scholarly journals Poly(ethyleneglycol) in electrospray ionization (ESI) mass spectrometry

Analusis ◽  
2000 ◽  
Vol 28 (4) ◽  
pp. 263-268 ◽  
Author(s):  
S. Varray ◽  
J.-L. Aubagnac ◽  
F. Lamaty ◽  
R. Lazaro ◽  
J. Martinez ◽  
...  
The Analyst ◽  
2020 ◽  
Vol 145 (20) ◽  
pp. 6625-6631
Author(s):  
Rongkun Lin ◽  
Qiao Lu ◽  
Zheng Lin ◽  
Wei Hang ◽  
Benli Huang

We present a strategy for the coupling of laser-induced acoustic desorption (LIAD) with electrospray ionization (ESI) mass spectrometry.


Molecules ◽  
2018 ◽  
Vol 23 (12) ◽  
pp. 3366
Author(s):  
Mohamed Abdi Bellau ◽  
Olga Bortolini ◽  
Giancarlo Fantin ◽  
Marco Fogagnolo ◽  
Daniele Ragno ◽  
...  

The binding properties of quercetin toward chloride anions were investigated by means of 1H-NMR, 13C-NMR, and electrospray ionization mass spectrometry (ESI-MS) measurements, as well as computational calculations. The results indicate that quercetin behaves primarily as a ditopic receptor with the binding site of the B ring that exhibits stronger chloride affinity compared to the A ring. However, these sites are stronger receptors than those of catechol and resorcinol because of their conjugation with the carbonyl group located on the C ring. The 1:1 and 1:2 complexation of this flavonoid with Cl− was also supported by ESI mass spectrometry.


2020 ◽  
Vol 32 (2) ◽  
pp. 128-133
Author(s):  
Andreea Silvia Neamţu ◽  
Andrei Biţă ◽  
Ion Romulus Scorei ◽  
Gabriela Rău ◽  
Ludovic Everard Bejenaru ◽  
...  

The identification and quantitation of nicotinamide riboside (NAR) and its main related compound (nicotinamide) were achieved using high-performance thin-layer chromatography (HPTLC)–ultraviolet (UV) densitometry with confirmation by online electrospray ionization (ESI)–mass spectrometry (MS). As the stationary phase, HPTLC Si 60 F254 glass plates were employed; the mobile phase was ethanol–1 M ammonium acetate–formic acid (7:1:0.1, v/v/v). No derivatization was applied, and UV densitometry was performed in the absorbance mode (270 nm). The method was validated by specificity, linearity, accuracy, precision, and robustness.


2016 ◽  
Vol 18 (36) ◽  
pp. 25483-25490 ◽  
Author(s):  
Satrajit Chakrabarty ◽  
Evan R. Williams

The hydration of halide and iodate anions was investigated using electrospray ionization (ESI) mass spectrometry and infrared photodissociation (IRPD) spectroscopy.


RSC Advances ◽  
2015 ◽  
Vol 5 (114) ◽  
pp. 94315-94320 ◽  
Author(s):  
Anil Kumar Meher ◽  
Yu-Chie Chen

Tissue paper with fibrous structures is demonstrated to be the suitable sample loading substrate, sampling tool, and electrospray ionization (ESI) emitter for the analysis of analytes with a wide mass range in ESI mass spectrometry.