Image-based IoT measurement techniques in disease diagnosis

Author(s):  
S. Vijayalakshmi ◽  
Savita ◽  
Balamurugan Balusamy
1975 ◽  
Vol 26 ◽  
pp. 87-92
Author(s):  
P. L. Bender

AbstractFive important geodynamical quantities which are closely linked are: 1) motions of points on the Earth’s surface; 2)polar motion; 3) changes in UT1-UTC; 4) nutation; and 5) motion of the geocenter. For each of these we expect to achieve measurements in the near future which have an accuracy of 1 to 3 cm or 0.3 to 1 milliarcsec.From a metrological point of view, one can say simply: “Measure each quantity against whichever coordinate system you can make the most accurate measurements with respect to”. I believe that this statement should serve as a guiding principle for the recommendations of the colloquium. However, it also is important that the coordinate systems help to provide a clear separation between the different phenomena of interest, and correspond closely to the conceptual definitions in terms of which geophysicists think about the phenomena.In any discussion of angular motion in space, both a “body-fixed” system and a “space-fixed” system are used. Some relevant types of coordinate systems, reference directions, or reference points which have been considered are: 1) celestial systems based on optical star catalogs, distant galaxies, radio source catalogs, or the Moon and inner planets; 2) the Earth’s axis of rotation, which defines a line through the Earth as well as a celestial reference direction; 3) the geocenter; and 4) “quasi-Earth-fixed” coordinate systems.When a geophysicists discusses UT1 and polar motion, he usually is thinking of the angular motion of the main part of the mantle with respect to an inertial frame and to the direction of the spin axis. Since the velocities of relative motion in most of the mantle are expectd to be extremely small, even if “substantial” deep convection is occurring, the conceptual “quasi-Earth-fixed” reference frame seems well defined. Methods for realizing a close approximation to this frame fortunately exist. Hopefully, this colloquium will recommend procedures for establishing and maintaining such a system for use in geodynamics. Motion of points on the Earth’s surface and of the geocenter can be measured against such a system with the full accuracy of the new techniques.The situation with respect to celestial reference frames is different. The various measurement techniques give changes in the orientation of the Earth, relative to different systems, so that we would like to know the relative motions of the systems in order to compare the results. However, there does not appear to be a need for defining any new system. Subjective figures of merit for the various system dependon both the accuracy with which measurements can be made against them and the degree to which they can be related to inertial systems.The main coordinate system requirement related to the 5 geodynamic quantities discussed in this talk is thus for the establishment and maintenance of a “quasi-Earth-fixed” coordinate system which closely approximates the motion of the main part of the mantle. Changes in the orientation of this system with respect to the various celestial systems can be determined by both the new and the conventional techniques, provided that some knowledge of changes in the local vertical is available. Changes in the axis of rotation and in the geocenter with respect to this system also can be obtained, as well as measurements of nutation.


Author(s):  
T. Schober

Nb, Ta and V are prototype substances for the study of the endothermic reactions of H with metals. Such metal-hydrogen reactions have gained increased importance due to the application of metal-hydrides in hydrogen- und heat storage devices. Electron microscopy and diffraction were demonstrated to be excellent methods in the study of hydride morphologies and structures (1). - Figures 1 and 2 show the NbH and TaH phase diagrams (2,3,4). EM techniques have contributed substantially to the elucidation of the structures and domain configurations of phases β, ζ and ε (1,4). Precision length measurement techniques of distances in reciprocal space (5) recently led to a detailed understanding of the distortions of the unit cells of phases ζ and ε (4). In the same work (4) the existence of the new phase η was shown. It is stable near -68 °C. The sequence of transitions is thus below 70 %.


Author(s):  
Karen K. Baker ◽  
David L. Roberts

Plant disease diagnosis is most often accomplished by examination of symptoms and observation or isolation of causal organisms. Occasionally, diseases of unknown etiology occur and are difficult or impossible to accurately diagnose by the usual means. In 1980, such a disease was observed on Agrostis palustris Huds. c.v. Toronto (creeping bentgrass) putting greens at the Butler National Golf Course in Oak Brook, IL.The wilting symptoms of the disease and the irregular nature of its spread through affected areas suggested that an infectious agent was involved. However, normal isolation procedures did not yield any organism known to infect turf grass. TEM was employed in order to aid in the possible diagnosis of the disease.Crown, root and leaf tissue of both infected and symptomless plants were fixed in cold 5% glutaraldehyde in 0.1 M phosphate buffer, post-fixed in buffered 1% osmium tetroxide, dehydrated in ethanol and embedded in a 1:1 mixture of Spurrs and epon-araldite epoxy resins.


1999 ◽  
Vol 4 (1) ◽  
pp. 6-7
Author(s):  
James J. Mangraviti

Abstract The accurate measurement of hip motion is critical when one rates impairments of this joint, makes an initial diagnosis, assesses progression over time, and evaluates treatment outcome. The hip permits all motions typical of a ball-and-socket joint. The hip sacrifices some motion but gains stability and strength. Figures 52 to 54 in AMA Guides to the Evaluation of Permanent Impairment (AMA Guides), Fourth Edition, illustrate techniques for measuring hip flexion, loss of extension, abduction, adduction, and external and internal rotation. Figure 53 in the AMA Guides, Fourth Edition, illustrates neutral, abducted, and adducted positions of the hip and proper alignment of the goniometer arms, and Figure 52 illustrates use of a goniometer to measure flexion of the right hip. In terms of impairment rating, hip extension (at least any beyond neutral) is irrelevant, and the AMA Guides contains no figures describing its measurement. Figure 54, Measuring Internal and External Hip Rotation, demonstrates proper positioning and measurement techniques for rotary movements of this joint. The difference between measured and actual hip rotation probably is minimal and is irrelevant for impairment rating. The normal internal rotation varies from 30° to 40°, and the external rotation ranges from 40° to 60°.


1975 ◽  
Vol 30 (3) ◽  
pp. 315-330 ◽  
Author(s):  
Laurence R. Young ◽  
David Sheena

1984 ◽  
Vol 52 (03) ◽  
pp. 250-252 ◽  
Author(s):  
Y Sultan ◽  
Ph Avner ◽  
P Maisonneuve ◽  
D Arnaud ◽  
Ch Jeanneau

SummaryTwo monoclonal antibodies raised against FVIII/von Willebrand protein were used in an immunoradiometric assay (IRMA) to measure this antigen in normal plasma and plasma of patients with different forms of von Willebrand’s disease. The first antibody, an IgG1 was used to coat polystyrene tubes, the second one, an IgG2a, iodinated and used in the second step. Both antibodies inhibit ristocetin induced platelet agglutination and react strongly with platelets, megacaryocytes and endothelial cells. The IRMA test using these antibodies showed greater sensitivity than that using rabbit polyclonal anti VIIIRAg antibodies. A good correlation between the two tests was nevertheless found when VIIIRAg was measured in the majority of patient’s plasma. However 5 patients from 3 different families showed more antigenic material in the rabbit antibody IRMA than in the monoclonal antibody IRMA. It is suggested therefore that the monoclonal antibodies identify part of the VIIIR:Ag molecule showing structural abnormalities in these vWd patients, these structural changes remaining undetected by the polyclonal antibodies.


Sign in / Sign up

Export Citation Format

Share Document