High‐voltage, high‐resolution electron microscopes

Physics Today ◽  
1974 ◽  
Vol 27 (5) ◽  
pp. 17-18
Author(s):  
Gloria B. Lubkin
Author(s):  
J.M. Cowley

By extrapolation of past experience, it would seem that the future of ultra-high resolution electron microscopy rests with the advances of electron optical engineering that are improving the instrumental stability of high voltage microscopes to achieve the theoretical resolutions of 1Å or better at 1MeV or higher energies. While these high voltage instruments will undoubtedly produce valuable results on chosen specimens, their general applicability has been questioned on the basis of the excessive radiation damage effects which may significantly modify the detailed structures of crystal defects within even the most radiation resistant materials in a period of a few seconds. Other considerations such as those of cost and convenience of use add to the inducement to consider seriously the possibilities for alternative approaches to the achievement of comparable resolutions.


Author(s):  
J.L. Batstone ◽  
J.M. Gibson ◽  
Alice.E. White ◽  
K.T. Short

High resolution electron microscopy (HREM) is a powerful tool for the determination of interface atomic structure. With the previous generation of HREM's of point-to-point resolution (rpp) >2.5Å, imaging of semiconductors in only <110> directions was possible. Useful imaging of other important zone axes became available with the advent of high voltage, high resolution microscopes with rpp <1.8Å, leading to a study of the NiSi2 interface. More recently, it was shown that images in <100>, <111> and <112> directions are easily obtainable from Si in the new medium voltage electron microscopes. We report here the examination of the important Si/Si02 interface with the use of a JEOL 4000EX HREM with rpp <1.8Å, in a <100> orientation. This represents a true structural image of this interface.


Author(s):  
John L. Hutchison

Over the past five years or so the development of a new generation of high resolution electron microscopes operating routinely in the 300-400 kilovolt range has produced a dramatic increase in resolution, to around 1.6 Å for “structure resolution” and approaching 1.2 Å for information limits. With a large number of such instruments now in operation it is timely to assess their impact in the various areas of materials science where they are now being used. Are they falling short of the early expectations? Generally, the manufacturers’ claims regarding resolution are being met, but one unexpected factor which has emerged is the extreme sensitivity of these instruments to both floor-borne and acoustic vibrations. Successful measures to counteract these disturbances may require the use of special anti-vibration blocks, or even simple oil-filled dampers together with springs, with heavy curtaining around the microscope room to reduce noise levels. In assessing performance levels, optical diffraction analysis is becoming the accepted method, with rotational averaging useful for obtaining a good measure of information limits. It is worth noting here that microscope alignment becomes very critical for the highest resolution.In attempting an appraisal of the contributions of intermediate voltage HREMs to materials science we will outline a few of the areas where they are most widely used. These include semiconductors, oxides, and small metal particles, in addition to metals and minerals.


1997 ◽  
Vol 3 (S2) ◽  
pp. 363-364
Author(s):  
R. Alani ◽  
R.J. Mitro ◽  
C.M. Tabatt ◽  
L. Malaszewski

The design and performance of a new instrument, based on improved Penning ion guns [1] for etching and coating samples for SEM and LM in a single vacuum chamber, are described. The instrument is based on an existing high resolution ion beam coating system, which is capable of producing high quality ultra-thin and amorphous conductive films, required for present high resolution electron microscopes. [2]. The fact that in this system both etching and coating processes are combined in one chamber, the specimen handling and specimen contamination are minimized. Furthermore, the system eliminates the traditional multiple mounting /dismounting of samples to various holders for mechanical polishing, etching, coating and microscopy purposes. The specimen can stay with the same holder throughout the entire process, increasing the sample through-put. Moreover, the system offers an alternative method to the traditional “wet chemical etching,” technique with its well known problems.


1989 ◽  
Vol 153 ◽  
Author(s):  
William Krakow

AbstractSeveral examples will be given of high resolution electron microscope images of both grain boundaries and interfaces and the methods which have been applied to understanding their atomic structure. Specific expitaxial interfacial structures considered are: Pd2Si/Si used for ohmic contacts, Al on Si overlayers and CaF2/Si where the CaF2, is an attractive possibility as a dielectric material. For the case of grain boundaries specific examples of both twist and tilt boundaries in Au will be given to show the imaging capability with the new generation of medium voltage electron microscopes.


Sign in / Sign up

Export Citation Format

Share Document