scholarly journals Ischaemic Sciatic Neuropathy: an Important Complication of Embolisation of a Type II Endoleak

2002 ◽  
Vol 24 (5) ◽  
pp. 462-463 ◽  
Author(s):  
N.D. Forester ◽  
D. Parry ◽  
D. Kessel ◽  
I. Robertson ◽  
J. Patel ◽  
...  
2020 ◽  
Vol 4 ◽  
pp. 9
Author(s):  
Salman Mirza ◽  
Shahnawaz Ansari

We present a case of a 72-year-old male with an abdominal aortic aneurysm status post-endovascular aneurysm repair (EVAR). Follow-up imaging demonstrated an enlarging type II endoleak and attempts at transarterial coil embolization of the inferior mesenteric artery were unsuccessful. The patient underwent image-guided percutaneous translumbar type II endoleak repair using XperGuide (Philips, Andover, MA USA).


2021 ◽  
Vol 73 (6) ◽  
pp. 2206
Author(s):  
A. Mathlouthi ◽  
I. Guajardo ◽  
O. Al-Nouri ◽  
M. Malas ◽  
Barleben

Vascular ◽  
2021 ◽  
pp. 170853812199657
Author(s):  
Tiehao Wang ◽  
Jichun Zhao ◽  
Ding Yuan

Objectives Multiple organ failure is a rare manifestation of ilio-iliac arteriovenous fistula which can lead to a high rate of misdiagnosis and death. Methods We reported a 61-year-old man presenting with multiple organ failure rapidly after right lower limb swelling. Computed tomography angiography showed an ilio-iliac arteriovenous fistula caused by right common iliac artery aneurysm, and venous thrombosis of bilateral common iliac veins. A bifurcated stent-graft with coil embolization of right internal iliac artery was used for repair. Results The patient recovered rapidly and was discharged without complications. Although arteriovenous fistula persisted due to type II endoleak, aneurysm sac and inferior vena cava significantly shrunk at six months follow-up. Conclusions This report demonstrated that multiple organ failure may appear when the distal outflow tracts of arteriovenous fistula are obstructed. Moreover, endovascular repair is effective for reversal of multiple organ failure caused by arteriovenous fistula, even if arteriovenous fistula persists due to type II endoleak.


2002 ◽  
Vol 9 (1) ◽  
pp. 90-97 ◽  
Author(s):  
Francesco Serino ◽  
Damiano Abeni ◽  
Elisabetta Galvagni ◽  
Savino G. Sardella ◽  
Alberto Scuro ◽  
...  

Purpose: To test the hypothesis that D-dimer (D-D), a cross-linked fibrin degradation product of an ongoing thrombotic event, could be a marker for incomplete aneurysm exclusion after endovascular abdominal aortic aneurysm (AAA) repair. Methods: In a multicenter study, 83 venous blood samples were collected from 74 AAA endograft patients and controls. Twenty subjects who were >6 months postimplantation and had evidence of an endoleak and/or an unmodified or increasing AAA sac diameter formed the test group. Controls were 10 nondiseased subjects >65 years old, 18 AAA surgical candidates, and 26 postoperative endograft patients with no endoleak and a shrinking aneurysm. Blood samples were analyzed for D-D through a latex turbidimetric immunoassay. The endograft patients were stratified into 5 clinical groups for analysis: no endoleak and decreasing sac diameter, no endoleak and increasing/unchanged sac diameter, type II endoleak and decreasing sac diameter, type II endoleak and increasing/unchanged sac diameter, and type I endoleak. Results: Individual D-D values were highly variable, but differences among clinical groups were statistically significant (p < 0.0001). D-D values did not vary significantly between patients with stable, untreated AAAs and age-matched controls (238 ± 180 ng/mL versus 421 ± 400 ng/mL, p > 0.05). Median D-D values increased at 4 days postoperatively (963 ng/mL versus 382 ng/mL, p > 0.05) and did not vary thereafter if there was no endoleak and the aneurysm sac decreased. D-D mean values were higher in patients with type I endoleak (1931 ± 924 ng/mL, p < 0.005) and those with unchanged/increasing sac diameters (1272 ± 728 ng/mL) than in cases with decreasing diameters (median 638 ± 238 ng/mL) despite the presence of endoleak (p < 0.0005). Conclusions: Elevated D-D may prove to be a useful marker for fixation problems after endovascular AAA repair and may help rule out type I endoleak, thus excluding patients from unnecessary invasive tests.


2011 ◽  
Vol 22 (2) ◽  
pp. 163-167 ◽  
Author(s):  
Marc A. Bailey ◽  
Simon J. McPherson ◽  
Max A. Troxler ◽  
A. Howard S. Peach ◽  
Jai V. Patel ◽  
...  

2012 ◽  
Vol 26 (6) ◽  
pp. 860.e1-860.e7 ◽  
Author(s):  
Christos V. Ioannou ◽  
Dimitrios K. Tsetis ◽  
Dimitrios G. Kardoulas ◽  
Pavlos G. Katonis ◽  
Asterios N. Katsamouris

2003 ◽  
Vol 10 (3) ◽  
pp. 424-432 ◽  
Author(s):  
Chuh K. Chong ◽  
Thien V. How ◽  
Geoffrey L. Gilling-Smith ◽  
Peter L. Harris

Purpose: To investigate the effect on intrasac pressure of stent-graft deployment within a life-size silicone rubber model of an abdominal aortic aneurysm (AAA) maintained under physiological conditions of pressure and flow. Methods: A commercial bifurcated device with the polyester fabric preclotted with gelatin was deployed in the AAA model. A pump system generated physiological flow. Mean and pulse aortic and intrasac pressures were measured simultaneously using pressure transducers. To simulate a type I endoleak, plastic tubing was placed between the aortic wall and the stent-graft at the proximal anchoring site. Type II endoleak was simulated by means of side branches with set inflow and outflow pressures and perfusion rates. Type IV endoleak was replicated by removal of gelatin from the graft fabric. Results: With no endoleak, the coated graft reduced the mean and pulse sac pressures to negligible values. When a type I endoleak was present, mean sac pressure reached a value similar to mean aortic pressure. When net flow through the sac due to a type II endoleak was present, mean sac pressure was a function of the inlet pressure, while pulse pressure in the sac was dependent on both inlet and outlet pressures. As perfusion rates increased, both mean and pulse sac pressures decreased. When there was no outflow, mean sac pressure was similar to mean aortic pressure. In the presence of both type I and type II endoleaks, mean sac pressure reached mean aortic pressure when the net perfusion rate was low. Conclusions: In vitro studies are useful in gaining an understanding of the impact of different types of endoleaks, in isolation and in combination, on intrasac pressure after aortic stent-graft deployment.


Sign in / Sign up

Export Citation Format

Share Document