QUANTITATIVE YOUNG’S MODULUS MICROSCOPY BY ISOLATED LANGASITE OSCILLATOR: A CONTACT MECHANICS STUDY

2009 ◽  
Author(s):  
H. Ogi ◽  
T. Inoue ◽  
H. Nagai ◽  
M. Hirao ◽  
Donald O. Thompson ◽  
...  
2008 ◽  
Vol 79 (5) ◽  
pp. 053701 ◽  
Author(s):  
H. Ogi ◽  
T. Inoue ◽  
H. Nagai ◽  
M. Hirao

2018 ◽  
Vol 18 (07) ◽  
pp. 1840013 ◽  
Author(s):  
KEHAO WANG ◽  
DEMETRIOS T. VENETSANOS ◽  
JIAN WANG ◽  
BARBARA K. PIERSCIONEK

The objective of this study is to explore the feasibility of a compression test for measuring mechanical properties of intact eye lenses using novel parallel plate compression equipment to compare the accuracy of implementing a classical Hertzian model and a newly proposed adjusted Hertzian model to calculate Young’s modulus from compression test results using finite element (FE) analysis. Parallel-plate compression tests were performed on porcine lenses. An axisymmetric FE model was developed to simulate the experimental process to evaluate the accuracy of using the classical Hertzian theory of contact mechanics as well as a newly proposed adjusted Hertzian theory model for calculating the equivalent Young’s modulus. By fitting the force-displacement relation obtained from FE simulations to both the classical and adjusted Hertzian theory model and comparing the calculated modulus to the input modulus of the FE model, the results demonstrated that the classical Hertzian theory model overestimated the Young’s modulus with a proportional error of over 10%. The adjusted Hertzian theory model produced results that are closer to original input values with error ratios all lower than 1.29%. Measurements of three porcine lenses from the parallel plate compression experiments were analyzed with resulting values of Young’s modulus of between 3.2[Formula: see text]kPa and 4.3[Formula: see text]kPa calculated. This study demonstrates that the adjusted Hertzian theory of contact mechanics can be applied in conjunction with the parallel-plate compression system to investigate the overall mechanical behavior of intact lenses.


2019 ◽  
Vol 107 (2) ◽  
pp. 207 ◽  
Author(s):  
Jaroslav Čech ◽  
Petr Haušild ◽  
Miroslav Karlík ◽  
Veronika Kadlecová ◽  
Jiří Čapek ◽  
...  

FeAl20Si20 (wt.%) powders prepared by mechanical alloying from different initial feedstock materials (Fe, Al, Si, FeAl27) were investigated in this study. Scanning electron microscopy, X-ray diffraction and nanoindentation techniques were used to analyze microstructure, phase composition and mechanical properties (hardness and Young’s modulus). Finite element model was developed to account for the decrease in measured values of mechanical properties of powder particles with increasing penetration depth caused by surrounding soft resin used for embedding powder particles. Progressive homogenization of the powders’ microstructure and an increase of hardness and Young’s modulus with milling time were observed and the time for complete homogenization was estimated.


1981 ◽  
Vol 6 ◽  
Author(s):  
J.R. Mclaren ◽  
R.W. Davidge ◽  
I. Titchell ◽  
K. Sincock ◽  
A. Bromley

ABSTRACTHeating to temperatures up to 500°C, gives a reduction in Young's modulus and increase in permeability of granitic rocks and it is likely that a major reason is grain boundary cracking. The cracking of grain boundary facets in polycrystalline multiphase materials showing anisotropic thermal expansion behaviour is controlled by several microstructural factors in addition to the intrinsic thermal and elastic properties. Of specific interest are the relative orientations of the two grains meeting at the facet, and the size of the facet; these factors thus introduce two statistical aspects to the problem and these are introduced to give quantitative data on crack density versus temperature. The theory is compared with experimental measurements of Young's modulus and permeability for various rocks as a function of temperature. There is good qualitative agreement, and the additional (mainly microstructural) data required for a quantitative comparison are defined.


2020 ◽  
Vol 12 ◽  
Author(s):  
S.V. Kontomaris ◽  
A. Malamou ◽  
A. Stylianou

Background: The determination of the mechanical properties of biological samples using Atomic Force Microscopy (AFM) at the nanoscale is usually performed using basic models arising from the contact mechanics theory. In particular, the Hertz model is the most frequently used theoretical tool for data processing. However, the Hertz model requires several assumptions such as homogeneous and isotropic samples and indenters with perfectly spherical or conical shapes. As it is widely known, none of these requirements are 100 % fulfilled for the case of indentation experiments at the nanoscale. As a result, significant errors arise in the Young’s modulus calculation. At the same time, an analytical model that could account complexities of soft biomaterials, such as nonlinear behavior, anisotropy, and heterogeneity, may be far-reaching. In addition, this hypothetical model would be ‘too difficult’ to be applied in real clinical activities since it would require very heavy workload and highly specialized personnel. Objective: In this paper a simple solution is provided to the aforementioned dead-end. A new approach is introduced in order to provide a simple and accurate method for the mechanical characterization at the nanoscale. Method: The ratio of the work done by the indenter on the sample of interest to the work done by the indenter on a reference sample is introduced as a new physical quantity that does not require homogeneous, isotropic samples or perfect indenters. Results: The proposed approach, not only provides an accurate solution from a physical perspective but also a simpler solution which does not require activities such as the determination of the cantilever’s spring constant and the dimensions of the AFM tip. Conclusion: The proposed, by this opinion paper, solution aims to provide a significant opportunity to overcome the existing limitations provided by Hertzian mechanics and apply AFM techniques in real clinical activities.


2011 ◽  
Vol 695 ◽  
pp. 170-173 ◽  
Author(s):  
Voravadee Suchaiya ◽  
Duangdao Aht-Ong

This work focused on the preparation of the biocomposite films of polylactic acid (PLA) reinforced with microcrystalline cellulose (MCC) prepared from agricultural waste, banana stem fiber, and commercial microcrystalline cellulose, Avicel PH 101. Banana stem microcrystalline cellulose (BS MCC) was prepared by three steps, delignification, bleaching, and acid hydrolysis. PLA and two types of MCC were processed using twin screw extruder and fabricated into film by a compression molding. The mechanical and crystalline behaviors of the biocomopsite films were investigated as a function of type and amount of MCC. The tensile strength and Young’s modulus of PLA composites were increased when concentration of MCC increased. Particularly, banana stem (BS MCC) can enhance tensile strength and Young’s modulus of PLA composites than the commercial MCC (Avicel PH 101) because BS MCC had better dispersion in PLA matrix than Avicel PH 101. This result was confirmed by SEM image of fractured surface of PLA composites. In addition, XRD patterns of BS MCC/PLA composites exhibited higher crystalline peak than that of Avicel PH 101/PLA composites


Sign in / Sign up

Export Citation Format

Share Document