Study on the strength and elongation of free-standing Al beams for microelectromechanical systems applications

2004 ◽  
Vol 84 (6) ◽  
pp. 915-917 ◽  
Author(s):  
Hoo-Jeong Lee ◽  
Ping Zhang ◽  
John C. Bravman
Microscopy ◽  
2020 ◽  
Vol 69 (1) ◽  
pp. 11-16
Author(s):  
Takaharu Nagatomi ◽  
Tatsuya Nakao ◽  
Yoko Fujimoto

Abstract In the present study, a free-standing object-sampling technique for microelectromechanical systems (MEMS) is developed to measure their sidewall surface roughnesses by atomic force microscopy (AFM). For this purpose, a conventional focused ion beam (FIB) sampling technique widely used for cross-sectional transmission electron microscope specimen preparation was applied. The sub-nm-order roughness parameters were quantitatively measured for sidewalls of Si-bridge test samples. The roughness parameters were compared before and after H2 annealing treatment, which induced smoothing of the surface by migration of the Si atoms. The reduction in the surface roughness by a factor of approximately one-third with 60-s H2 annealing was quantitatively evaluated by AFM. The present study confirms that the developed FIB–AFM technique is one potential approach for quantitatively evaluating the surface-roughness parameters on the oblique faces of free-standing objects in MEMS devices.


Actuators ◽  
2018 ◽  
Vol 7 (3) ◽  
pp. 38 ◽  
Author(s):  
Marija Cauchi ◽  
Ivan Grech ◽  
Bertram Mallia ◽  
Pierluigi Mollicone ◽  
Nicholas Sammut

The ongoing development of microelectromechanical systems (MEMS) over the past decades has made possible the achievement of high-precision micromanipulation within the micromanufacturing, microassembly and biomedical fields. This paper presents different design variants of a horizontal electrothermally actuated MEMS microgripper that are developed as microsystems to micromanipulate and study the deformability properties of human red blood cells (RBCs). The presented microgripper design variants are all based on the U-shape `hot and cold arm’ actuator configuration, and are fabricated using the commercially available Multi-User MEMS Processes (MUMPs®) that are produced by MEMSCAP, Inc. (Durham, NC, USA) and that include both surface micromachined (PolyMUMPs™) and silicon-on-insulator (SOIMUMPs™) MEMS fabrication technologies. The studied microgripper design variants have the same in-plane geometry, with their main differences arising from the thickness of the fabricated structures, the consequent air gap separation between the structure and the substrate surface, as well as the intrinsic nature of the silicon material used. These factors are all inherent characteristics of the specific fabrication technologies used. PolyMUMPs™ utilises polycrystalline silicon structures that are composed of two free-standing, independently stackable structural layers, enabling the user to achieve structure thicknesses of 1.5 μm, 2 μm and 3.5 μm, respectively, whereas SOIMUMPs™ utilises a 25 μm thick single crystal silicon structure having only one free-standing structural layer. The microgripper design variants are presented and compared in this work to investigate the effect of their differences on the temperature distribution and the achieved end-effector displacement. These design variants were analytically studied, as well as numerically modelled using finite element analysis where coupled electrothermomechanical simulations were carried out in CoventorWare® (Version 10, Coventor, Inc., Cary, NC, USA). Experimental results for the microgrippers’ actuation under atmospheric pressure were obtained via optical microscopy studies for the PolyMUMPs™ structures, and they were found to be conforming with the predictions of the analytical and numerical models. The focus of this work is to identify which one of the studied design variants best optimises the microgripper’s electrothermomechanical performance in terms of a sufficient lateral tip displacement, minimum out-of-plane displacement at the arm tips and good heat transfer to limit the temperature at the cell gripping zone, as required for the deformability study of RBCs.


