Numerical Study on the Turbulent Flow Structures of a Buoyant Pool Fire

2010 ◽  
Author(s):  
Sherman C. P. Cheung ◽  
Camby M. K. Se ◽  
G. H. Yeoh ◽  
Jiyuan Tu ◽  
Jane W. Z. Lu ◽  
...  
Author(s):  
Ian K. Jennions ◽  
Thomas P. Sommer ◽  
Vladimir Vasiliev

An arrangement for transferring air from a stationary to a rotating system, proposed several years ago by the Saturn Design and Manufacturing Corporation (Moscow, Russia), has been studied numerically. The 3-D turbulent flow was calculated using a commercial CFD code which allowed identification of the major flow structures in this complex rotating flow. The calculations were compared with the available experimental data and show the ability of CFD to predict the integral characteristics with reasonable accuracy. An hydraulic model for performance predictions was developed and is also presented.


Author(s):  
Peng Zhang ◽  
Yu Rao ◽  
Yanlin Li

This paper presents a numerical study on turbulent flow and heat transfer in the channels with a novel hybrid cooling structure with miniature V-shaped ribs and dimples on one wall. The heat transfer characteristics, pressure loss and turbulent flow structures in the channels with the rib-dimples with three different rib heights of 0.6 mm, 1.0 mm and 1.5 mm are obtained for the Reynolds numbers ranging from 18,700 to 60,000 by numerical simulations, which are also compared with counterpart of a pure dimpled and pure V ribbed channel. The results show that the overall Nusselt numbers of the V rib-dimple channel with the rib height of 1.5 mm is up to 70% higher than that of the channels with pure dimples. The numerical simulations show that the arrangement of the miniature V rib upstream each dimple induces complex secondary flow near the wall and generates downwashing vortices, which intensifies the flow mixing and turbulent kinetic energy in the dimple, resulting in significant improvement in heat transfer enhancement and uniformness.


2017 ◽  
Vol 41 (5) ◽  
pp. 771-786 ◽  
Author(s):  
Ashif Perwez ◽  
Shreyak Shende ◽  
Rakesh Kumar

An experimental and numerical investigation is performed to study the effect of dimple and protrusion geometry on the heat transfer enhancement and the friction factor of surfaces with dimples and protrusions subjected to turbulent flow. The parameters used to compare the spherical dimples and protrusions are Nusselt Number, friction factor, and flow pattern. These parameters are obtained for a Reynolds number of 10500-60900. The spherical dimple results showed the greater heat transfer, which is about 6.97% higher and pressure loss which is 5.07% lower than the spherical protrusion. The realistic heat transfer augmentation capabilities of channels with dimples and protrusions can be studied from the experimental results. The comparison is made with respect to the smooth rectangular channel under the same flow and thermal boundary conditions. The numerical analysis is performed which shows the different vortex flow structures of the spherical dimples and protrusions channel.


2007 ◽  
Vol 11 (4) ◽  
pp. 171-178
Author(s):  
Khalid Alammar

Using the standard k-e turbulence model, an incompressible, axisymmetric turbulent flow with a sudden expansion was simulated. Effect of Prandtl number on heat transfer characteristics downstream of the expansion was investigated. The simulation revealed circulation downstream of the expansion. A secondary circulation (corner eddy) was also predicted. Reattachment was predicted at approximately 10 step heights. Corresponding to Prandtl number of 7.0, a peak Nusselt number 13 times the fully-developed value was predicted. The ratio of peak to fully-developed Nusselt number was shown to decrease with decreasing Prandtl number. Location of maximum Nusselt number was insensitive to Prandtl number.


1998 ◽  
Author(s):  
V. Riabov ◽  
I. Yegorov ◽  
D. Ivanov ◽  
H. Legner

Sign in / Sign up

Export Citation Format

Share Document