Filtration characteristics of Clarke-Bumpus samplers

1965 ◽  
Vol 16 (3) ◽  
pp. 281 ◽  
Author(s):  
DJ Tranter ◽  
AC Heron

The Australian and American models of the sampler were tested at water velocities up to 3.5 kt. A calibration tank designed to simulate normal flow conditions through the flowmeter was used to calibrate flowmeter rate against flow rate measured at a 90� V-notch exit. This calibration was used to determine the discharge through samplers towed for a measured distance in a water channel. Thus the filtration characteristics of the samplers were examined. The filtration coefficient for the American sampler without a net averaged 88 %, compared with 92% for the Australian sampler. Australian nets reduced the filtration coefficient of the Australian sampler by 2-15 %. The American net had little effect on the filtration coefficient of the American sampler. The filtration coefficient varied with mesh aperture and clogging but was largely independent of towing velocity. Other experiments suggested that net length was less important, and the flow of water around the net more important, than previously thought. Above approximately 1 kt, the calibration value was nearly independent of velocity and hardly altered with net attachment no matter how fine the mesh.

2021 ◽  
Vol 2 (1) ◽  
pp. 61-77
Author(s):  
Hamid Reza Jafari ◽  
Ali Davoodi ◽  
Saman Hosseinpour

In this work, the corrosion behavior and surface reactivity of as-cast and heat-treated nickel aluminum bronze casting alloy (UNS C95800) in 3.5 wt% NaCl solution is investigated under stagnant and flow conditions. Increasing flow rate conditions are simulated using a rotating disk electrode from 0 to 9000 revolutions per minute (rpm). Optical micrographs confirm the decrease in the phase fraction of corrosion-sensitive β phase in the microstructure of C95800 after annealing, which, in turn, enhances the corrosion resistance of the alloy. Electrochemical studies including open circuit potentiometry, potentiodynamic polarization, and electrochemical impedance spectroscopy are performed to assess the effect of flow rate and heat treatment on the corrosion of samples at 25 and 40 °C in 3.5 wt% NaCl solution. For both as-cast and heat-treated samples, increasing the flow rate (i.e., electrode rotating rate) linearly reduces the corrosion resistance, indicating that the metal dissolution rate is significantly affected by hydrodynamic flow. Increasing the solution temperature negatively impacts the corrosion behavior of the as-cast and heat-treated samples at all flow conditions.


2021 ◽  
Vol 9 (1) ◽  
Author(s):  
Tobias Blanke ◽  
Markus Hagenkamp ◽  
Bernd Döring ◽  
Joachim Göttsche ◽  
Vitali Reger ◽  
...  

AbstractPrevious studies optimized the dimensions of coaxial heat exchangers using constant mass flow rates as a boundary condition. They show a thermal optimal circular ring width of nearly zero. Hydraulically optimal is an inner to outer pipe radius ratio of 0.65 for turbulent and 0.68 for laminar flow types. In contrast, in this study, flow conditions in the circular ring are kept constant (a set of fixed Reynolds numbers) during optimization. This approach ensures fixed flow conditions and prevents inappropriately high or low mass flow rates. The optimization is carried out for three objectives: Maximum energy gain, minimum hydraulic effort and eventually optimum net-exergy balance. The optimization changes the inner pipe radius and mass flow rate but not the Reynolds number of the circular ring. The thermal calculations base on Hellström’s borehole resistance and the hydraulic optimization on individually calculated linear loss of head coefficients. Increasing the inner pipe radius results in decreased hydraulic losses in the inner pipe but increased losses in the circular ring. The net-exergy difference is a key performance indicator and combines thermal and hydraulic calculations. It is the difference between thermal exergy flux and hydraulic effort. The Reynolds number in the circular ring is instead of the mass flow rate constant during all optimizations. The result from a thermal perspective is an optimal width of the circular ring of nearly zero. The hydraulically optimal inner pipe radius is 54% of the outer pipe radius for laminar flow and 60% for turbulent flow scenarios. Net-exergetic optimization shows a predominant influence of hydraulic losses, especially for small temperature gains. The exact result depends on the earth’s thermal properties and the flow type. Conclusively, coaxial geothermal probes’ design should focus on the hydraulic optimum and take the thermal optimum as a secondary criterion due to the dominating hydraulics.


