Pressure drop for adiabatic air-water flow through a time-varying constriction

2018 ◽  
Vol 30 (10) ◽  
pp. 101901 ◽  
Author(s):  
A. Van Hirtum ◽  
A. Bouvet ◽  
X. Pelorson
1986 ◽  
Vol 64 (3) ◽  
pp. 387-392 ◽  
Author(s):  
B. H. Chen ◽  
N. S. Yang ◽  
A. F. Mcmillan

2008 ◽  
Vol 2 (4) ◽  
pp. 482-495 ◽  
Author(s):  
S. P. Asok ◽  
K. Sankaranarayanasamy ◽  
T. Sundararajan ◽  
P. Starwin ◽  
R. Kalieswaran ◽  
...  

1974 ◽  
Vol 16 (5) ◽  
pp. 353-355 ◽  
Author(s):  
D. Chisholm ◽  
D. H. Rooney

A method of predicting the pressure drop during steam/water flow through orifices is presented, which extends an existing procedure to give improved agreement with experiment at conditions of low dryness fraction.


2017 ◽  
Vol 23 (1) ◽  
pp. 57-66
Author(s):  
Tatjana Kaludjerovic-Radoicic ◽  
Nevenka Boskovic-Vragolovic ◽  
Radmila Garic-Grulovic ◽  
Mihal Djuris ◽  
Zeljko Grbavcic

The aim of this work was the experimental evaluation of different friction factor correlations for water flow through packed beds of spherical and non-spherical particles at ambient temperature. The experiments were performed by measuring the pressure drop across the bed. Packed beds made of monosized glass spherical particles of seven different diameters were used, as well as beds made of 16 fractions of quartz filtration sand obtained by sieving (polydisperse non-spherical particles). The range of bed voidages was 0.359?0.486, while the range of bed particle Reynolds numbers was from 0.3 to 286 for spherical particles and from 0.1 to 50 for non-spherical particles. The obtained results were compared using a number of available literature correlations. In order to improve the correlation results for spherical particles, a new simple equation was proposed in the form of Ergun?s equation, with modified coefficients. The new correlation had a mean absolute deviation between experimental and calculated values of pressure drop of 9.04%. For non-spherical quartz filtration sand particles the best fit was obtained using Ergun?s equation, with a mean absolute deviation of 10.36%. Surface-volume diameter (dSV) necessary for correlating the data for filtration sand particles was calculated based on correlations for dV = f(dm) and ? = f(dm).


Author(s):  
C. O. Ríos Orozco ◽  
N. C. Uzarraga-Rodriguez ◽  
A. Gallegos-Muñoz ◽  
J. M. Riesco Ávila

In this work the characterization of the water flow through a flat solar collector and solar collectors systems interconnected is presented. This allows analyzing the behavior of flow distribution in the headers pipe and riser tubes of flat solar collectors. The hydraulic analysis allows determining if the water flow inside the risers presents a no-uniform distribution, having that the mass flow rate through riser tubes increases when they are located a greater distance from inlet of header pipe. This effect also occurs at system composed of several solar collectors interconnected, through their own header pipes, which behaves like a simple flat solar collector with header pipe longer and major number of riser tubes. The hydraulic model of the water flow through a flat solar collector, equipped with different number of riser tubes, is modeled in the FLUENT® software and comparing with theory and methodology knowing for the calculation of pressure drop in pipe sections and accessories. The results show the curves obtained for hydraulic behavior for the cases of study, where is observed that the water flow is no-uniform. This no uniformity provokes that the friction coefficient varies depending of the position of riser tube.


1970 ◽  
Author(s):  
B. A. Zenkevich ◽  
P. L. Kirillov ◽  
G. V. Alekseev ◽  
O. L. Peskov ◽  
O. A. Sudnitsyn