scholarly journals Dynamic security of islanded power systems with pumped storage power plants for high renewable integration – A study case

2019 ◽  
Vol 2019 (18) ◽  
pp. 4955-4960
Author(s):  
Maria Helena Vasconcelos ◽  
Pedro Beires ◽  
Carlos Leal Moreira ◽  
João Abel Peças Lopes
2018 ◽  
Vol 4 (1) ◽  
pp. 77-86
Author(s):  
Nuno Fonseca ◽  
André Madureira ◽  
João Peças Lopes ◽  
Manuel Matos

This work is within the scope of set of consultancy studies made for Portuguese islands. It focuses on the integration of Pumped Storage Power in isolated islands. The paper starts to address several power systems circumstances about two Portuguese islands on the energetic level. For each of these islands, an independent examination of the conditions to install a reversible hydro power plant is accomplished. Therefore, the energy volume to be stored due to excess of renewable generation and the ideal power and number of the pumps and turbines to be installed were identified and evaluated for the sake of using the produced energy surplus as to be pumped and later generated. The paper enhances the importance of storing energy in the operation of isolated and small systems with considerable amount of intermittent power resources as well as the conditions for the viability of installing new exploitations of this kind.


2019 ◽  
Vol 139 ◽  
pp. 01009
Author(s):  
Murodilla Mukhammadiev ◽  
Boborakhim Urishev ◽  
Shirin Esemuratova ◽  
Nigina Djumaniyozova

This article deals with the analysis and development perspectives of the use pumped storage power plants use to increase the reliability and regime controllability of electric power systems of the Republic of Uzbekistan.


2014 ◽  
Vol 15 ◽  
pp. 37-41 ◽  
Author(s):  
Neeraj Kumar Sah ◽  
Madhab Uprety ◽  
Sangharsha Bhandari ◽  
Prativa Kharel ◽  
Saurav Suman ◽  
...  

An Integrated Power System (IPS) should have electrical energy generating plants for base load (e.g., nuclear and thermal plants) and peak load (e.g., hydropower plants) so that they can work in coordination in such a way that the demand is met in time. In Nepal, the Integrated Nepal Power System (INPS) is a hydro-dominated system where the base and intermediate power demands are covered primarily by run-of-river hydropower plants and the peak demand by seasonal storage and several diesel power plants of lower capacity. The INPS should have sufficient natural storage and forced storage power plants to improve the system’s reliability. On top of that, daily peak electrical demand could also be adequately covered by demand-side management, using a pumped-storage hydropower plant that can employ a system’s surplus energy during low demand period for pumping. To rectify this extreme imbalance of installed capacity in Nepal, this paper explores the prospect of storage and pumped-storage power plants for enhancing INPS. A case study of Rupa-Begnas pumped-storage hydropower is highlighted for these purposes.DOI: http://dx.doi.org/10.3126/hn.v15i0.11290HYDRO Nepal JournalJournal of Water, Energy and EnvironmentVolume: 15, 2014, JulyPage: 37-41 


2017 ◽  
Vol 12 (1) ◽  
pp. 73
Author(s):  
Sandra Camila Garzon ◽  
Mario Alberto Rios ◽  
Oscar Gomez

2019 ◽  
Vol 8 (4) ◽  
pp. 9449-9456

This paper proposes the reliability index of wind-solar hybrid power plants using the expected energy not supplied method. The location of this research is wind-solar hybrid power plants Pantai Baru, Bantul, Special Region of Yogyakarta, Indonesia. The method to determine the reliability of the power plant is the expected energy not supplied (EENS) method. This analysis used hybrid plant operational data in 2018. The results of the analysis have been done on the Pantai Baru hybrid power plant about reliability for electric power systems with EENS. The results of this study can be concluded that based on the load duration curve, loads have a load more than the operating kW of the system that is 99 kW. In contrast, the total power contained in the Pantai Baru hybrid power plant is 90 kW. This fact makes the system forced to release the load. The reliability index of the power system in the initial conditions, it produces an EENS value in 2018, resulting in a total value of 2,512% or 449 kW. The EENS value still does not meet the standards set by the National Electricity Market (NEM), which is <0.002% per year. Based on this data, it can be said that the reliability of the New Coast hybrid power generation system in 2018 is in the unreliable category.