Combined Use of Cu(II)-L-Histidine Complex and β-Cyclodextrin for the Enantioseparation of Three Amino Acids by CE and a Study of the Synergistic Effect

2020 ◽  
Vol 58 (10) ◽  
pp. 969-975
Author(s):  
Zifu Xu ◽  
Jin Guan ◽  
Huili Shao ◽  
Shitong Fan ◽  
Xiaoyu Li ◽  
...  

Abstract A new capillary electrophoresis method was applied to chiral separation of three amino acids, including D,L-tryptophan, D,L-tyrosine and D,L-phenylalanine. The chiral resolution was attained in an untreated fused-sillica capillary using a dual chiral selector, which was made up of Cu(II)-L-histidine complex and β-cyclodextrin (CD). The cardinal factors influencing its separation efficiency, such as chiral selectors, buffer pH and applied voltage, were optimized. Best results were acquired by using a buffer consisting of 10 mmol/L Cu(II), 13 mmol/L L-histidine, 8 mmol/L β-CD, 5 mmol/L phosphate adjusted to pH 5.0 and 15 kV applied voltage. All enantiomers were entirely resolved within 20 min with high resolutions of 3.6~6.1. The analysis method was verified through the determination of D,L-tryptophan in terms of linearity, precision and accuracy. And the robustness of this method was proved. The Limit of Detection and Limit of Quantification for both enantiomers were 2.5 and 5 μg/mL, respectively. The method was perfectly applied to the determination of the enantiomeric purity of L-tryptophan. Furthermore, the interaction between Cu(II)-L-histidine complex and β-CD was also studied using Ultraviolet-visible and 1H NMR spectroscopy to explain the synergistic effect involved. The results illustrated that Cu(II)-L-histidine complex and β-CD played a synergistic role in the enantiomeric separation of chiral drugs, with good prospects for application.

2013 ◽  
Vol 78 (6) ◽  
pp. 839-850 ◽  
Author(s):  
Igor Jajic ◽  
Sasa Krstovic ◽  
Dragan Glamocic ◽  
Sandra Jaksic ◽  
Biljana Abramovic

The subject of this study is the validation of a high-performance liquid chromatography method for the analysis of amino acids in feed. The contents of amino acids were determined in maize, soybean, soybean meal, as well as in their mixtures enriched with different amounts of methionine, threonine and lysine. The method involves the acid hydrolysis of the sample (6 h at 150?C), automated derivatisation of amino acids with the aid of o-phthaldialdehyde and 9-fluorenylmethyl chloroformate reagents, separation on the ZORBAX Eclipse-AAA column, and detection using a diode-array detector. The method is characterized by high specificity (the difference between the retention times of the feed samples and standard mixtures are below 1.7 %), wide linear range (from 10 to 1000 nmol cm-3, r2 = 0.9999), high accuracy (recovery 93.3-109.4 %), and the precision of the results (RSD below 4.14 % in case of repeatability and below 4.57 % in the case of intermediate precision). The limit of detection and the limit of quantification are in the range 0.004-1.258 ?g cm-3 and 0.011-5.272 ?g cm-3, respectively. The results demonstrate that the procedure can be used as a method for the determination of the composition of primary amino acids of feed proteins.


Author(s):  
Mohammad Hamzah Hamzah ◽  
Rawa M M Taqi ◽  
Muna M. Hasan ◽  
Raid J. M. Al-Timimi

A simple and accurate spectrophotometric method for the determination of Trifluoperazine HCl in pure and dosage forms was developed. The method is based on the reaction between Trifluoperazine HCl and p-chloroaniline in the presence of cerium ion as oxidizing agent which lead to the formation of violate color product that absorbed at a maximum wavelength 570nm while the blank solution was pink. Under the optimum conditions a linear relationship between the intensity and concentration of TRF in the range 4-50μg/ml was obtained . The molar absorptivity 3.74×103 L.mol-1.cm-1 , Limit of detection (2.21μg/ml), while limit of quantification was 7.39μg/ml. The proposed analytical method was compared with standard method using t-test and F-test , the obtained results shows there is no significant differences between proposed method and standard method. Based on that the proposed method can be used as an alternative method for the determination of TRF in pure and dosage forms.


