scholarly journals Potentiometric determination of total nitrogen in soils by flow injection analysis with a gas-diffusion unit

Soil Research ◽  
1996 ◽  
Vol 34 (4) ◽  
pp. 503 ◽  
Author(s):  
AMR Ferreira ◽  
J Lima ◽  
A Rangel

A flow injection analysis (FIA) system incorporating a gas-diffusion unit and a potentiometric detector was developed for the determination of total nitrogen in soil digests. The solutions obtained from the Kjeldahl digestion of the soil samples were injected in the FIA system where ammonium was converted into ammonia. This gas diffused through a gas-permeable membrane to a buffer acceptor stream, allowing the separation of the gas from the rest of the sample. Once in contact with the buffer solution, ammonia was reconverted into ammonium and finally led to a tubular ammonium ion-selective electrode constructed for this purpose. The potentiometric detector is a PVC tubular selective electrode without inner reference solution, and with the sensor system composed of monactin in Tris (2-ethylhexyl) phosphate. Good agreement was obtained between the results provided with the developed FIA system and those from the classical Kjeldahl distillation/titration step, with relative deviations between the 2 methods always < 5%. A sampling rate of 80 determinations/h was achieved with good reproducibility for consecutive injections of soil digests (coefficients of variation < 3%).

2016 ◽  
Vol 20 ◽  
pp. 73-75 ◽  
Author(s):  
Sumonmarn Chaneam ◽  
Waritta Taweetong ◽  
Kampanart Kaewyai ◽  
Pheeraphon Thienwong ◽  
Aekgaraj Takaew ◽  
...  

1993 ◽  
Vol 65 (23) ◽  
pp. 3489-3492 ◽  
Author(s):  
Xincheng. Hu ◽  
Norimichi. Takenaka ◽  
Shiro. Takasuna ◽  
Masaru. Kitano ◽  
Hiroshi. Bandow ◽  
...  

2011 ◽  
Vol 23 (11) ◽  
pp. 2594-2600 ◽  
Author(s):  
Henrique L. Braz ◽  
Débora T. Ito ◽  
José A. Fracassi da Silva ◽  
Claudimir L. do Lago ◽  
Jairo J. Pedrotti

2018 ◽  
Vol 34 (2) ◽  
pp. 67
Author(s):  
Orlando Fatibello-Filho ◽  
Heberth Juliano Vieira

A spectrophotometric flow injection method for the determination of Zn(II) in ophthalmic formulations was developed. In this work, Zn(II) ion was complexed with Alizarin red S in borate buffer solution (pH 9.0) and the chromophore produced was monitored at 520 nm. The analytical curve was linear in the Zn(II) concentration range from 6.05 x 10-6 to 1.50 x 10-4 mol L-1 with a detection limit of 3.60 x 10-6 mol L-1. Recoveries ranged from 96.3 to 105 % and a relative standard deviation of 1.2 % (n = 10) for 5.5x10-5 mol L-1 Zn(II) reference solution were obtained. The sampling rate was 60 h-1 and the results obtained of Zn(II) in ophthalmic products using this procedure are in close agreement with those obtained using a comparative spectrophotometric procedure at 95 % confidence level.