Development and operation of a thin foil Faraday collector as a lost ion diagnostic for high yield d-t tokamak fusion plasmas

1999 ◽  
Vol 70 (1) ◽  
pp. 1149-1153 ◽  
Author(s):  
F. E. Cecil ◽  
B. Roy ◽  
S. Kern ◽  
A. Nowak ◽  
Y. Takimoto ◽  
...  
Keyword(s):  
1997 ◽  
Vol 68 (1) ◽  
pp. 361-364 ◽  
Author(s):  
M. J. Loughlin ◽  
F. E. Cecil ◽  
M. Hone ◽  
O. N. Jarvis ◽  
S. S. Medley ◽  
...  

Author(s):  
QianQian Han ◽  
Xuesong Geng ◽  
Baifei Shen ◽  
Liangliang Ji ◽  
Zhizhan Xu

Abstract With the forthcoming 10-100PW laser facilities, laser-driven electron-positron-pair production has gained particular interest. Here a scheme to enhance the generation of dense electron-positron-pairs is proposed and numerically demonstrated, employing double laser pulses at the intensity level of 10^23 W cm^(-2). The first laser accelerates a thin foil to a relativistic speed via the radiation-pressure-acceleration mechanism and a counter-propagating laser irradiates this flying plasma layer. The simulation results indicate that a high-yield and well-collimated positron beam (~5.5×10^10 positrons/pulse, 8.8nC/pulse) is generated with a large peak density(1.1×10^21 cm^(-3) ) by using tens-of-PW laser pulses.


Author(s):  
T. Mukai ◽  
T. E. Mitchell

Radiation-induced homogeneous precipitation in Ni-Be alloys was recently observed by high voltage electron microscopy. A coupling of interstitial flux with solute Be atoms is responsible for the precipitation. The present investigation further shows that precipitation is also induced at thin foil surfaces by electron irradiation under a high vacuum.


Author(s):  
F. I. Grace ◽  
L. E. Murr

During the course of electron transmission investigations of the deformation structures associated with shock-loaded thin foil specimens of 70/30 brass, it was observed that in a number of instances preferential etching occurred along grain boundaries; and that the degree of etching appeared to depend upon the various experimental conditions prevailing during electropolishing. These included the electrolyte composition, the average current density, and the temperature in the vicinity of the specimen. In the specific case of 70/30 brass shock-loaded at pressures in the range 200-400 kilobars, the predominant mode of deformation was observed to be twin-type faults which in several cases exhibited preferential etching similar to that observed along grain boundaries. A novel feature of this particular phenomenon was that in certain cases, especially for twins located in the vicinity of the specimen edge, the etching or preferential electropolishing literally isolated these structures from the matrix.


Author(s):  
E. A. Kenik ◽  
J. Bentley

Cliff and Lorimer (1) have proposed a simple approach to thin foil x-ray analy sis based on the ratio of x-ray peak intensities. However, there are several experimental pitfalls which must be recognized in obtaining the desired x-ray intensities. Undesirable x-ray induced fluorescence of the specimen can result from various mechanisms and leads to x-ray intensities not characteristic of electron excitation and further results in incorrect intensity ratios.In measuring the x-ray intensity ratio for NiAl as a function of foil thickness, Zaluzec and Fraser (2) found the ratio was not constant for thicknesses where absorption could be neglected. They demonstrated that this effect originated from x-ray induced fluorescence by blocking the beam with lead foil. The primary x-rays arise in the illumination system and result in varying intensity ratios and a finite x-ray spectrum even when the specimen is not intercepting the electron beam, an ‘in-hole’ spectrum. We have developed a second technique for detecting x-ray induced fluorescence based on the magnitude of the ‘in-hole’ spectrum with different filament emission currents and condenser apertures.


Author(s):  
N. J. Zaluzec

The ultimate sensitivity of microchemical analysis using x-ray emission rests in selecting those experimental conditions which will maximize the measured peak-to-background (P/B) ratio. This paper presents the results of calculations aimed at determining the influence of incident beam energy, detector/specimen geometry and specimen composition on the P/B ratio for ideally thin samples (i.e., the effects of scattering and absorption are considered negligible). As such it is assumed that the complications resulting from system peaks, bremsstrahlung fluorescence, electron tails and specimen contamination have been eliminated and that one needs only to consider the physics of the generation/emission process.The number of characteristic x-ray photons (Ip) emitted from a thin foil of thickness dt into the solid angle dΩ is given by the well-known equation


Author(s):  
R.W. Carpenter

Interest in precipitation processes in silicon appears to be centered on transition metals (for intrinsic and extrinsic gettering), and oxygen and carbon in thermally aged materials, and on oxygen, carbon, and nitrogen in ion implanted materials to form buried dielectric layers. A steadily increasing number of applications of microanalysis to these problems are appearing. but still far less than the number of imaging/diffraction investigations. Microanalysis applications appear to be paced by instrumentation development. The precipitation reaction products are small and the presence of carbon is often an important consideration. Small high current probes are important and cryogenic specimen holders are required for consistent suppression of contamination buildup on specimen areas of interest. Focussed probes useful for microanalysis should be in the range of 0.1 to 1nA, and estimates of spatial resolution to be expected for thin foil specimens can be made from the curves shown in Fig. 1.


Author(s):  
N. Tempel ◽  
M. C. Ledbetter

Carbon films have been a support of choice for high resolution electron microscopy since the introduction of vacuum evaporation of carbon. The desirable qualities of carbon films and methods of producing them has been extensively reviewed. It is difficult to get a high yield of grids by many of these methods, especially if virtually all of the windows must be covered with a tightly bonded, quality film of predictable thickness. We report here a method for producing carbon foils designed to maximize these attributes: 1) coverage of virtually all grid windows, 2) freedom from holes, wrinkles or folds, 3) good adhesion between film and grid, 4) uniformity of film and low noise structure, 5) predictability of film thickness, and 6) reproducibility.Our method utilizes vacuum evaporation of carbon from a fiber onto celloidin film and grid bars, adhesion of the film complex to the grid by carbon-carbon contact, and removal of the celloidin by acetone dissolution. Materials must be of high purity, and cleanliness must be rigorously maintained.


Author(s):  
Prakash Rao

Image shifts in out-of-focus dark field images have been used in the past to determine, for example, epitaxial relationships in thin films. A recent extension of the use of dark field image shifts has been to out-of-focus images in conjunction with stereoviewing to produce an artificial stereo image effect. The technique, called through-focus dark field electron microscopy or 2-1/2D microscopy, basically involves obtaining two beam-tilted dark field images such that one is slightly over-focus and the other slightly under-focus, followed by examination of the two images through a conventional stereoviewer. The elevation differences so produced are usually unrelated to object positions in the thin foil and no specimen tilting is required.In order to produce this artificial stereo effect for the purpose of phase separation and identification, it is first necessary to select a region of the diffraction pattern containing more than just one discrete spot, with the objective aperture.


Sign in / Sign up

Export Citation Format

Share Document