Portable double-sided laser-heating system for Mössbauer spectroscopy and X-ray diffraction experiments at synchrotron facilities with diamond anvil cells

2012 ◽  
Vol 83 (12) ◽  
pp. 124501 ◽  
Author(s):  
I. Kupenko ◽  
L. Dubrovinsky ◽  
N. Dubrovinskaia ◽  
C. McCammon ◽  
K. Glazyrin ◽  
...  
2002 ◽  
Vol 66 (3) ◽  
pp. 421-430 ◽  
Author(s):  
J. C. Waerenborgh ◽  
J. Figueiras ◽  
A. Mateus ◽  
M. Gonçalves

AbstractIlmenites from the least-altered rocks of the Beja-Acebuches Ophiolite Complex (SE Portugal), with low Ti values and excess Fe, despite rare optical evidence of hematite exsolution, were studied by 57Fe Mössbauer spectroscopy and X-ray diffraction. According to single-crystal XRD the sequence of alternate layers characteristic of the ideal ilmenite structure is preserved, the excess Fe being accommodated in the Ti layers. No superparamagnetic oxides were detected by 57Fe Mössbauer spectroscopy. The typical spectra of bulk αFe2O3 and of Fe3+-containing ilmenite, in the paramagnetic state above 49 K and magnetically ordered at 6 K, are observed. The average degree of oxidation of the ilmenites, estimated from the chemical analysis assuming ideally stoichiometric full cation site occupancies, is also confirmed by 57Fe Mössbauer data. Since our crystal chemistry study gave no evidence of crypto-exsolution textures within the ilmenite with the observed compositions, fast cooling from magmatic temperatures and decomposition of ilmenite in supergene conditions is suggested.


2001 ◽  
Vol 13 (1) ◽  
pp. 136-140 ◽  
Author(s):  
Tianrong Cheng ◽  
Robert Bereman ◽  
Eddy De Grave ◽  
Larry H. Bowen

Author(s):  
Amel Kaibi ◽  
Abderrahim Guittoum ◽  
Nassim Souami ◽  
Mohamed Kechouane

Nanocrystalline Ni75Fe25 (Ni3Fe) powders were prepared by mechanical alloying process using a vario-planetary high-energy ball mill. The intermetallic Ni3Fe formation and different physical properties were investigated, as a function of milling time, t, (in the range 6 to 96 h range), using X-Ray Diffraction (XRD) and Mössbauer Spectroscopy techniques. X-ray diffraction were performed on the samples to understand the structural characteristics and get information about elements and phases present in the powder after different time of milling. The refinement of XRD spectra revealed the complete formation of fcc Ni (Fe) disordered solid solution after 24 h of milling time, the Fe and Ni elemental distributions are closely correlated. With increasing the milling time, the lattice parameter increases and the grains size decreases. The Mössbauer experiments were performed on the powders in order to follow the formation of Ni3Fe compound as a function of milling time. From the adjustment of Mössbauer spectra, we extracted the hyperfine parameters. The evolution of hyperfine magnetic field shows that the magnetic disordered Ni3Fe phase starts to form from 6 h of milling time and grow in intensity with milling time. For the milling time more than 24 h, only the Ni3Fe disordered phase is present with a mean hyperfine magnetic field of about 29.5 T. The interpretation of the Mossbauer spectra confirmed the results obtained by XRD.


2021 ◽  
Vol 28 (6) ◽  
Author(s):  
Zuzana Konôpková ◽  
Wolfgang Morgenroth ◽  
Rachel Husband ◽  
Nico Giordano ◽  
Anna Pakhomova ◽  
...  

A laser heating system for samples confined in diamond anvil cells paired with in situ X-ray diffraction measurements at the Extreme Conditions Beamline of PETRA III is presented. The system features two independent laser configurations (on-axis and off-axis of the X-ray path) allowing for a broad range of experiments using different designs of diamond anvil cells. The power of the continuous laser source can be modulated for use in various pulsed laser heating or flash heating applications. An example of such an application is illustrated here on the melting curve of iron at megabar pressures. The optical path of the spectroradiometry measurements is simulated with ray-tracing methods in order to assess the level of present aberrations in the system and the results are compared with other systems, that are using simpler lens optics. Based on the ray-tracing the choice of the first achromatic lens and other aspects for accurate temperature measurements are evaluated.


Sign in / Sign up

Export Citation Format

Share Document