Directional mean flow measurements using a single inclined hot wire

1975 ◽  
Vol 18 (3) ◽  
pp. 298 ◽  
Author(s):  
Z. M. Moussa ◽  
S. Eskinazi
Keyword(s):  
Hot Wire ◽  
1962 ◽  
Vol 29 (4) ◽  
pp. 615-625 ◽  
Author(s):  
W. G. Rose

A swirling jet of air is generated for this work by flow issuing from a rotating pipe into a reservoir of motionless air. At the pipe discharge, the flow is roughly a fully developed, turbulent pipe flow in solid-body rotation. Owing to the very rapid decay of the swirl, measurements are confined to a region extending from the pipe discharge out to a distance of 15 pipe diameters. Mean-velocity magnitudes and mean directions are the primary results; in addition, one turbulence intensity component is included. All velocities and intensities were measured with a constant-temperature hot-wire anemometer having a linearized response, and all mean values were determined by electronic integration. Contrasted with the nonswirling jet, the jet with swirl spreads at a larger angle, entrains reservoir fluid more rapidly, and consequently displays a more rapid reduction of mean-velocity and growth of turbulence intensity. In its gross features, at large distances from the orifice, the measured swirling jet agrees with the predictions of “weak-swirl” analyses.


The wakes of circular cylinders were explored by means of hot wire anemometers in the range of Reynolds numbers based on diameter of from 10 3 to 4 x 10 4 . The vortex strength was determined and its variation with distance downstream and with Reynolds number was investigated. The vortex strengths agree with those obtained by application of Roshko’s (1954) method to our mean flow measurements. The vortex velocity distribution assumed was that of Hoffman & Joubert (1963) which was found to agree with our measurements when slight adjustments were made in the inner core region. Vortex paths, the formation region and three dimensional effects are also discussed.


1975 ◽  
Vol 45 (1) ◽  
pp. 17-21
Author(s):  
J. M. Little ◽  
A. G. R. Sheil ◽  
J. Loewenthal ◽  
J. May ◽  
A. H. Goodman
Keyword(s):  

Author(s):  
P. Gaetani ◽  
G. Persico ◽  
V. Dossena ◽  
C. Osnaghi

An extensive experimental analysis was carried out at Politecnico di Milano on the subject of unsteady flow in high pressure (HP) turbine stages. In this paper the unsteady flow measured downstream of a modern HP turbine stage is discussed. Traverses in two planes downstream of the rotor are considered and, in one of them, the effects of two very different axial gaps are investigated: the maximum axial gap, equal to one stator axial chord, is chosen to “switch off” the rotor inlet unsteadiness, while the nominal gap, equal to 1/3 of the stator axial chord, is representative of actual engines. The experiments were performed by means of a fast-response pressure probe, allowing for two-dimensional phase-resolved flow measurements in a bandwidth of 80 kHz. The main properties of the probe and the data processing are described. The core of the paper is the analysis of the unsteady rotor aerodynamics; for this purpose, instantaneous snapshots of the rotor flow in the relative frame are used. The rotor mean flow and its interaction with the stator wakes and vortices are also described. In the outer part of the channel only the rotor cascade effects can be observed, with a dominant role played by the tip-leakage flow and by the rotor tip passage vortex. In the hub region, where the secondary flows downstream of the stator are stronger, the persistence of stator vortices is slightly visible in the maximum stator-rotor axial gap configuration, while in the minimum stator-rotor axial gap configuration the interaction with the rotor vortices dominates the flow field. A fair agreement with the wakes and vortices transport models has been achieved. A discussion of the interaction process is reported giving particular emphasis to the effects of the different cascade axial gaps. Some final considerations on the effects of the different axial gap over the stage performances are reported.


2006 ◽  
Vol 21 (6) ◽  
pp. 379-382 ◽  
Author(s):  
Michael Blaivas ◽  
Stephen Shiver ◽  
Matthew Lyon ◽  
Srikar Adhikari

AbstractIntroduction:Exsanguination from a femoral artery wound can occur in sec-onds and may be encountered more often due to increased use of body armor. Some military physicians teach compression of the distal abdominal aorta (Abdominal Aorta) with a knee or a fist as a temporizing measure.Objective:The objective of this study was to evaluate if complete collapse of the Abdominal Aorta was feasible and with what weight it occurs.Methods:This was a prospective, interventional study at a Level-I, academ-ic, urban, emergency department with an annual census of 80,000 patients. Written, informed consent was obtained from nine male volunteers after Institutional Research Board approval. Any patient who presented with abdominal pain or had undergone previous abdominal surgery was excluded from the study. Subjects were placed supine on the floor to simulate an injured soldier. Various dumbbells of increasing weight were placed over the distal Abdominal Aorta, and pulsed-wave Doppler measurements were taken at the right common femoral artery (CFA). Dumbbells were placed on top of a tightly bundled towel roughly the surface area of an adult knee. Flow measurements at the CFA were taken at increments of 20 pounds. This was repeated with weight over the proximal right artery iliac and distal right iliac artery to eval- uate alternate sites. Descriptive statistics were utilized to evaluate the data.Results:The mean velocity through the CFA was 75.8 cm/ sec at 0 pounds. Compression of the Abdominal Aorta ranging 80 to 140 pounds resulted in no flow in the CFA. A steady decrease in mean flow velocity was seen starting with 20 pounds. Flow velocity decreased more rapidly with compression of the prox- imal right iliac artery, and stopped in all nine volunteers by 120 pounds of pressure. For all nine volunteers, up to 80 pounds of pressure over the distal iliac artery failed to decrease CFA flow velocity, and no subject was able to tolerate more weight at that location.Conclusion:Flow to the CFA can be stopped completely with pressure over the distal Abdominal Aorta or proximal iliac artery in catastrophic wounds. Compression over the proximal iliac artery worked best, but a first responder still may need to apply upward of 120 pounds of pressure to stop exsanguination.


