High frequency observations and characterizations of coherent backscatters from midlatitude E-region

1997 ◽  
Author(s):  
A. Huar
Keyword(s):  
1953 ◽  
Vol 31 (2) ◽  
pp. 171-181 ◽  
Author(s):  
D. W. R. McKinley ◽  
Peter M. Millman

In the course of the Ottawa meteor program some unusual echoes have been detected on 33 Mc. Echoes from the aurora are discussed and correlated with visual observations. Two mechanisms of radio reflections from the aurora have been proposed but the data here presented are insufficient to favor one over the other. On Aug. 4, 1948, six extremely long duration meteor echoes were observed which may have been due to abnormal ionospheric conditions. From time to time since August, 1948, a weak semipermanent echo has been recorded, usually appearing at a range of about 80 km., and enduring up to an hour. It is suggested that this echo is due to back-scatter from the same sources in the lower E-region that are presumed to be responsible for long-range very high frequency propagation.


1991 ◽  
Vol 69 (8-9) ◽  
pp. 941-949
Author(s):  
Joëlle Margot ◽  
A. G. McNamara

Probe measurements of plasma irregularities in the lower E region during an auroral event showed the presence of coherent wave forms with a wavelength extending down to 35 cm that can be explained by the Farley–Buneman instability. Our results can be interpreted in the frame of recent theories of electron heating by unstable waves. Our data provide experimental evidence that coherent short-wavelength waves can be excited as is assumed in these theories. The measurements were made from rocket AAD-VIIIC-09 (ARIES-A) that formed part of the ARIES campaign for auroral modelling.


2021 ◽  
Author(s):  
Wenjie Sun ◽  
Baiqi Ning ◽  
Lianhuan Hu ◽  
Xiukuan Zhao ◽  
Guozhu Li

<p>Early and recent observations suggested that E-region field aligned irregularities (FAIs) related closely to the sporadic E (Es) layer of the ionosphere. The Sanya (18.3 ºN, 109.6 ºE) very high frequency (VHF) radar can operate at ionospheric irregularities mode for the detection of 3-m scale FAIs. The development of a portable digital ionosonde (PDI) which is collocated with the Sanya VHF radar can operate with temporal periods down to 1 minute, facilitating the capability of capturing the fast evolution of Es structures. But the low spatial resolution of the two kinds of instruments makes it difficult to depict the horizontal morphology of the Es structures and E-region FAIs. Since the capability of ground-based GNSS in strong Es detection was presented, it serves as a perfect supplement for the investigation of E region of the ionosphere. So comprehensive observation with multi kinds of instruments makes it possible to reveal the relationship and mechanisms of Es and E-region FAIs.</p><p>A complex daytime sporadic E (Es) case with extremely high critical frequency (foEs) was observed over the low latitude of China on 19 May 2018. Simultaneous observational results from two very high frequency (VHF) radars, two ionosondes, and multiple Global Navigation Satellite System total electron content and scintillation receivers are analyzed to investigate the evolution of the complex Es occurrence, which consisted of a relatively weak ambient Es layer (foEs < 8 MHz) and band-like strong Es structures (foEs > 17 MHz) drifting from higher latitude. The strong Es structures elongated more than 500 km in the northwest-southeast direction, drifted southwestward at a speed of ~65 m/s. VHF radar backscatter echoes were generated when the strong Es structures passed the radar field of view, with different echo patterns due to different radar and antenna configurations. No VHF radar backscatter echo was associated with the ambient Es layer.</p>


Author(s):  
W. E. Lee ◽  
A. H. Heuer

IntroductionTraditional steatite ceramics, made by firing (vitrifying) hydrous magnesium silicate, have long been used as insulators for high frequency applications due to their excellent mechanical and electrical properties. Early x-ray and optical analysis of steatites showed that they were composed largely of protoenstatite (MgSiO3) in a glassy matrix. Recent studies of enstatite-containing glass ceramics have revived interest in the polymorphism of enstatite. Three polymorphs exist, two with orthorhombic and one with monoclinic symmetry (ortho, proto and clino enstatite, respectively). Steatite ceramics are of particular interest a they contain the normally unstable high-temperature polymorph, protoenstatite.Experimental3mm diameter discs cut from steatite rods (∼10” long and 0.5” dia.) were ground, polished, dimpled, and ion-thinned to electron transparency using 6KV Argon ions at a beam current of 1 x 10-3 A and a 12° angle of incidence. The discs were coated with carbon prior to TEM examination to minimize charging effects.


