Application of a new distance protection scheme to a single-pole autotransformer electrification system on the UK West Coast main line railway

Author(s):  
D.B. Hewings ◽  
J. Chen ◽  
A.P. Storey
Radiocarbon ◽  
2001 ◽  
Vol 43 (2B) ◽  
pp. 517-525 ◽  
Author(s):  
D Gallagher ◽  
E J McGee ◽  
P I Mitchell

Data on radiocarbon (14C), 137Cs, 210Pb, and 241Am levels in an ombrotrophic peat sequence from a montane site on the east coast of Ireland are compared with data from a similar sequence at an Atlantic peatland site on the west coast. The 14C profiles from the west and east coasts show a broadly similar pattern. Levels increase from 100 pMC or less in the deepest horizons examined, to peak values at the west and east coast sites of 117 ± 0.6 pMC and 132 ± 0.7 pMC, respectively (corresponding to maximal fallout from nuclear weapons testing around 1964), thereafter diminishing to levels of 110–113 pMC near the surface. Significantly, peak levels at the east coast site are considerably higher than corresponding levels at the west coast site, though both are lower than reported peak values for continental regions. The possibility of significant 14C enrichment at the east coast site due to past discharges from nuclear installations in the UK seems unlikely. The 210Pbex inventory at the east coast site (6500 Bq m−2) is significantly higher than at the west coast (5300 Bq m−2) and is consistent with the difference in rainfall at the two sites. Finally, 137Cs and 241Am inventories at the east coast site also exceed those at the west coast site by similar proportions (east:west ratio of approximately 1:1.2).


2018 ◽  
Vol 7 (3) ◽  
pp. 223-231
Author(s):  
Saad Muftah Saad ◽  
Naser El Naily ◽  
Faisal A. Mohamed

The environmental and economic features of renewable energy sources have made it possible to be integrated as Distributed Generation (DG) units in distribution networks and to be widely utilized in modern distribution systems. The intermittent nature of renewable energy sources, altering operational conditions, and the complex topology of active distribution networks makes the level of fault currents significantly variable. Thus, the use of distance protection scheme instead of conventional overcurrent schemes offers an appropriate alternative for protection of modern distribution networks. In this study, the effect of integrating multiple DG units on the effective cover of distance protection schemes and the coordination between various relays in the network was studied and investigated in radiology and meshed operational topologies. Also, in cases of islanded and grid-connected modes. An adaptive distance scheme has been proposed for adequate planning of protection schemes to protect complex networks with multiple distribution sources. The simplified simulated network implemented in NEPLAN represents a benchmark IEC microgrid. The comprehensive results show an effective protection measure for secured microgrid operation.Article History: Received October 18th 2017; Received in revised form May 17th 2018; Accepted July 8th 2018; Available onlineHow to Cite This Article: Saad, S.M., Naily, N.E. and Mohamed, F.A. (2018). Investigating the Effect of DG Infeed on the Effective Cover of Distance Protection Scheme in Mixed-MV Distribution Network. International Journal of Renewable Energy Development, 7(3), 223-231.https://doi.org/10.14710/ijred.7.3.223-231


Sign in / Sign up

Export Citation Format

Share Document