scholarly journals Multi-scale multi-dimensional imaging at I13-coherence branchline in diamond light source

Author(s):  
Silvia Cipiccia ◽  
D. Batey ◽  
X. Shi ◽  
S. Williams ◽  
K. Wanelik ◽  
...  
Keyword(s):  
2021 ◽  
Author(s):  
Yuanzhi Wang ◽  
Tao Lu ◽  
Yanduo Zhang ◽  
Yuntao Wu
Keyword(s):  

Author(s):  
Wenxuan Jia ◽  
Debbie Leung ◽  
Huachao Mao ◽  
Han Xu ◽  
Chi Zhou ◽  
...  

Abstract Microscale surface structures are commonly found on macroscale bodies of natural creatures for their unique functions. However, it is difficult to fabricate such multi-scale geometry with conventional stereolithography processes that rely on either laser or digital micromirror device (DMD). More specifically, the DMD-based mask projection method displays the image of a cross-section of the part on the resin to fabricate the entire layer efficiently; however, its display resolution is limited by the building area. In comparison, the laser-based vector scanning method builds smooth features using a focused laser beam with desired beam-width resolution; however, it has less throughput for its sequential nature. In this paper, we studied the hybrid-light-source stereolithography process that integrates both optical light sources to facilitate the fabrication of macro-objects with microscale surface structures (called micro-textures in the paper). The hardware system uses a novel calibration approach that ensures pixel-level dimensional accuracy across the two light sources. The software system enables designing the distribution and density of specific microscale textures on a macro-object by generating projection images and laser toolpaths for the two integrated light sources. Several test cases were fabricated to demonstrate the capability of the developed process. A large fabrication area (76.8 mm × 80.0 mm) with 50 µm microfeatures can be achieved with a high throughput.


Author(s):  
Christoph Rau ◽  
Malte Storm ◽  
Shashidhara Marathe ◽  
Andrew J. Bodey ◽  
Marie-Christine Zdora ◽  
...  
Keyword(s):  

Author(s):  
Michael T. Bucek ◽  
Howard J. Arnott

It is believed by the authors, with supporting experimental evidence, that as little as 0.5°, or less, knife clearance angle may be a critical factor in obtaining optimum quality ultrathin sections. The degree increments located on the knife holder provides the investigator with only a crude approximation of the angle at which the holder is set. With the increments displayed on the holder one cannot set the clearance angle precisely and reproducibly. The ability to routinely set this angle precisely and without difficulty would obviously be of great assistance to the operator. A device has been contrived to aid the investigator in precisely setting the clearance angle. This device is relatively simple and is easily constructed. It consists of a light source and an optically flat, front surfaced mirror with a minute black spot in the center. The mirror is affixed to the knife by placing it permanently on top of the knife holder.


Author(s):  
P.M. Houpt ◽  
A. Draaijer

In confocal microscopy, the object is scanned by the coinciding focal points (confocal) of a point light source and a point detector both focused on a certain plane in the object. Only light coming from the focal point is detected and, even more important, out-of-focus light is rejected.This makes it possible to slice up optically the ‘volume of interest’ in the object by moving it axially while scanning the focused point light source (X-Y) laterally. The successive confocal sections can be stored in a computer and used to reconstruct the object in a 3D image display.The instrument described is able to scan the object laterally with an Ar ion laser (488 nm) at video rates. The image of one confocal section of an object can be displayed within 40 milliseconds (1000 х 1000 pixels). The time to record the total information within the ‘volume of interest’ normally depends on the number of slices needed to cover it, but rarely exceeds a few seconds.


2018 ◽  
Vol 32 (4) ◽  
pp. 182-190 ◽  
Author(s):  
Kenta Matsumura ◽  
Koichi Shimizu ◽  
Peter Rolfe ◽  
Masanori Kakimoto ◽  
Takehiro Yamakoshi

Abstract. Pulse volume (PV) and its related measures, such as modified normalized pulse volume (mNPV), direct-current component (DC), and pulse rate (PR), derived from the finger-photoplethysmogram (FPPG), are useful psychophysiological measures. Although considerable uncertainties exist in finger-photoplethysmography, little is known about the extent of the adverse effects on the measures. In this study, we therefore examined the inter-method reliability of each index across sensor positions and light intensities, which are major disturbance factors of FPPG. From the tips of the index fingers of 12 participants in a resting state, three simultaneous FPPGs having overlapping optical paths were recorded, with their light intensity being changed in three steps. The analysis revealed that the minimum values of three coefficients of Cronbach’s α for ln PV, ln mNPV, ln DC, and PR across positions were .948, .850, .922, and 1.000, respectively, and that those across intensities were .774, .985, .485, and .998, respectively. These findings suggest that ln mNPV and PR can be used for psychophysiological studies irrespective of minor differences in sensor attachment positions and light source intensity, whereas and ln DC can also be used for such studies but under the condition of light intensity being fixed.


2003 ◽  
Vol 104 ◽  
pp. 557-561 ◽  
Author(s):  
M. R. Howells ◽  
H. Chapman ◽  
S. Hau-Riege ◽  
H. He ◽  
S. Marchesini ◽  
...  

Sign in / Sign up

Export Citation Format