MHD-Oscillation Modes of a Flaring Loop Using Microwave Observations With High Spatial Resolution

2006 ◽  
Author(s):  
Veronika E. Reznikova
2020 ◽  
Vol 10 (7) ◽  
pp. 2237 ◽  
Author(s):  
Serena Artese ◽  
Giovanni Nico

This article presents a methodology for the monitoring of tall structures based on the joint use of a terrestrial laser scanner (TLS), configured in line scanner mode, and a ground-based real aperture radar (GB-RAR) interferometer. The methodology provides both natural frequencies and oscillation amplitudes of tall structures. Acquisitions of the surface of the tall structure are performed by the TLS with a high sampling rate: each line scan provides an instantaneous longitudinal section. By interpolating the points of each line, oscillation profiles are estimated with a much better precision than each single point. The amplitude and frequency of the main oscillation mode of the whole structure are derived from the TLS profiles. GB-RAR measurements are used to measure the vibration frequencies of higher oscillation modes which are not caught by the TLS due its lower precision in the measurement of displacements. In contrast, the high spatial resolution of TLS measurements provides an accurate description of oscillation amplitude along the tower, which cannot be caught by the GB-RAR, due to its poorer spatial resolution. TLS and GB-RAR acquisitions are simultaneous. The comparison with the analytical solution for oscillation modes demonstrates that the proposed methodology can provide useful information for structural health monitoring (SHM). The methodology does not require the use of targets on the structure and it can be applied during its normal use, even in presence of dynamic loads (wind, traffic vibrations, etc.). A test was carried out on a wind tower where the synergistic use of TLS and GB-RAR made it possible to fully describe the spectral properties of the tower and at the same time measure the amplitude of the first oscillation mode along the tower with a high spatial resolution.


Author(s):  
K. Przybylski ◽  
A. J. Garratt-Reed ◽  
G. J. Yurek

The addition of so-called “reactive” elements such as yttrium to alloys is known to enhance the protective nature of Cr2O3 or Al2O3 scales. However, the mechanism by which this enhancement is achieved remains unclear. An A.E.M. study has been performed of scales grown at 1000°C for 25 hr. in pure O2 on Co-45%Cr implanted at 70 keV with 2x1016 atoms/cm2 of yttrium. In the unoxidized alloys it was calculated that the maximum concentration of Y was 13.9 wt% at a depth of about 17 nm. SIMS results showed that in the scale the yttrium remained near the outer surface.


Author(s):  
E. G. Rightor

Core edge spectroscopy methods are versatile tools for investigating a wide variety of materials. They can be used to probe the electronic states of materials in bulk solids, on surfaces, or in the gas phase. This family of methods involves promoting an inner shell (core) electron to an excited state and recording either the primary excitation or secondary decay of the excited state. The techniques are complimentary and have different strengths and limitations for studying challenging aspects of materials. The need to identify components in polymers or polymer blends at high spatial resolution has driven development, application, and integration of results from several of these methods.


Author(s):  
Kosuke Nomura ◽  
Ryutaro Oi ◽  
Takanori Senoh ◽  
Taiichiro Kurita ◽  
Takayuki Hamamoto

Sign in / Sign up

Export Citation Format

Share Document