Investigation of transient induced voltage to a communication line from an overhead power transmission line

1990 ◽  
Vol 137 (2) ◽  
pp. 129 ◽  
Author(s):  
T. Imamura ◽  
A. Ametani
Author(s):  
G. A. Bolshanin ◽  
M. P. Plotnikov

Electrical energy from the place of its generation is transmitted to consumers of various capacities. The distance from the source of electrical energy to the consumer can vary from several meters to several thousand kilometers. In this regard, the accurate determination of the operating parameters of the power transmission line (PTL) is a mandatory and necessary condition for the PTL normal functioning. In the current-carrying parts of the double-circuit PTL there are six incident and six reflected waves of the electromagnetic field. They determine voltages and currents. A scheme is proposed for the distribution of these waves along linear wires of a homogeneous section of a double-circuit PTL. This scheme shows that the current-carrying parts of the adjacent wires have a significant impact on voltages and currents in one wire. This scheme illustrates the distribution of the amplitude values of electromagnetic field waves, defined as the integration constant. Using the integration constants, the propagation constants of electromagnetic waves along the linear wires of the PTL and the corresponding wave impedances, one can obtain the amplitude values of the incident and reflected waves at any point of the double- circuit PTL, and hence the currents and voltages in the double-circuit PTL. The article presents a method for determining the currents and voltages in a double-circuit PTL according to the load. The proposed method will allow determining the qualitative and quantitative indicators of electrical energy (induced voltage) appearing from each wire separately and provide the possibility of their elimination, which will improve the quality of electrical energy.


2017 ◽  
Vol 66 (3) ◽  
pp. 595-605 ◽  
Author(s):  
Ramūnas Deltuva ◽  
Robertas Lukočius

AbstractIn Lithuanian and Polish electric power supply systems, the power transmission lines of 400 kV voltage represent one of the most potential sources of electric and magnetic fields generation. The 400 kV double-circuit overhead power transmission line and its surrounding environment were herby described and simulated through Finite Element Method usingCOMSOL Multiphysicsoftware package. This study includes magnetic and electric field calculations. The study shows that the values of magnetic field strength and electric field strength present in the vicinity of a 400 kV overhead power transmission line tend to exceed limit values established in the Normative. Measurements are suggested to be taken for the purpose of finding maximum values of magnetic and electric field strength. To reduce these values, it is recommended to increase the height of supports, and restrict human personal and economic activities.


2021 ◽  
pp. 1-1
Author(s):  
Zhewen Ding ◽  
Xuping Zhang ◽  
Ningmu Zou ◽  
Fei Xiong ◽  
Jinyu Song ◽  
...  

Sign in / Sign up

Export Citation Format

Share Document