Optimum modulation frequency for FM seeded FSF laser ranging

2006 ◽  
Vol 153 (6) ◽  
pp. 284-286 ◽  
Author(s):  
K.A. Shore ◽  
D.M. Kane
2019 ◽  
Author(s):  
Le Wang ◽  
Devon Jakob ◽  
Haomin Wang ◽  
Alexis Apostolos ◽  
Marcos M. Pires ◽  
...  

<div>Infrared chemical microscopy through mechanical probing of light-matter interactions by atomic force microscopy (AFM) bypasses the diffraction limit. One increasingly popular technique is photo-induced force microscopy (PiFM), which utilizes the mechanical heterodyne signal detection between cantilever mechanical resonant oscillations and the photo induced force from light-matter interaction. So far, photo induced force microscopy has been operated in only one heterodyne configuration. In this article, we generalize heterodyne configurations of photoinduced force microscopy by introducing two new schemes: harmonic heterodyne detection and sequential heterodyne detection. In harmonic heterodyne detection, the laser repetition rate matches integer fractions of the difference between the two mechanical resonant modes of the AFM cantilever. The high harmonic of the beating from the photothermal expansion mixes with the AFM cantilever oscillation to provide PiFM signal. In sequential heterodyne detection, the combination of the repetition rate of laser pulses and polarization modulation frequency matches the difference between two AFM mechanical modes, leading to detectable PiFM signals. These two generalized heterodyne configurations for photo induced force microscopy deliver new avenues for chemical imaging and broadband spectroscopy at ~10 nm spatial resolution. They are suitable for a wide range of heterogeneous materials across various disciplines: from structured polymer film, polaritonic boron nitride materials, to isolated bacterial peptidoglycan cell walls. The generalized heterodyne configurations introduce flexibility for the implementation of PiFM and related tapping mode AFM-IR, and provide possibilities for additional modulation channel in PiFM for targeted signal extraction with nanoscale spatial resolution.</div>


2002 ◽  
Vol 13 (04) ◽  
pp. 188-204 ◽  
Author(s):  
Shigeyuki Kuwada ◽  
Julia S. Anderson ◽  
Ranjan Batra ◽  
Douglas C. Fitzpatrick ◽  
Natacha Teissier ◽  
...  

The scalp-recorded amplitude-modulation following response (AMFR)” is gaining recognition as an objective audiometric tool, but little is known about the neural sources that underlie this potential. We hypothesized, based on our human studies and single-unit recordings in animals, that the scalp-recorded AMFR reflects the interaction of multiple sources. We tested this hypothesis using an animal model, the unanesthetized rabbit. We compared AMFRs recorded from the surface of the brain at different locations and before and after the administration of agents likely to enhance or suppress neural generators. We also recorded AMFRs locally at several stations along the auditory neuraxis. We conclude that the surface-recorded AMFR is indeed a composite response from multiple brain generators. Although the response at any modulation frequency can reflect the activity of more than one generator, the AMFRs to low and high modulation frequencies appear to reflect a strong contribution from cortical and subcortical sources, respectively.


2002 ◽  
Vol 13 (05) ◽  
pp. 260-269 ◽  
Author(s):  
Barbara Cone-Wesson ◽  
John Parker ◽  
Nina Swiderski ◽  
Field Rickards

Two studies were aimed at developing the auditory steady-state response (ASSR) for universal newborn hearing screening. First, neonates who had passed auditory brainstem response, transient evoked otoacoustic emission, and distortion-product otoacoustic emission tests were also tested with ASSRs using modulated tones that varied in frequency and level. Pass rates were highest (> 90%) for amplitude-modulated tones presented at levels ≥ 69 dB SPL. The effect of modulation frequency on ASSR for 500- and 2000-Hz tones was evaluated in full-term and premature infants in the second study. Full-term infants had higher pass rates for 2000-Hz tones amplitude modulated at 74 to 106 Hz compared with pass rates for a 500-Hz tone modulated at 58 to 90 Hz. Premature infants had lower pass rates than full-term infants for both carrier frequencies. Systematic investigation of ASSR threshold and the effect of modulation frequency in neonates is needed to adapt the technique for screening.


Author(s):  
C. Veillet ◽  
J. F. Mangin ◽  
J. E. Chabaubie ◽  
C. Dumolin ◽  
D. Feraudy ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document