Imprinted zeolite modified carbon paste electrode as a selective potentiometric sensor for blood glucose

2020 ◽  
Author(s):  
Miratul Khasanah ◽  
Alfa Akustia Widati ◽  
Usreg Sri Handajani ◽  
Masfah Raudlotus Shofiyyah ◽  
Sabrina Aulia Rakhma ◽  
...  
Sensors ◽  
2021 ◽  
Vol 21 (2) ◽  
pp. 350
Author(s):  
Yaning Zhang ◽  
Zhihui Li ◽  
Xiaotong Guo ◽  
Guangzhou Liu ◽  
Shuyong Zhang

A new potentiometric sensor based on modified carbon paste electrode (CPE) was prepared for the sensitive and selective detection of total residual chlorine (TRC) in simulated electrolytically-treated ballast water (BW). The modified CPE was prepared using ferrocene (Fc) as the sensing species and paraffin oil as the binder. It is revealed that the addition of Fc can significantly shorten the response time and improve the reproducibility, selectivity, and stability of the sensor. The open circuit potential of the Fc-CPE is in linear proportion to the logarithm of TRC within the TRC concentration range from 1 mg∙dm−3 to 15 mg∙dm−3. In addition, the Fc-CPE sensor exhibits good selectivity to TRC over a wide concentration range of the possible co-exiting interference ions in seawater. The Fc-CPE electrode can be used as a convenient and reliable sensor for the continuous monitoring of TRC during the electrolytic treatment of BW.


Surfaces ◽  
2021 ◽  
Vol 4 (3) ◽  
pp. 191-204
Author(s):  
Edwin S. D’Souza ◽  
Jamballi G. Manjunatha ◽  
Chenthattil Raril ◽  
Girish Tigari ◽  
Huligerepura J. Arpitha ◽  
...  

A modest, efficient, and sensitive chemically modified electrode was fabricated for sensing curcumin (CRC) through an electrochemically polymerized titan yellow (TY) modified carbon paste electrode (PTYMCPE) in phosphate buffer solution (pH 7.0). Cyclic voltammetry (CV) linear sweep voltammetry (LSV) and differential pulse voltammetry (DPV) approaches were used for CRC detection. PTYMCPE interaction with CRC suggests that the electrode exhibits admirable electrochemical response as compared to bare carbon paste electrode (BCPE). Under the optimized circumstances, a linear response of the electrode was observed for CRC in the concentration range 2 × 10−6 M to 10 × 10−6 M with a limit of detection (LOD) of 10.94 × 10−7 M. Moreover, the effort explains that the PTYMCPE electrode has a hopeful approach for the electrochemical resolution of biologically significant compounds. Additionally, the proposed electrode has demonstrated many advantages such as easy preparation, elevated sensitivity, stability, and enhanced catalytic activity, and can be successfully applied in real sample analysis.


Sign in / Sign up

Export Citation Format

Share Document