Performance of Different Methods for Detection of Incipient Occlusal Caries Lesions: AnIn VitroStudy

2018 ◽  
Vol 36 (4) ◽  
pp. 191-197
Author(s):  
Sinem Akgul ◽  
Oya Bala ◽  
İhsan Yikilgan
2018 ◽  
Vol 23 (2) ◽  
pp. 847-853 ◽  
Author(s):  
J. E. A. Zenkner ◽  
A. Dalla Nora ◽  
L. S. Alves ◽  
J. Carvalho ◽  
M. B. Wagner ◽  
...  

2017 ◽  
Vol 6 (1) ◽  
pp. 48
Author(s):  
MariaAparecida Alves de Cerqueira Luz ◽  
AnaDaniela Silva da Silveira ◽  
Nath�lia Carolina Fernandes Fagundes ◽  
CesarAngelo Lascala ◽  
Ant�nio Jos� da Silva Nogueira ◽  
...  

Author(s):  
Fausto Medeiros Mendes ◽  
Victor Moreira Leamari ◽  
Márcia Turolla Wanderley ◽  
Mariana Minatel Braga ◽  
Juliana Mattos-Silveira ◽  
...  

Objective: This study aimed to investigate the association of two fluorescent dyes and Laser Fluorescence (LF) device in detecting smooth and occlusal natural caries in primary teeth in vitro.Methods: Measurements were performed with the LF and with LF associated with tetrakis (N-methylpyridyl)porphyrin (LF TMPyP) and protoporphyrin IX (LF PPIX) in 72 smooth (63 primary molars) and 134 occlusal sites (81 primary molars). For validation, surfaces were sectioned and sections obtained were evaluated under stereomicroscope. Smooth surfaces were also evaluated using polarized light microscopy and Knoop microhardness. For both smooth and occlusal surfaces, ROC analyses were performed, and sensitivities, specificities and accuracies were assessed. In smooth surfaces, Pearson’s correlation coefficients between LF values and lesions hardness or lesions depth were calculated.Results: LF TMPyP presented higher correlation with hardness and lesion depth than other methods in smooth surfaces. No differences were observed in other parameters among the methods, in both smooth and occlusal surfaces.Relevance: The LF TMPyP might improve performance in quantifying smooth-surface caries lesions in primary teeth. However, the sensitivity is improved at D2 (caries extending into inner half of the enamel but not to amelodentinal junction) threshold when using PPIX in smooth caries lesions. The association of LF with fluorescent dyes does not improve the performance on occlusal caries.


2018 ◽  
Vol 66 (2) ◽  
pp. 141-146
Author(s):  
Amanda de Albuquerque VASCONCELOS ◽  
Juliana Tietbohl de Almeida REIS ◽  
Bianca Fiorentin MOURA ◽  
Daniela Cavalcante GIRÃO ◽  
José Carlos Pettorossi IMPARATO ◽  
...  

ABSTRACT Objective: To evaluate the sealing of cavities of dentinal occlusal caries lesions, reproduced in vitro, with flow resin compared to cavity restorations presenting healthy dentin using microhybrid composite resin. Methods: The sample consisted of 27 healthy deciduous molars where cavities of approximately 2 mm in the fossa region were performed and occlusal cleft of each tooth were sealed, impermeabilization was performed and the sample was randomly divided into 2 groups: group I underwent cariogenic challenge and occlusal sealing with resin flow. The teeth of group II were restored with microhybrid composite resin. The teeth were immersed in 5% methylene blue for 8 hours at 37° C and washed until all the dye was removed from the surface. The teeth were sectioned in the mesio-distal direction. The penetration of the dye was evaluated: 0- no penetration; 1- dye penetration up to 1/3 of the restoration; 2- dye penetration up to 2/3 of the restoration depth; 3 - penetration of dye into the pulp wall. The results were analyzed by the Biostat 4.0 program. Descriptive analysis and the mode among the examiners submitted to the Mann-Whitney test. Results: There was no significant difference in microleakage between restoration performed in healthy dentin with microhybrid composite resin or maintenance of infected dentin in primary teeth sealed with resin flow (p = 0.6035). Conclusion: It was concluded that the marginal infiltration of primary molars sealed with microhybrid composite resin and resin flow was not influenced by the removal -or not -of the carious tissue or the material used.


2018 ◽  
Vol 69 ◽  
pp. 83-87 ◽  
Author(s):  
Sonia K. Makhija ◽  
Michael E. Robinson ◽  
James D. Bader ◽  
Daniel A. Shugars ◽  
Mark S. Litaker ◽  
...  

2006 ◽  
Vol 30 (4) ◽  
pp. 306-309 ◽  
Author(s):  
Renata Maciel e Rocha Cabral ◽  
Fausto Medeiros Mendes ◽  
José Nicolau ◽  
Denise Maria Zezell

The goal of this study was to evaluate the influence of a PVC Seal Wrap as barrier protection and the influence of autoclaving on the in vitro performance of a laser fluorescence device in detecting occlusal caries lesions in primary teeth. The clinical significance of the experiment is to create a protocol to avoid the possibility of underestimating caries in clinical setting.


2019 ◽  
Vol 20 (3) ◽  
pp. 279-284
Author(s):  
Sérgio AP Freitas ◽  
Francine K Panzarella ◽  
Roseli H Karia ◽  
Mariana RM Cavaletti ◽  
José Luiz C Junqueira ◽  
...  

2014 ◽  
Vol 145 (11) ◽  
pp. 1112-1118 ◽  
Author(s):  
Sonia K. Makhija ◽  
Gregg H. Gilbert ◽  
Ellen Funkhouser ◽  
James D. Bader ◽  
Valeria V. Gordan ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document