2021 ◽  
Vol 7 (1) ◽  
Author(s):  
Indhu Priya Mabbu ◽  
G. Sumathi ◽  
N. Devanna

Abstract Background The aim of the present method is to develop and validate a specific, sensitive, precise, and accurate liquid chromatography-mass spectrometry (LC-MS) method for the estimation of the phenyl vinyl sulfone in the eletriptan hydrobromide. The effective separation of the phenyl vinyl sulfone was achieved by the Symmetry C18 (50 × 4.6 mm, 3.5 μm) column and a mobile phase composition of 0.1%v/v ammonia buffer to methanol (5:95 v/v), using 0.45 ml/min flow rate and 20 μl of injection volume, with methanol used as diluent. The phenyl vinyl sulfone was monitored on atomic pressure chemical ionization mode mass spectrometer with positive polarity mode. Results The retention time of phenyl vinyl sulfone was found at 2.13 min. The limit of detection (LOD) and limit of quantification (LOQ) were observed at 1.43 ppm and 4.77 ppm concentration respectively; the linear range was found in the concentration ranges from 4.77 to 27.00 ppm with regression coefficient of 0.9990 and accuracy in the range of 97.50–102.10%. The percentage relative standard deviation (% RSD) for six replicates said to be injections were less than 10%. Conclusion The proposed method was validated successfully as per ICH guidelines. Hence, this is employed for the determination of phenyl vinyl sulfone in the eletriptan hydrobromide.


Amino Acids ◽  
2021 ◽  
Author(s):  
Grażyna Gałęzowska ◽  
Joanna Ratajczyk ◽  
Lidia Wolska

AbstractThe quantitation and qualification of amino acids are most commonly used in clinical and epidemiological studies, and provide an excellent way of monitoring compounds in human fluids which have not been monitored previously, to prevent some diseases. Because of this, it is not surprising that scientific interest in evaluating these compounds has resurfaced in recent years and has precipitated the development of a multitude of new analytical techniques. This review considers recent developments in HPLC analytics on the basis of publications from the last few years. It helps to update and systematize knowledge in this area. Particular attention is paid to the progress of analytical methods, pointing out the advantages and drawbacks of the various techniques used for the preparation, separation and determination of amino acids. Depending on the type of sample, the preparation conditions for HPLC analysis change. For this reason, the review has focused on three types of samples, namely urine, blood and cerebrospinal fluid. Despite time-consuming sample preparation before HPLC analysis, an additional derivatization technique should be used, depending on the detection technique used. There are proposals for columns that are specially modified for amino acid separation without derivatization, but the limit of detection of the substance is less beneficial. In view of the fact that amino acid analyses have been performed for years and new solutions may generate increased costs, it may turn out that older proposals are much more advantageous.


Author(s):  
Kamran Ashraf ◽  
Syed Adnan Ali Shah ◽  
Mohd Mujeeb

<p><strong>Objective: </strong>A simple, sensitive, precise, and accurate stability indicating HPTLC (high-performance thin-layer chromatography) method for analysis of 10-gingerol in ginger has been developed and validated as perICH guidelines.</p><p><strong>Methods: </strong>The separation was achieved on TLC (thin layer chromatography) aluminum plates pre-coated with silica gel 60F<sub>254</sub> using n-hexane: ethyl acetate 55:45 (%, v/v) as a mobile phase. Densitometric analysis was performed at 569 nm.</p><p><strong>Results: </strong>This system was found to have a compact spot of 10-gingerol at <em>R</em><sub>F</sub> value of 0.57±0.03. For the proposed procedure, linearity (<em>r</em><sup>2</sup> = 0.998±0.02), limit of detection (18ng/spot), limit of quantification (42 ng/spot), recovery (ranging from 98.35%–100.68%), were found to be satisfactory.</p><p><strong>Conclusion: </strong>Statistical analysis reveals that the content of 10-gingerol in different geographical region varied significantly. The highest and lowest concentration of 10-gingerol in ginger was found to be present in a sample of Patna, Lucknow and Surat respectively which inferred that the variety of ginger found in Patna, Lucknow are much superior to other regions of India.</p>


2010 ◽  
Vol 7 (3) ◽  
pp. 807-812 ◽  
Author(s):  
Vanita Somasekhar ◽  
D. Gowri Sankar

A reverse phase HPLC method is described for the determination of esmolol hydrochloride in bulk and injections. Chromatography was carried on a C18column using a mixture of acetonitrile, 0.05 M sodium acetate buffer and glacial acetic acid (35:65:3 v/v/v) as the mobile phase at a flow rate of 1 mL/min with detection at 275 nm. The retention time of the drug was 4.76 min. The detector response was linear in the concentration of 1-50 μg/mL. The limit of detection and limit of quantification was 0.614 and 1.86 μg/mL respectively. The method was validated by determining its sensitivity, linearity, accuracy and precision. The proposed method is simple, economical, fast, accurate and precise and hence can be applied for routine quality control of esmolol hydrochloride in bulk and injections.


