Effect of varying inspection parameters in crack depth measurements using potential drop method

Author(s):  
David Utrata ◽  
Darrel A. Enyart
1991 ◽  
Vol 47 (1) ◽  
pp. 25-38 ◽  
Author(s):  
K. Ikeda ◽  
M. Yoshimi ◽  
C. Miki

2021 ◽  
Vol 2091 (1) ◽  
pp. 012047
Author(s):  
P N Shkatov

Abstract Traditional measuring techniques often lead to errors due to the need to register signals in both defective and defect-free areas. In this paper, we introduce an alternating current potential drop technique with detuning from the influence of variations in the electromagnetic properties of the metal achieved by registering a signal only at the defective site. We show that, with an appropriate choice of measurement parameters, the use of the proposed technique leads to an increase in sensitivity to the crack depth as well as to an increase in the measurement range.


2018 ◽  
Vol 165 ◽  
pp. 09004
Author(s):  
Thomas M Buss ◽  
James P Rouse ◽  
Christopher J Hyde ◽  
Seamus D Garvey

Crack size determination using electrical potentials both in service and in the laboratory has been undertaken for many years. In the laboratory this has mainly concentrated on the measurement of crack depth, with either alternating current (AC) or direct current (DC) supplies. Some work to determine the varying depth along the width of cracks as an inspection tool of in service parts using mapping methods has been done. This has used both AC and DC utilising various models to understand the data recorded, in Alternating Current Potential Drop (ACPD) a range of frequencies have been used to give various skin depths. The resulting analyses have been grouped into two groups 'thin skin' and 'thick skin', in the thin skin case the skin depth is significantly smaller than the depth of the crack 1/10th of the crack depth whereas in the thick skin cases are for cases where skin depth is over this limit. Some work has been carried out to try and unify these two approaches. The work presented here looks to develop a method using variable frequency ACPD to resolve further information about cracks growing in laboratory specimens. A system has been developed to rapidly sweep a wide frequency band and record voltage drop across a crack or feature. A selection of steel samples with known geometries and features have been used to trial and benchmark the technique. These samples have a range of cross sections as well as machined features or a range of shapes and sizes to simulate a range of crack geometries. This work has been approximated using a 2D computational model. This has been done using a reduced thickness approach.


Sign in / Sign up

Export Citation Format

Share Document