The Impact of Operating Room Noise Upon Communication During Percutaneous Nephrostolithotomy

2016 ◽  
Vol 30 (10) ◽  
pp. 1062-1066 ◽  
Author(s):  
Salim Cheriyan ◽  
Hayley Mowery ◽  
David Ruckle ◽  
Mohamed Keheila ◽  
Kristene Myklak ◽  
...  
2021 ◽  
pp. 152660282199672
Author(s):  
Giovanni Tinelli ◽  
Marie Bonnet ◽  
Adrien Hertault ◽  
Simona Sica ◽  
Gian Luca Di Tanna ◽  
...  

Purpose: Evaluate the impact of hybrid operating room (HOR) guidance on the long-term clinical outcomes following fenestrated and branched endovascular repair (F-BEVAR) for complex aortic aneurysms. Materials and Methods: Prospectively collected registry data were retrospectively analyzed to compare the procedural, short- and long-term outcomes of consecutive F-BEVAR performed from January 2010 to December 2014 under standard mobile C-arm versus hybrid room guidance in a high-volume aortic center. Results: A total of 262 consecutive patients, including 133 patients treated with a mobile C-arm equipped operating room and 129 with a HOR guidance, were enrolled in this study. Patient radiation exposure and contrast media volume were significantly reduced in the HOR group. Short-term clinical outcomes were improved despite higher case complexity in the HOR group, with no statistical significance. At a median follow-up of 63.3 months (Q1 33.4, Q3 75.9) in the C-arm group, and 44.9 months (Q1 25.1, Q3 53.5, p=0.53) in the HOR group, there was no statistically significant difference in terms of target vessel occlusion and limb occlusion. When the endograft involved 3 or more fenestrations and/or branches (complex F-BEVAR), graft instability (36% vs 25%, p=0.035), reintervention on target vessels (20% vs 11%, p=0.019) and total reintervention rates (24% vs 15%, p=0.032) were significantly reduced in the HOR group. The multivariable Cox regression analysis did not show statistically significant differences for long-term death and aortic-related death between the 2 groups. Conclusion: Our study suggests that better long-term clinical outcomes could be observed when performing complex F-BEVAR in the latest generation HOR.


Surgery ◽  
2005 ◽  
Vol 137 (5) ◽  
pp. 518-526 ◽  
Author(s):  
James E. Stahl ◽  
Marie T. Egan ◽  
Julian M. Goldman ◽  
Dawn Tenney ◽  
Richard A. Wiklund ◽  
...  

2007 ◽  
Vol 15 (4) ◽  
pp. 307-309 ◽  
Author(s):  
Andrew J Drain ◽  
Jonathon I Ferguson ◽  
Sharon Wilkinson ◽  
Samer AM Nashef

There may be conflict between the requirements of surgical training and those of the clinical service if training has an impact on clinical outcomes. One area of potential impact is perioperative blood loss. We compared total and 12-hour blood loss after 2,079 consecutive cardiac operations performed over 2 years by trainees and consultants. One- and two-way analyses of variance with EuroSCORE and surgeon status as factors were carried out to evaluate the impact of surgeon status on blood loss. There was no difference in blood loss between consultants and trainees. We also compared the rates between consultants and trainees of patients returning to the operating room due to bleeding. This showed a significant difference, with trainees having a higher rate of investigation for bleeding. Cardiac surgical training can be achieved without an adverse effect on blood loss, but it may be associated with a higher rate of re-intervention for bleeding.


2018 ◽  
Vol 25 (1) ◽  
pp. 67 ◽  
Author(s):  
N. Mundi ◽  
J. Theurer ◽  
A. Warner ◽  
J. Yoo ◽  
K. Fung ◽  
...  

Background Operating room slowdowns occur at specific intervals in the year as a cost-saving measure. We aim to investigate the impact of these slowdowns on the care of oral cavity cancer patients at a Canadian tertiary care centre.Methods A total of 585 oral cavity cancer patients seen between 1999 and 2015 at the London Health Science Centre (lhsc) Head and Neck Multidisciplinary Clinic were included in this study. Operating room hours and patient load from 2006 to 2014 were calculated. Our primary endpoint was the wait time from consultation to definitive surgery. Exposure variables were defined according to wait time intervals occurring during time periods with reduced operating room hours.Results Overall case volume rose significantly from 2006 to 2014 (p < 0.001), while operating room hours remained stable (p = 0.555). Patient wait times for surgery increased from 16.3 days prior to 2003 to 25.5 days in 2015 (p = 0.008). Significant variability in operating room hours was observed by month, with lowest reported for July and August (p = 0.002). The greater the exposure to these months, the more likely patients were to wait longer than 28 days for surgery (odds ratio per day [or]: 1.07, 95% confidence interval [ci]: 1.05 to 1.10, p < 0.001). Individuals seen in consultation preceding a month with below average operating room hours had a higher risk of disease recurrence and/or death (hazard ratio [hr]: 1.59, 95% ci: 1.10 to 2.30, p = 0.014).Conclusions Scheduled reductions in available operating room hours contribute to prolonged wait times and higher disease recurrence. Further work is needed to identify strategies maximizing efficient use of health care resources without negatively affecting patient outcomes.


2019 ◽  
Vol 19 (1) ◽  
Author(s):  
R. Ryan Field ◽  
Tuan Mai ◽  
Samouel Hanna ◽  
Brian Harrington ◽  
Michael-David Calderon ◽  
...  

