The dielectric behaviour of clay soils and its application to time domain reflectometry

Soil Research ◽  
1996 ◽  
Vol 34 (6) ◽  
pp. 825 ◽  
Author(s):  
BJ Bridge ◽  
J Sabburg ◽  
KO Habash ◽  
JAR Ball ◽  
NH Hancock

The dielectric behaviour of 3 soils, a sandy loam (Red Chromosol), a highly structured non-swelling clay (Red Ferrosol), and a self-mulching swelling clay (Black Vertosol), was investigated using a waveguide and network analyser technique in the frequency range 3.0 GHz to 4.5 GHz. Curves relating the real part of the relative permittivity to water content are presented and compared with the general Topp curve. The Chromosol generally followed the Topp curve, but the Ferrosol and Vertosol both had curves below the Topp curve. The Ferrosol showed a maximum horizontal offset of 0.05 m3/m3 from the Topp curve in the mid soil-water content range of 0.2–0.3 m3/m3 offset from the Topp curve of 0.10 m3/m3, with a maximum of 0.12 m3/m3 occurring at a soil water content of 0.4 m3/m3. Similar dielectric curves were obtained for the Chromosol and Vertosol using time domain reflectometry (TDR). With this method, the Chromosol showed very close agreement with the Topp curve, but the Vertosol again gave a curve below the Topp curve, similar to the one obtained using the waveguide and network analyser, but with a smaller maximum horizontal offset of 0.08 m3/m3. The difference between the waveguide and TDR Vertosol curves was mainly attributed to low bulk densities in the waveguide where packing was difficult. Some was also attributed to the wider spectrum of frequencies used by TDR. Use of the Topp curve for TDR measurements in the Vertosol would underestimate its water content by at least 0.06 m3/m3. These results are in good agreement with others obtained from similar soils. Deviations from the Topp curve are attributed to bound water associated with the clay particles and this depends on clay mineralogy and clay content. The presented calibration curves improve the accuracy of TDR measurements in these types of clay soils. A field comparison between water contents measured by TDR and gravimetric sampling in a similar Black Vertosol is presented. This calibration showed that soil water contents can be severely overestimated by using TDR with long probes and cables. This unexpected and opposite result is discussed in terms of attenuated high frequencies in the 15-m-long connecting cable used, errors in depth of probe placement, and changes in bulk density and DC conductivity.

1987 ◽  
Vol 24 (1) ◽  
pp. 160-163 ◽  
Author(s):  
T. H. W. Baker ◽  
L. E. Goodrich

A two-pronged metal probe measures the thermal conductivity and apparent dielectric constant of soils in the laboratory and in the field. One prong acts as a transient line heat source probe in measuring thermal conductivity. The apparent dielectric constant of the soil is determined by the time-domain reflectometry (TDR) technique, using both prongs as a parallel transmission line. Volumetric water content is determined from the apparent dielectric constant, making use of an empirical relation valid for most soils. For volumetric water contents above about 8%, the apparent dielectric constant shows a strong dependence on water content and relatively small changes can be measured; sensitivity increases with water content. For volumetric water contents less than 8%, a soil-dependent empirical relation between water content and thermal conductivity has been developed that is most sensitive at lower water contents. The combined probe provides a means of monitoring the water content of soils over a wide range of values, in the field and in the laboratory. Key words: soil water content, time-domain reflectometry, thermal conductivity.


2000 ◽  
Vol 80 (1) ◽  
pp. 53-61 ◽  
Author(s):  
L. M. Dwyer ◽  
B. L. Ma ◽  
R. de Jong ◽  
M. Tollenaar

Seedbed temperature and moisture conditions affect crop emergence rate and stand establishment. A 4 × 4 factorial experiment arranged in a split plot design with four replications was conducted for 3 yr at four sites to measure corn emergence rate and stand establishment while monitoring seedbed temperature and soil water content in situ. Four planting dates, beginning as early as the soil could be worked and every 10 d thereafter, were the main plots and four corn (Zea mays L.) hybrids the subplots. Volumetric soil water content in the top 0.10 m was measured a minimum of two times per week using time domain reflectometry (TDR) and estimated daily using a budget model. Measured and estimated soil water contents were similar (R2 = 0.73) and daily estimated values were used in the analysis. Stand establishment for most planting date-site-years ranged from 80 to 99%. Less than 15% of planting date-site-years had stands below 80%, and they were characterized by soil temperatures at or below 12.5°C combined with high soil water contents (>90% available water). Rate of emergence was not associated with stand establishment (P > 0.10) and could not be predicted from soil temperatures below 12.5°C. Results suggest that reduction in stand establishment under conditions of low (12.5°C) soil temperature and high (>field capacity) soil water content may be a factor in corn yield reductions associated with reduced or no tillage. Key words: Time domain reflectometry, soil water content, soil temperature, maize


Soil Science ◽  
2010 ◽  
Vol 175 (10) ◽  
pp. 469-473 ◽  
Author(s):  
Zhaoqiang Ju ◽  
Xiaona Liu ◽  
Tusheng Ren ◽  
Chunsheng Hu

1998 ◽  
Vol 2 (1) ◽  
pp. 111-120 ◽  
Author(s):  
D. A. Robinson ◽  
C. M. K. Gardner ◽  
J. Evans ◽  
J. D. Cooper ◽  
M. G. Hodnett ◽  
...  

Abstract. Capacitance probes are a fast, safe and relatively inexpensive means of measuring the relative permittivity of soils, which can then be used to estimate soil water content. Initial experiments with capacitance probes used empirical calibrations between the frequency response of the instrument and soil water content. This has the disadvantage that the calibrations are instrument-dependent. A twofold calibration strategy is described in this paper; the instrument frequency is turned into relative permittivity (dielectric constant) which can then be calibrated against soil water content. This approach offers the advantages of making the second calibration, from soil permittivity to soil water content. instrument-independent and allows comparison with other dielectric methods, such as time domain reflectometry. A physically based model, used to calibrate capacitance probes in terms of relative permittivity (εr) is presented. The model, which was developed from circuit analysis, predicts, successfully, the frequency response of the instrument in liquids with different relative permittivities, using only measurements in air and water. lt was used successfully to calibrate 10 prototype surface capacitance insertion probes (SCIPS) and a depth capacitance probe. The findings demonstrate that the geometric properties of the instrument electrodes were an important parameter in the model, the value of which could be fixed through measurement. The relationship between apparent soil permittivity and volumetric water content has been the subject of much research in the last 30 years. Two lines of investigation have developed, time domain reflectometry (TDR) and capacitance. Both methods claim to measure relative permittivity and should therefore be comparable. This paper demonstrates that the IH capacitance probe overestimates relative permittivity as the ionic conductivity of the medium increases. Electrically conducting ionic solutions were used to test the magnitude of this effect on the determination of relative permittivity. The response was modelled so that the relative permittivity, independent of ionic conductivity, could be determined in solutions with an electrical conductivity of up to 0.25 S m-1. It was found that a solution EC of less than 0.05 S m-1 had little impact on the permittivity measurement.