Author(s):  
G. Y. Fan ◽  
J. M. Cowley

It is well known that the structure information on the specimen is not always faithfully transferred through the electron microscope. Firstly, the spatial frequency spectrum is modulated by the transfer function (TF) at the focal plane. Secondly, the spectrum suffers high frequency cut-off by the aperture (or effectively damping terms such as chromatic aberration). While these do not have essential effect on imaging crystal periodicity as long as the low order Bragg spots are inside the aperture, although the contrast may be reversed, they may change the appearance of images of amorphous materials completely. Because the spectrum of amorphous materials is continuous, modulation of it emphasizes some components while weakening others. Especially the cut-off of high frequency components, which contribute to amorphous image just as strongly as low frequency components can have a fundamental effect. This can be illustrated through computer simulation. Imaging of a whitenoise object with an electron microscope without TF limitation gives Fig. 1a, which is obtained by Fourier transformation of a constant amplitude combined with random phases generated by computer.


Author(s):  
M. T. Postek ◽  
A. E. Vladar

Fully automated or semi-automated scanning electron microscopes (SEM) are now commonly used in semiconductor production and other forms of manufacturing. The industry requires that an automated instrument must be routinely capable of 5 nm resolution (or better) at 1.0 kV accelerating voltage for the measurement of nominal 0.25-0.35 micrometer semiconductor critical dimensions. Testing and proving that the instrument is performing at this level on a day-by-day basis is an industry need and concern which has been the object of a study at NIST and the fundamentals and results are discussed in this paper.In scanning electron microscopy, two of the most important instrument parameters are the size and shape of the primary electron beam and any image taken in a scanning electron microscope is the result of the sample and electron probe interaction. The low frequency changes in the video signal, collected from the sample, contains information about the larger features and the high frequency changes carry information of finer details. The sharper the image, the larger the number of high frequency components making up that image. Fast Fourier Transform (FFT) analysis of an SEM image can be employed to provide qualitiative and ultimately quantitative information regarding the SEM image quality.


1992 ◽  
Vol 1 (4) ◽  
pp. 52-55 ◽  
Author(s):  
Gail L. MacLean ◽  
Andrew Stuart ◽  
Robert Stenstrom

Differences in real ear sound pressure levels (SPLs) with three portable stereo system (PSS) earphones (supraaural [Sony Model MDR-44], semiaural [Sony Model MDR-A15L], and insert [Sony Model MDR-E225]) were investigated. Twelve adult men served as subjects. Frequency response, high frequency average (HFA) output, peak output, peak output frequency, and overall RMS output for each PSS earphone were obtained with a probe tube microphone system (Fonix 6500 Hearing Aid Test System). Results indicated a significant difference in mean RMS outputs with nonsignificant differences in mean HFA outputs, peak outputs, and peak output frequencies among PSS earphones. Differences in mean overall RMS outputs were attributed to differences in low-frequency effects that were observed among the frequency responses of the three PSS earphones. It is suggested that one cannot assume equivalent real ear SPLs, with equivalent inputs, among different styles of PSS earphones.


2019 ◽  
Vol 28 (1S) ◽  
pp. 209-224 ◽  
Author(s):  
Julia Campbell ◽  
Alison LaBrec ◽  
Connor Bean ◽  
Mashhood Nielsen ◽  
Won So

2020 ◽  
Vol 29 (3) ◽  
pp. 429-435
Author(s):  
Patricia C. Mancini ◽  
Richard S. Tyler ◽  
Hyung Jin Jun ◽  
Tang-Chuan Wang ◽  
Helena Ji ◽  
...  

Purpose The minimum masking level (MML) is the minimum intensity of a stimulus required to just totally mask the tinnitus. Treatments aimed at reducing the tinnitus itself should attempt to measure the magnitude of the tinnitus. The objective of this study was to evaluate the reliability of the MML. Method Sample consisted of 59 tinnitus patients who reported stable tinnitus. We obtained MML measures on two visits, separated by about 2–3 weeks. We used two noise types: speech-shaped noise and high-frequency emphasis noise. We also investigated the relationship between the MML and tinnitus loudness estimates and the Tinnitus Handicap Questionnaire (THQ). Results There were differences across the different noise types. The within-session standard deviation averaged across subjects varied between 1.3 and 1.8 dB. Across the two sessions, the Pearson correlation coefficients, range was r = .84. There was a weak relationship between the dB SL MML and loudness, and between the MML and the THQ. A moderate correlation ( r = .44) was found between the THQ and loudness estimates. Conclusions We conclude that the dB SL MML can be a reliable estimate of tinnitus magnitude, with expected standard deviations in trained subjects of about 1.5 dB. It appears that the dB SL MML and loudness estimates are not closely related.


Sign in / Sign up

Export Citation Format

Share Document