A method for coincidence timing resolution enhancement

2016 ◽  
Vol 87 (5) ◽  
pp. 053504 ◽  
Author(s):  
E. E. Ermis ◽  
C. Celiktas ◽  
E. Pilicer
2011 ◽  
Vol 418-420 ◽  
pp. 922-927
Author(s):  
Weerapong Chewpraditkul ◽  
Chalerm Wanarak ◽  
Marek Moszynski ◽  
Lukasz Swiderski

The performances of Ce-doped Lu3Al5O12(LuAG:Ce) and LaBr3(LaBr3:Ce) scintillators were compared for γ-ray detection using photomultiplier tube ( XP5500B PMT) readout. For 662 keV γ-rays (137Cs source), an energy resolution of 3.5% obtained for LaBr3:Ce is much better than that of 6.7% obtained for LuAG:Ce, while the estimated photofraction of 28.0% for LuAG:Ce is higher than that of 16.2% for LaBr3:Ce. The light yield non-proportionality and energy resolution versus γ-ray energy were measured and the intrinsic resolution of the crystals was calculated. The coincidence timing resolution, obtained in this work for 511 keV annihilation quanta, was 583 ps and 204 ps, respectively, for LuAG:Ce –BaF2and LaBr3:Ce – BaF2detectors.


2021 ◽  
Vol 11 (16) ◽  
pp. 7548
Author(s):  
Luca Presotto ◽  
Valentino Bettinardi ◽  
Elisabetta De Bernardi

Background: Time-of-Flight (TOF) is a leading technological development of Positron Emission Tomography (PET) scanners. It reduces noise at the Maximum-Likelihood solution, depending on the coincidence–timing–resolution (CTR). However, in clinical applications, it is still not clear how to best exploit TOF information, as early stopped reconstructions are generally used. Methods: A contrast-recovery (CR) matching rule for systems with different CTRs and non-TOF systems is theoretically derived and validated using (1) digital simulations of objects with different contrasts and background diameters, (2) realistic phantoms of different sizes acquired on two scanners with different CTRs. Results: With TOF, the CR matching rule prescribes modifying the iterations number by the CTRs ratio. Without TOF, the number of iterations depends on the background dimension. CR matching was confirmed by simulated and experimental data. With TOF, image noise followed the square root of the CTR when the rule was applied on simulated data, while a significant reduction was obtained on phantom data. Without TOF, preserving the CR on larger objects significantly increased the noise. Conclusions: TOF makes PET reconstructions less dependent on background dimensions, thus, improving the quantification robustness. Better CTRs allows performing fewer updates, thus, maintaining accuracy while minimizing noise.


Author(s):  
Eric S. Harmon ◽  
Michael O. Thompson ◽  
Charles Ross Schmidtlein ◽  
James N. Turner ◽  
Andrzej Krol

2000 ◽  
Author(s):  
Yiping Shao ◽  
H. Bradford Barber ◽  
Stephen J. Balzer ◽  
Simon R. Cherry

2011 ◽  
Vol 284-286 ◽  
pp. 2064-2069
Author(s):  
Weerapong Chewpraditkul ◽  
Chalerm Wanarak ◽  
Marek Moszynski ◽  
Tomasz Szczesniak ◽  
Lukasz Swiderski

The scintillation properties of Lu1.8Y0.2SiO5:Ce (LYSO:Ce) and LaCl3:Ce scintillators were studied under g-ray excitation. For 662 keV g-rays (137Cs source), energy resolution of 4.5% obtained for LaCl3:Ce coupled to XP5200B PMT is much better than that of 8.2% for LYSO:Ce. The estimated photofraction of 26.1% at 662 keV for LYSO:Ce is higher than that of 15.7 % for LaCl3:Ce. The non-proportionality of the light yield and energy resolution versus g-ray energy were measured and the intrinsic resolution of the crystals was calculated. The coincidence timing resolution, obtained in this work for 511 keV annihilation quanta, was 222 and 229 ps, respectively, for LYSO:Ce – and LaCl3:Ce – based detectors in coincidence with a BaF2detector.


Author(s):  
J.K. Weiss ◽  
M. Gajdardziska-Josifovska ◽  
M. R. McCartney ◽  
David J. Smith

Interfacial structure is a controlling parameter in the behavior of many materials. Electron microscopy methods are widely used for characterizing such features as interface abruptness and chemical segregation at interfaces. The problem for high resolution microscopy is to establish optimum imaging conditions for extracting this information. We have found that off-axis electron holography can provide useful information for the study of interfaces that is not easily obtained by other techniques.Electron holography permits the recovery of both the amplitude and the phase of the image wave. Recent studies have applied the information obtained from electron holograms to characterizing magnetic and electric fields in materials and also to atomic-scale resolution enhancement. The phase of an electron wave passing through a specimen is shifted by an amount which is proportional to the product of the specimen thickness and the projected electrostatic potential (ignoring magnetic fields and diffraction effects). If atomic-scale variations are ignored, the potential in the specimen is described by the mean inner potential, a bulk property sensitive to both composition and structure. For the study of interfaces, the specimen thickness is assumed to be approximately constant across the interface, so that the phase of the image wave will give a picture of mean inner potential across the interface.