2019 ◽  
Vol 7 (1) ◽  
Author(s):  
Jia Wang ◽  
Fabian Nitschke ◽  
Maziar Gholami Korzani ◽  
Thomas Kohl

Abstract Temperature logs have important applications in the geothermal industry such as the estimation of the static formation temperature (SFT) and the characterization of fluid loss from a borehole. However, the temperature distribution of the wellbore relies on various factors such as wellbore flow conditions, fluid losses, well layout, heat transfer mechanics within the fluid as well as between the wellbore and the surrounding rock formation, etc. In this context, the numerical approach presented in this paper is applied to investigate the influencing parameters/uncertainties in the interpretation of borehole logging data. To this end, synthetic temperature logs representing different well operation conditions were numerically generated using our newly developed wellbore simulator. Our models account for several complex operation scenarios resulting from the requirements of high-enthalpy wells where different flow conditions, such as mud injection with- and without fluid loss and shut-in, occur in the drill string and the annulus. The simulation results reveal that free convective heat transfer plays an important role in the earlier evolution of the shut-in-time temperature; high accuracy SFT estimation is only possible when long-term shut-in measurements are used. Two other simulation scenarios for a well under injection conditions show that applying simple temperature correction methods on the non-shut-in temperature data could lead to large errors for SFT estimation even at very low injection flow rates. Furthermore, the magnitude of the temperature gradient increase depends on the flow rate, the percentage of fluid loss and the lateral heat transfer between the fluid and the rock formation. As indicated by this study, under low fluid losses (< 30%) or relatively higher flow rates (> 20 L/s), the impact of flow rate and the lateral heat transfer on the temperature gradient increase can be ignored. These results provide insights on the key factors influencing the well temperature distribution, which are important for the choice of the drilling data to estimate SFT and the design of the inverse modeling scheme in future studies to determine an accurate SFT profile for the high-enthalpy geothermal environment.


2017 ◽  
Vol 13 (2) ◽  
Author(s):  
B Vivekanandan ◽  
K Jeyannathann ◽  
A. Seshagiri Rao

Abstract The quality of a treated effluent changes when there is a sudden variation in the influent flow to the wastewater treatment plant during dry, rain, and storm weather conditions. In this study, various influent flow conditions in an activated sludge process are considered that affect the sensitivity of effluent variables such as chemical oxygen demand (COD), biological oxygen demand (BOD), nitrate nitrogen (SNO), ammonical nitrogen (SNH), and total nitrogen (TN) with respect to varying internal recycle flow rate (Qa), sludge recycle flow rate (Qr), sludge wastage flow rate (Qw) and oxygen transfer rate co-efficient of aerobic tanks (KLa(3,4,5)). The analysis has been carried out based on benchmark simulation model no.1 (BSM 1) plant layout which comprises of two models namely activated sludge model no.1 (ASM 1) and simple one dimensional (Simple 1-D) Takacs model. Based on the present analysis, it is observed that the changes in influent flow rate have larger impact on the effluent variables. This variation can be subdued by introducing additional tanks to smoothen the perturbations or using internal recycle rate from the fifth tank in order to maintain the flow around the optimal influent flow rate. The sludge wastage rate has a greater impact on all effluent variables except nitrogenous variables during maximum flow conditions.


Author(s):  
Kevin Reid ◽  
John Denton ◽  
Graham Pullan ◽  
Eric Curtis ◽  
John Longley

An investigation into the effect of stator-rotor hub gap sealing flow on turbine performance is presented. Efficiency measurements and rotor exit area traverse data from a low speed research turbine are reported. Tests carried out over a range of sealing flow conditions show that the turbine efficiency decreases with increasing sealant flow rate but that this penalty is reduced by swirling the sealant flow. Results from time-accurate and steady-state simulations using a three-dimensional multi-block RANS solver are presented with particular emphasis paid to the mechanisms of loss production. The contributions toward entropy generation of the mixing of the sealant fluid with the mainstream flow and of the perturbed rotor secondary flows are assessed. The importance of unsteady stator wake/sealant flow interactions is also highlighted.