Abstract Background Goal Directed Fluid Therapy (GDFT) represents an objective fluid replacement algorithm. The effect of provider variability remains a confounder. Overhydration worsens perioperative morbidity and mortality; therefore, the impact of the calculated NPO deficit prior to the operating room may reach harm. Methods A retrospective single-institution study analyzed patients at UC Irvine Medical Center main operating rooms from September 1, 2013 through September 1, 2015 receiving GDFT. The primary study question asked if GDFT suggested different fluid delivery after different NPO periods, while reducing inter-provider variability. We created two patient groups distinguished by 0715 surgical start time or start time after 1200. We analyzed fluid administration totals with either a 1:1 crystalloid to colloid ratio or a 3:1 ratio. We performed direct group-wise testing on total administered volume expressed as total ml, total ml/hr., and total ml/kg/hr. between the first case start (AM) and afternoon case (PM) groups. A linear regression model included all baseline covariates that differed between groups as well as plausible confounding factors for differing fluid needs. Finally, we combined all patients from both groups, and created NPO time to total administered fluid scatterplots to assess the effect of patient-reported NPO time on fluid administration. Results Whether reported by total administered volume or net fluid volume, and whether we expressed the sum as ml, ml/hr., or ml/kg/hr., the AM group received more fluid on average than the PM group in all cases. In the general linear models, for all significant independent variables evaluated, AM vs PM case start did not reach significance in both cases at p = 0.64 and p = 0.19, respectively. In scatterplots of NPO time to fluid volumes, absolute adjusted and unadjusted R2 values are < 0.01 for each plot, indicating virtually non-existent correlations between uncorrected NPO time and fluid volumes measured. Conclusions This study showed NPO periods do not influence a patient’s volume status just prior to presentation to the operating room for surgical intervention. We hope this data will influence the practice of providers routinely replacing calculated NPO period volume deficit; particularly with those presenting with later surgical case start times.


2019 ◽  
Vol 2019 ◽  
pp. 1-5 ◽  
Author(s):  
Cara Marie Rogers ◽  
Hannah Palmerton ◽  
Brian Saway ◽  
Devin Tomlinson ◽  
Gary Simonds

Background. The amalgam of noises inherent to the modern-day operating room has the potential of diluting surgeon concentration, which could affect surgeon performance and mood and have implications on quality of care and surgeon resilience. Objective. Evaluate the impact of operating room environmental noises on surgeon performance including fine motor dexterity, cognition, and mood. Methods. 37 subjects were tested under three different environmental noise conditions including silence, a prerecorded soundtrack of a loud bustling operating room, and with background music of their choosing. We used the Motor Performance Series to test motor dexterity, neuropsychological tests to evaluate cognitive thinking, and Profile of Mood States to test mental well-being. Results. Our results showed that typical operating room noise had no impact on motor dexterity but music improved the speed and precision of movements and information processing skills. Neurocognitive testing showed a significant decrement from operating room noise on verbal learning and delayed memory, whereas music improved complex attention and mental flexibility. The Profile of Mood States found that music resulted in a significant decrease in feelings of anger, confusion, fatigue, and tension along with decreased total mood disturbance, which is a measure of psychological distress. Loud operating room noise had a negative impact on feelings of vigor but no increase in total mood disturbance. Conclusion. Our results suggest that loud and unnecessary environmental noises can be distracting to a surgeon, so every effort should be taken to minimize these. Music of the surgeons’ choosing does not negatively affect fine motor dexterity or cognition and has an overall positive impact on mood and can therefore be safely practiced if desired.


2003 ◽  
Vol 24 (1) ◽  
pp. 13-16 ◽  
Author(s):  
Giorgio Zanetti ◽  
Hugh L. Flanagan ◽  
Lawrence H. Cohn ◽  
Richard Giardina ◽  
Richard Platt

AbstractObjective:To assess the impact of an automated intraoperative alert to redose prophylactic antibiotics in prolonged cardiac operations.Design:Randomized, controlled, evaluator-blinded trial.Setting:University-affiliated hospital.Patients:Patients undergoing cardiac surgery that lasted more than 4 hours after the preoperative administration of cefazolin, unless they were receiving therapeutic antibiotics at the time of surgery.Intervention:Randomization to an audible and visual reminder on the operating room computer console at 225 minutes after the administration of preoperative antibiotics (reminder group, n = 137) or control (n = 136). After another 30 minutes, the circulating nurse was required to indicate whether a follow-up dose of antibiotics had been administered.Results:Intraoperative redosing was significantly more frequent in the reminder group (93 of 137; 68%) than in the control group (55 of 136; 40%) (adjusted odds ratio, 3.31; 95% confidence interval, 1.97 to 5.56; P < .0001). The impact of the reminder was even greater when compared with the 6 months preceding the study period (129 of 480; 27%; P < .001), suggesting some spillover effect on the control group. Redosing was formally declined for 19 of the 44 patients in the reminder group without redosing. The rate of surgical-site infection in the reminder group (5 of 137; 4%) was similar to that in the control group (8 of 136; 6%; P = .42), but significantly lower than that in the pre-study period (48 of 480; 10%; P = .02).Conclusion:The use of an automatic reminder system in the operating room improved compliance with guidelines on perioperative antibiotic prophylaxis.


2003 ◽  
pp. 1119-1126 ◽  
Author(s):  
Franklin Dexter ◽  
Amr E. Abouleish ◽  
Richard H. Epstein ◽  
Charles W. Whitten ◽  
David A. Lubarsky

Sign in / Sign up

Export Citation Format

Share Document