scholarly journals Effect of sample temperature on time-resolved laser-induced breakdown spectroscopy

AIP Advances ◽  
2019 ◽  
Vol 9 (6) ◽  
pp. 065214 ◽  
Author(s):  
Kaimin Guo ◽  
Anmin Chen ◽  
Wanpeng Xu ◽  
Dan Zhang ◽  
Mingxing Jin
1992 ◽  
Vol 46 (9) ◽  
pp. 1382-1387 ◽  
Author(s):  
J. A. Aguilera ◽  
C. Aragón ◽  
J. Campos

Laser-induced breakdown spectroscopy has been used to determine carbon content in steel. The plasma was formed by focusing a Nd:YAG laser on the sample surface. With the use of time-resolved spectroscopy and generation of the plasma in nitrogen atmosphere, a precision of 1.6% and a detection limit of 65 ppm have been obtained. These values are similar to those of other accurate conventional techniques. Matrix effects for the studied steels are reduced to a small slope difference between the calibration curves for stainless and nonstainless steels.


2007 ◽  
Vol 62 (12) ◽  
pp. 1329-1334 ◽  
Author(s):  
Matthieu Baudelet ◽  
Myriam Boueri ◽  
Jin Yu ◽  
Samuel S. Mao ◽  
Vincent Piscitelli ◽  
...  

2019 ◽  
Vol 34 (12) ◽  
pp. 2378-2384 ◽  
Author(s):  
Ran Hai ◽  
Zhonglin He ◽  
Ding Wu ◽  
Weina Tong ◽  
Harse Sattar ◽  
...  

During laser ablation, the spectral emission intensity, plasma temperature and electron density increased significantly with increasing sample temperature.


2019 ◽  
Vol 34 (3) ◽  
pp. 607-615 ◽  
Author(s):  
V. N. Lednev ◽  
M. Ya. Grishin ◽  
P. A. Sdvizhenskii ◽  
R. D. Asyutin ◽  
R. S. Tretyakov ◽  
...  

The influence of sample temperature on the laser ablation process and analytical capabilities of laser induced breakdown spectroscopy (LIBS) was studied systematically.


2008 ◽  
Vol 62 (10) ◽  
pp. 1137-1143 ◽  
Author(s):  
Dário Santos ◽  
Ricardo Elgul Samad ◽  
Lílian Cristina Trevizan ◽  
Anderson Zanardi de Freitas ◽  
Nilson Dias Vieira ◽  
...  

The aim of this work was to evaluate the performance of femtosecond laser-induced breakdown spectroscopy (fs-LIBS) for the determination of elements in animal tissues. Sample pellets were prepared from certified reference materials, such as liver, kidney, muscle, hepatopancreas, and oyster, after cryogenic grinding assisted homogenization. Individual samples were placed in a two-axis computer-controlled translation stage that moved in the plane orthogonal to a beam originating from a Ti:Sapphire chirped-pulse amplification (CPA) laser system operating at 800 nm and producing a train of 840 μJ and 40 fs pulses at 90 Hz. The plasma emission was coupled into the optical fiber of a high-resolution intensified charge-coupled device (ICCD)–echelle spectrometer. Time-resolved characteristics of the laser-produced plasmas showed that the best results were obtained with delay times between 80 and 120 ns. Data obtained indicate both that it is a matrix-independent sampling process and that fs-LIBS can be used for the determination of Ca, Cu, Fe, K, Mg, Na, and P, but efforts must be made to obtain more appropriate detection limits for Al, Sr, and Zn.


1996 ◽  
Vol 50 (7) ◽  
pp. 880-884 ◽  
Author(s):  
Andrew V. Pakhomov ◽  
William Nichols ◽  
Jacek Borysow

Time-resolved laser-induced breakdown spectroscopy was applied for quantitative measurement of lead content in concrete at levels down to 10 ppm. The breakdown was formed at the sample surface by a Q-switched ND:YAG laser operating at a 1.06-μm wavelength and a repetition rate of 10 Hz. Contamination levels were inferred from the ratio of the integrated emission line of lead to a known reference line of the matrix. The lead contamination can be determined on an absolute scale down to 10 ppm at an optimum delay time of 3.0 μs. These results were derived from analysis of the temporal evolution of the calibration function within a 0.1- to 19.0-μs time range. The calibration function exhibits no dependence on the incident laser pulse energy, which was varied from 250 to 400 mJ.


Sign in / Sign up

Export Citation Format

Share Document