Author(s):  
Roger W. Ainsworth ◽  
John L. Allen ◽  
J. Julian M. Batt

The advent of a new generation of transient rotating turbine simulation facilities, where engine values of Reynolds and Mach number are matched simultaneously together with the relevant rotational parameters for dimensional similitude (Dunn et al [1988], Epstein et al [1984]. Ainsworth et al [1988]), has provided the stimulus for developing improved instrumentation for investigating the aerodynamic flows in these stages. Much useful work has been conducted in the past using hot-wire and laser anemometers. However, hot-wire anemometers are prone to breakage in the high pressure flows required for correct Reynolds numbers, Furthermore some laser techniques require a longer runtime than these transient facilites permit, and generally yield velocity information only, giving no data on loss production. Advances in semiconductor aerodynamic probes are beginning to fulfil this perceived need. This paper describes advances made in the design, construction, and testing of two and three dimensional fast response aerodynamic probes, where semiconductor pressure sensors are mounted directly on the surface of the probes, using techniques which have previously been successfully used on the surface of rotor blades (Ainsworth, Dietz and Nunn [1991]). These are to be used to measure Mach number and flow direction in compressible unsteady flow regimes. In the first section, a brief review is made of the sensor and associated technology which has been developed to permit a flexible design of fast response aerodynamic probe. Following this, an extensive programme of testing large scale aerodynamic models of candidate geometries for suitable semiconductor scale probes is described, and the results of these discussed. The conclusions of these experiments, conducted for turbine representative mean and unsteady flows, yielded new information for optimising the design of the small scale semiconductor probes, in terms of probe geometry, sensor placement, and aerodynamic performance. Details are given of a range of wedge and pyramid semiconductor probes constructed, and the procedures used in calibrating and making measurements with them. Differences in performance are discussed, allowing the experimenter to choose an appropriate probe for the particular measurement required. Finally, the application of prototype semiconductor probes in a transient rotor experiment at HP turbine representative conditions is described, and the data so obtained is compared with (PD solutions of the unsteady viscous flow-field.


2016 ◽  
Vol 796 ◽  
pp. 257-284 ◽  
Author(s):  
Christian J. Kähler ◽  
Sven Scharnowski ◽  
Christian Cierpka

The understanding and accurate prediction of turbulent flow separation on smooth surfaces is still a challenging task because the separation and the reattachment locations are not fixed in space and time. Consequently, reliable experimental data are essential for the validation of numerical flow simulations and the characterization and analysis of the complex flow physics. However, the uncertainty of the existing near-wall flow measurements make a precise analysis of the near-wall flow features, such as separation/reattachment locations and other predicted near-wall flow features which are under debate, often impossible. Therefore, the periodic hill experiment at TU Munich (ERCOFTAC test case 81) was repeated using high resolution particle image velocimetry and particle tracking velocimetry. The results confirm the strong effect of the spatial resolution on the near-wall flow statistics. Furthermore, it is shown that statistically stable values of the turbulent flow variables can only be obtained for averaging times which are challenging to realize with highly resolved large eddy simulation and direct numerical simulation techniques. Additionally, the analysis implies that regions of correlated velocity fluctuations with rather uniform streamwise momentum exist in the flow. Their size in the mean flow direction can be larger than the hill spacing. The possible impact of the correlated turbulent motion on the wake region is discussed, as this interaction might be important for the understanding and control of the flow separation dynamics on smooth bodies.


1994 ◽  
Vol 116 (4) ◽  
pp. 586-596 ◽  
Author(s):  
P. L. Andrew ◽  
Wing-fai Ng

The turbulent character of the supersonic wake of a linear cascade of fan airfoils has been studied using a two-component laser-doppler anemometer. The cascade was tested in the Virginia Polytechnic Institute and State University intermittent wind tunnel facility, where the Mach and Reynolds numbers were 2.36 and 4.8 × 106, respectively. In addition to mean flow measurements, Reynolds normal and shear stresses were measured as functions of cascade incidence angle and streamwise locations spanning the near-wake and the far-wake. The extremities of profiles of both the mean and turbulent wake properties´ were found to be strongly influenced by upstream shock-boundary -layer interactions, the strength of which varied with cascade incidence. In contrast, the peak levels of turbulence properties within the shear layer were found to be largely independent of incidence, and could be characterized in terms of the streamwise position only. The velocity defect turbulence level was found to be 23 percent, and the generally accepted value of the turbulence structural coefficient of 0.30 was found to be valid for this flow. The degree of similarity of the mean flow wake profiles was established, and those profiles demonstrating the most similarity were found to approach a state of equilibrium between the mean and turbulent properties. In general, this wake flow may be described as a classical free shear flow, upon which the influence of upstream shock-boundary-layer interactions has been superimposed.


1981 ◽  
Vol 103 (2) ◽  
pp. 445-450
Author(s):  
M. L. Billet

As part of a study on the structure of a trailing vortex, laser doppler anemometer (LDA) measurements were made of the flow field near an open rotor having an inlet velocity gradient. The measurements were made in the 1.22 m dia water tunnel of the Applied Research Laboratory at The Pennsylvania State University. Velocity data were obtained for rotor inlet and outlet flow fields for several different inlet velocity gradients. Velocity data were also obtained downstream of the rotor plane that shows the vortex structure. Flow field measurements show the development of the downstream vortex motion. Small variations in the inlet velocity gradient near the rotor wall caused large differences in the structure of the trailing vortex. In addition, a measured downstream velocity profile is compared with a calculated velocity profile.


Sign in / Sign up

Export Citation Format