2012 ◽  
Vol 2012 ◽  
pp. 1-6
Author(s):  
S. N. Prashanth ◽  
Shankara S. Kalanur ◽  
Nagappa L. Teradal ◽  
J. Seetharamappa

The electrochemical behavior of isothipendyl hydrochloride (IPH) was investigated at bare and multiwalled-carbon-nanotube modified glassy carbon electrode (MWCNT-GCE). IPH (55 μM) showed two oxidation peaks in Britton-Robinson (BR) buffer of pH 7.0. The oxidation process of IPH was observed to be irreversible over the pH range of 2.5–9.0. The influence of pH, scan rate, and concentration of the drug on anodic peak was studied. A differential pulse voltammetric method with good precision and accuracy was developed for the determination of IPH in pure and biological fluids. The peak current was found to be linearly dependent on the concentration of IPH in the range of 1.25–55 μM. The values of limit of detection and limit of quantification were noticed to be 0.284 and 0.949 μM, respectively.


Molecules ◽  
2021 ◽  
Vol 26 (7) ◽  
pp. 1837
Author(s):  
Harischandra Naik Rathod ◽  
Bheemanna Mallappa ◽  
Pallavi Malenahalli Sidramappa ◽  
Chandra Sekhara Reddy Vennapusa ◽  
Pavankumar Kamin ◽  
...  

A quick, sensitive, and reproducible analytical method for the determination of 77 multiclass pesticides and their metabolites in Capsicum and tomato by gas and liquid chromatography tandem mass spectrometry was standardized and validated. The limit of detection of 0.19 to 10.91 and limit of quantification of 0.63 to 36.34 µg·kg−1 for Capsicum and 0.10 to 9.55 µg·kg−1 (LOD) and 0.35 to 33.43 µg·kg−1 (LOQ) for tomato. The method involves extraction of sample with acetonitrile, purification by dispersive solid phase extraction using primary secondary amine and graphitized carbon black. The recoveries of all pesticides were in the range of 75 to 110% with a relative standard deviation of less than 20%. Similarly, the method precision was evaluated interms of repeatability (RSDr) and reproducibility (RSDwR) by spiking of mixed pesticides standards at 100 µg·kg−1 recorded anRSD of less than 20%. The matrix effect was acceptable and no significant variation was observed in both the matrices except for few pesticides. The estimated measurement uncertainty found acceptable for all the pesticides. This method found suitable for analysis of vegetable samples drawn from market and farm gates.


INDIAN DRUGS ◽  
2021 ◽  
Vol 58 (06) ◽  
pp. 60-63
Author(s):  
Sadhana Rajput ◽  
◽  
Samir Patel ◽  

A new, specific, selective, simple, rapid and inexpensive spectrofluorophotometric method has been developed for the determination of tadalafil in spiked human plasma. The fluorescence spectrum of tadalafil in 0.1M methanolic sulphuric acid showed excitation wavelength at 315 nm and emission wave-length at 332 nm. The method for tadalafil was found to be linear over the concentration range of 10-50 ng/mL with a correlation coefficient of 0.9991. Limit of detection and limit of quantification were found to be 0.235 ng/mL and 0.701 ng/mL, respectively. The method was validated and found to be suitable for the estimation of tadalafil from human plasma. Satisfactory recovery of tadalafil from the human plasma suggests no interference of any debris present into human plasma. This method can be used to deter-mine plasma tadalafil concentration in drug monitoring or pharmacokinetic investigation.


2019 ◽  
Vol 31 (1) ◽  
pp. 1-9
Author(s):  
Deepak Kumar Sahu ◽  
Joyce Rai ◽  
Chhaya Bhatt ◽  
Manish K. Rai ◽  
Jyoti Goswami ◽  
...  

In modern age pesticide is used widely in agriculture. Lambda-cyhalothrin (LCT) is one of the most used pesticides which are used as a insecticide to kill pest, tricks, flies etc in agricultural field and it is also used for crop production. We have developed new method to detect LCT insecticide in agriculture field and reduce its uses. In this method we found the maximum absorbance at 460 nm for yellow colour dye. We also calculated limit of detection and limit of quantification 0.001 mg kg-1 and 0.056 mg kg-1 respectively. Molar absorptivity and Sandell’s sensitivity was also calculated and obtained 1.782 ×107 mol-1 cm-1 and 9.996 ×10-6 µg cm-2 respectively. The obtained yellow colour dye obeyed Beer’s law limit range of 0.5 µg ml -1 to 16 µg ml-1 in 25 ml. This method is less time consuming, selective, simple, sensitive and low cost. Present method is successfully applied in various soil, water and vegetable samples.


Sign in / Sign up

Export Citation Format

Share Document