2013 ◽  
Vol 10 (2) ◽  
pp. 2767-2790 ◽  
Author(s):  
S. Nagao ◽  
M. Kanamori ◽  
S. Ochiai ◽  
S. Tomihara ◽  
K. Fukushi ◽  
...  

Abstract. Effects of a heavy rain event on radiocesium export were studied at stations on the Natsui River and the Same River in Fukushima Prefecture, Japan after Typhoon Roke during 21–22 September 2011, six months after the Fukushima Daiichi Nuclear Power Plant accident. Radioactivity of 134Cs and 137Cs in river waters was 0.011–0.098 Bq L−1 at normal flow conditions during July–September in 2011, but it increased to 0.85 Bq L−1 in high flow conditions by heavy rains occurring with the typhoon. The particulate fractions of 134Cs and 137Cs were 21–56% in the normal flow condition, but were close to 100% after the typhoon. These results indicate that the pulse input of radiocesium associated with suspended particles from land to coastal ocean occurred by the heavy rain event. Export flux of 134Cs and 137Cs by the heavy rain accounts for 30–50% of annual radiocesium flux in 2011. Results show that rain events are one factor controlling the transport and dispersion of radiocesium in river watersheds and coastal marine environments.


2016 ◽  
Author(s):  
C. Orru ◽  
A. Blom ◽  
W.S.J. Uijttewaal

Abstract. Armor breakup and reformation was studied in a laboratory experiment using a trimodal mixture composed of sand and gravel. The armor was formed in the initial stage of the experiment under conditions without sediment supply. Higher flow conditions led to the breakup of the mobile armor and the reformation of a new coarser armor. The breakup initially induced a fining due to the exposure of the finer substrate, which was accompanied by a sudden increase of the local sediment transport rate, followed by the formation of an armor that was coarser than the initial one. The reformation of the armor was due to the supply of coarse material from the upstream degrading reach and the presence of gravel in the original substrate sediment. Provided that the gravel supply from upstream suffices for armor reformation, armor breakup enables slope adjustment such that the new steady state is closer to normal flow conditions.


Proceedings ◽  
2019 ◽  
Vol 48 (1) ◽  
pp. 26
Author(s):  
Riccardo Zarbo ◽  
Valentina Marsili ◽  
Stefano Alvisi ◽  
Marco Franchini

Pressure reducing valves (PRVs) effectiveness for water distribution networks’ (WDNs’) optimal pressure management is proven, but problems and operational limitations have been highlighted by some recent studies. In this work, the functioning of a piston-actuated pressure reducing valve (PA-PRV), subjected to low flow regimes, is investigated by means of a laboratory test set. The results obtained highlight that the PA-PRV tends not to respect the imposed set-point value, and can present an unstable behaviour, characterised by significant pressure oscillations under some flow-rate conditions.


Author(s):  
G. Michael Fitch

Highway culverts may hinder the normal migrations of various trout species in wild trout streams through increased flow velocity, shallow water depths, increased turbulence, and perching. This can impede migrational movements, affecting the genetic diversity and long-term survival of some species. Often, the proper installation of culverts can reduce the adverse effects on fish while maintaining hydraulic efficiency. This study characterized the problems with existing culverts to develop guidelines for the future use of culverts in areas with high gradient streams. Installation criteria will ideally limit the use of bridges where culverts are appropriate, and eliminate the use of culverts where they would create fish passage problems. This will reduce installation, maintenance, and retrofitting costs. The study concluded that culverts can be considered the primary option for crossing trout streams if the culvert can be placed on the same slope as that of the streambed, the slope of the stream is less than 3 percent, the flow velocity does not exceed 1.2 m/sec under normal flow conditions, and the barrel of the culvert can be properly countersunk at the outlet to prevent perching. Bridges should be used at these crossings if any of these criteria cannot be met. The study also concluded that baffles should not be used to control streamflow velocities in newly installed culverts, and concrete aprons should not be used at culvert outlets.


Sign in / Sign up

Export Citation Format

Share Document