Sensors ◽  
2020 ◽  
Vol 20 (5) ◽  
pp. 1245
Author(s):  
Alberto Espinoza ◽  
Fabio Alves ◽  
Renato Rabelo ◽  
German Da Re ◽  
Gamani Karunasiri

In this work, microelectromechanical systems (MEMS)-based directional acoustic sensors operating in an underwater environment are explored. The studied sensors consist of a free-standing single wing or two wings pivoted to a substrate. The sensors operate in a narrow frequency band determined by the resonant frequency of the mechanical structure. The electronic readout of the mechanical response is obtained using interdigitated comb finger capacitors attached to the wings. The characteristics of MEMS sensors immersed in silicone oil are simulated using finite element modeling. The performance of the sensors is evaluated both in air and underwater. For underwater testing and operation, the sensors are packaged in a housing containing silicone oil, which was specially developed to present near unity acoustic transmission. The measurements show that the resonant frequency of the sensors obtained in air shifts to a lower frequency when immersed in silicone oil, which is primarily due to the mass loading of the liquid. The peak sensitivity of the MEMS sensors is approximately 6 mV/Pa or −165 dB re 1 V/μPa, and the directional response shows a dipole pattern. The signal-to-noise ratio was found to be about 200 or 23 dB at 1 Pa incident sound pressure. The results show the potential of MEMS sensors to be used in underwater applications for sound source localization.


2000 ◽  
Vol 76 (23) ◽  
pp. 3415-3417 ◽  
Author(s):  
Hoo-Jeong Lee ◽  
Guido Cornella ◽  
John C. Bravman

1996 ◽  
Vol 444 ◽  
Author(s):  
Hyeon-Seag Kim ◽  
D. L. Polla ◽  
S. A. Campbell

AbstractThe electrical reliability properties of PZT (54/46) thin films have been measured for the purpose of integrating this material with silicon-based microelectromechanical systems. Ferroelectric thin films of PZT were prepared by metal organic decomposition. The charge trapping and degradation properties of these thin films were studied through device characteristics such as hysteresis loop, leakage current, fatigue, dielectric constant, capacitancevoltage, and loss factor measurements. Several unique experimental results have been found. Different degradation processes were verified through fatigue (bipolar stress), low and high charge injection (unipolar stress), and high field stressing (unipolar stress).


Author(s):  
Paulina Hebisz ◽  
Rafal Hebisz ◽  
Marek Zaton

AbstractBackground: The purpose of this study was to compare body balance in road and off-road cyclists, immediately before and after the racing season.Material/Methods: Twenty individuals participated in the study and they were divided into two groups: specialists in road-cycling (n = 10) and in off-road cycling (n = 10). Immediately before and after the five-month racing season stabilographic trials were carried out (at rest and after progressive exercise). In assessing body balance the distance and velocity of the centre shifts (in the anterior-posterior and left-right direction) were analysed. The tests were performed with the cyclists’ eyes open, eyes closed, and in feedback.Results: After the racing season, in the off-road cyclists’ group, distance and velocity of the centre of pressure shifts increased after a progressive exercise.Conclusions: In the off-road cyclists’ group the balance of the body in the sagittal plane deteriorated after the racing season. Moreover, after the racing season off-road cyclists were characterized by a worse balance of the body, compared to road cyclists


2020 ◽  
Author(s):  
Michelina Soccio ◽  
Nadia Lotti ◽  
Andrea Munari ◽  
Esther Rebollar ◽  
Daniel E Martínez-Tong

<p>Nanostructured wrinkles were developed on fully bio-based poly(trimethylene furanoate) (PTF) films by using the technique of Laser Induced Periodic Surface Structures (LIPSS). We investigated the effect of irradiation time on wrinkle formation using an UV pulsed laser source, at a fluence of 8 mJ/cm2. It was found that the pulse range between 600 and 4800 pulses allowed formation of periodic nanometric ripples. The nanostructured surface was studied using a combined macro- and nanoscale approach. We evaluated possible physicochemical changes taking place on the polymer surface after irradiation by infrared spectroscopy, contact angle measurements and atomic force microscopy. The macroscopic physicochemical properties of PTF showed almost no changes after nanostructure formation, differently from the results previously found for the terephthalic counterparts, as poly(ethyleneterephthalate), PET, and poly(trimethyleneterephthalate), PTT. The surface mechanical properties of the nanostructured PTF were found to be improved, as evidenced by nanomechanical force spectroscopy measurements. In particular, an increased Young’s modulus and higher stiffness for the nanostructured sample were measured. <br></p>


Sign in / Sign up

Export Citation Format

Share Document