac reinterventions and hospitalization/intervention for arrhythmias). In patients with elective early primary repair of TOF after 1990, a subanalysis of the optimal timing of TOF repair was performed. RESULTS A total of 453 patients were included (63% male patients; 65% had transannular patch); 261 patients underwent primary elective repair after 1990. The median age at TOF repair was 0.7 years (25th–75th percentile 0.3–1.3) and decreased from 1.7 to 0.4 years from before 1990 to after 2000, respectively (P < 0.001). The median follow-up duration after TOF repair was 16.8 years (9.6–24.7). Events developed in 182 (40%) patients. In multivariable analysis, early repair of TOF (<6 months) [hazard ratio (HR) 3.06; P < 0.001] and complications after TOF repair (HR 2.18; P = 0.006) were found to be predictive for an event. In a subanalysis of the primary repair of TOF after 1990, the patients (n = 125) with elective early repair (<6 months) experienced significantly worse event-free survival compared to patients who had elective repair later (n = 136). In multivariable analysis, early repair (HR 3.00; P = 0.001) and postoperative complications (HR 2.12; P = 0.010) were associated with events in electively repaired patients with TOF. CONCLUSIONS Transatrial–transpulmonary repair of TOF before the age of 6 months may be associated with more events during the long-term follow-up period.

ESC CardioMed ◽  
2018 ◽  
pp. 814-818
Author(s):  
Robert Yates

Primary repair is now the favoured approach for most patients with tetralogy of Fallot, and has excellent results. Pulmonary regurgitation is the major management issue during long-term follow-up, and late pulmonary valve replacement by surgery or percutaneous approach may be required.


2014 ◽  
Vol 114 (6) ◽  
pp. 901-908 ◽  
Author(s):  
Anna Sabate Rotes ◽  
Benjamin W. Eidem ◽  
Heidi M. Connolly ◽  
Crystal R. Bonnichsen ◽  
Jordan K. Rosedahl ◽  
...  

Author(s):  
Simone Ghiselli ◽  
Cristina Carro ◽  
Nicola Uricchio ◽  
Giuseppe Annoni ◽  
Stefano M Marianeschi

Abstract OBJECTIVES Chronic pulmonary valve (PV) regurgitation is a common late sequela after repair of congenital heart diseases like tetralogy of Fallot or pulmonary stenosis, leading to right ventricular dilatation and failure and increased late morbidity and mortality. Timely reoperation may lead to a complete right ventricular recovery. An injectable PV allows pulmonary valve replacement, with or without cardiopulmonary bypass, under direct observation, thereby minimizing the impact of surgery on cardiac function. The aim of this study was to evaluate the feasibility and mid- to long-term clinical outcomes with this device. METHODS From April 2007 to October 2019, a total of 85 symptomatic patients with severe pulmonary regurgitation or pulmonary stenosis underwent pulmonary valve replacement with an injectable stented pulmonary prosthesis. Data were collected from the international proctoring registry. Mean patient age was 26.7 years. The underlying diagnosis was repaired tetralogy of Fallot in 69.4% patients; moderate or severe pulmonary regurgitation was present in 72.9%. All patients had echocardiographic scans before the operation and during the follow-up period. A total of 54.1% patients also had preoperative/postoperative cardiac magnetic resonance imaging (MRI) or catheterization; 25.9% had off-pump implants. In 53% patients, pulmonary valve replacement was associated with the repair of other cardiac defects. RESULTS Minor postoperative complications were observed in 10.8% patients. The overall mortality rate was 2.3%; mortality after valve replacement was linked to a severe cardiac insufficiency and it was not related to a prosthesis failure; 1 prosthesis was explanted from 1 patient because of endocarditis, and 6% of patients developed PV stenosis; minor complications occurred in 4.8%. The mean follow-up period was 4.8 years (2 months–12.7 years); 42% of the patients were followed for more than 5 years. Follow-up echocardiography and cardiac MRI showed a significant reduction in RV size and low gradients across the PV. CONCLUSIONS An injectable PV may be implanted without cardiopulmonary bypass and in a hybrid operating theatre with minimal surgical impact. The bioprosthesis, available up to large sizes, has a low profile, laminar flow and no risk of coronary artery compression. Incidence of endocarditis is rare. The lack of a suture ring permits the implant of a relatively larger prosthesis, thereby avoiding a right ventricular outflow tract obstruction. This device permits future percutaneous valve-in-valve procedures, if needed. Results concerning durability are encouraging, and mid- to long-term haemodynamic performance is excellent.


Circulation ◽  
2015 ◽  
Vol 132 (suppl_3) ◽  
Author(s):  
Abdeslam Bouzeman ◽  
Maxime De Guillebon ◽  
Guillaume Duthoit ◽  
Magalie Ladouceur ◽  
Raphael Martins ◽  
...  

Background: Tetralogy of Fallot (TOF) is the most frequent form of congenital heart disease managed by EP physicians for potential ICD. However, few studies have reported long-term outcomes of TOF patients with ICD. Methods: Between 2005 and 2014, all TOF patients with ICD in 17 French centers were enrolled in a specific evaluation aiming to determine characteristics at implantation as well as outcomes (overall mortality, appropriate ICD therapies, and device-related complications). Results: Overall 78 patients (45±13 years, 64% males) were enrolled. A majority of patients were implanted in the setting of secondary prevention (73%), whereas the remaining (27%) in primary prevention. Among the latest group, known risk factors for sudden cardiac death were: severe pulmonary regurgitation (30%,) prior palliative shunt (50%), syncope with unknown origin (25%), inducible ventricular tachycardia (45%), QRS duration ≥180ms (18%), non-sustained ventricular tachycardia (25%), and documented sustained supra ventricular tachycardia (45%).Overall, patients implanted in the setting of primary prevention presented with a mean of 3.1±1.4 risk factors. After a mean follow-up of 4.9±3.8 years, 35 patients (45%) experienced at least one appropriate therapy (25% in the primary prevention group compared to 53% in the secondary prevention group), giving annual-incidences of 6.9% (95%CI 0.14-13.7) and 21.3% (12.4-30.3) respectively (P=0,01). The mean time between ICD implantation and the first appropriate therapy was 2.2±3.2 years, without significant differences between primary and secondary prevention. Overall, ≥one ICD-related complication occurred in 30 patients (38%), including inappropriate shock (n=9), major pocket hematoma (n=1), lead dysfunction (n=12), infection (n=4), shoulder algodystrophia (n=2), device failure or dislodgement needing reintervention (n=2). Eventually, four patients were transplanted (5%), and six patients (8%) died during the course of follow-up. Conclusions: Considering relatively long-term follow-up, patients with TOF and ICDs experience high rates of appropriate ICD therapies, in both primary and secondary prevention. Major ICD-related complications remain, however, high.


1974 ◽  
Vol 85 (3) ◽  
pp. 429-433 ◽  
Author(s):  
Arthur Garson ◽  
Redford B. Williams ◽  
John Reckless

Sign in / Sign up

Export Citation Format

Share Document