Erratum: “Magnetic nanowire based high resolution magnetic force microscope probes” [Appl. Phys. Lett. 87, 123507 (2005)]

2005 ◽  
Vol 87 (22) ◽  
pp. 229901
Author(s):  
G. Yang ◽  
J. Tang ◽  
S. Kato ◽  
Q. Zhang ◽  
L. C. Qin ◽  
...  
2005 ◽  
Vol 87 (12) ◽  
pp. 123507 ◽  
Author(s):  
G. Yang ◽  
J. Tang ◽  
S. Kato ◽  
Q. Zhang ◽  
L. C. Qin ◽  
...  

2013 ◽  
Vol 543 ◽  
pp. 35-38 ◽  
Author(s):  
Masaaki Futamoto ◽  
Tatsuya Hagami ◽  
Shinji Ishihara ◽  
Kazuki Soneta ◽  
Mitsuru Ohtake

Effects of magnetic material, coating thickness, and tip radius on magnetic force microscope (MFM) spatial resolution have been systematically investigated. MFM tips are prepared by using an UHV sputtering system by coating magnetic materials on non-magnetic Si tips employing targets of Ni, Ni-Fe, Co, Fe, Fe-B, and Fe-Pd. MFM spatial resolutions better than 9 nm have been confirmed by employing magnetic tips coated with high magnetic moment materials with optimized thicknesses.


2013 ◽  
Vol 40 ◽  
pp. 01002 ◽  
Author(s):  
Tatsuya Hagami ◽  
Kazuki Soneta ◽  
Mitsuru Ohtake ◽  
Masaaki Futamoto

Author(s):  
P. Kappenberger ◽  
H.J. Hug ◽  
S. Martin ◽  
H.-J. Guntherodt ◽  
D. Buchel ◽  
...  

1998 ◽  
Vol 37 (Part 2, No. 11A) ◽  
pp. L1343-L1345 ◽  
Author(s):  
Hitoshi Suzuki ◽  
Tsuyoshi Tanaka ◽  
Tomohito Sasaki ◽  
Noriyuki Nakamura ◽  
Tadashi Matsunaga ◽  
...  

2001 ◽  
Vol 7 (S2) ◽  
pp. 866-867
Author(s):  
K. Suzuki ◽  
S. Kitamura ◽  
C. B. Mooney

In recent years, the magnetic force microscope (MFM) has been used not only for the evaluation of magnetic media but also for the measurement of magnetic characteristics of quantum dots as well as in various fields, because the MFM can visualize magnetic field on the sample surface with the high resolution. The MFM observation in ultra-high vacuum (UHV) requires to reduce the adsorption layer on the sample surface for high resolution observation. The slope detection mode using the variation of vibrating cantilever is basically unstable in UHV due to the increase in the Q factor of the cantilever. Accordingly it has been used for the MFM observation in air. On the other hand, the FM detection technique offers a very high sensitivity because of the high Q factor.This repot describes the MFM technique to take a magnetic image steadily in UHV. We observed the surface of a magnetic material with MFM technique in UHV, and compared the slope detection technique, the phase detection technique using phase variation of cantilever vibration, and the FM detection technique.


2012 ◽  
Vol 48 (11) ◽  
pp. 3673-3676 ◽  
Author(s):  
Xiaoxi Liu ◽  
Shinsaku Isomura ◽  
Akimitsu Morisako

Sign in / Sign up

Export Citation Format

Share Document