Testing of Protection in a Digital Substation Protection Automation and Control System (SPACS)

Author(s):  
R.S.J. Loken ◽  
A. Apostolov
Sensors ◽  
2021 ◽  
Vol 21 (2) ◽  
pp. 538
Author(s):  
Nicoleta Cristina Gaitan ◽  
Ioan Ungurean

The development of the smart building concept and building automation field is based on the exponential evolution of monitoring and control technologies. Residents of the smart building must interact with the monitoring and control system. A widely used method is specific applications executed on smartphones, tablets, and PCs with Bluetooth connection to the building control system. At this time, smartphones are increasingly used in everyday life for payments, reading newspapers, monitoring activity, and interacting with smart homes. The devices used to build the control system are interconnected through a specific network, one of the most widespread being the Building Automation and Control Network (BACnet) network. Here, we propose the use of the BACnet Application Layer over Bluetooth. We present a proposal of a concept and a practical implementation that can be used to test and validate the operation of the BACnet Application Layer over Bluetooth.


Energies ◽  
2021 ◽  
Vol 14 (8) ◽  
pp. 2337
Author(s):  
Linwei Chen ◽  
Haiyu Li ◽  
Thomas Charton ◽  
Ray Zhang

Interoperability testing and analysis tools provide a means for achieving and assuring the integrity of multivendor intelligent electronic devices (IEDs) data exchanges. However, the testing and analysis are very time consuming and error prone, and these problems worsen when a substation becomes large and complex during the engineering process, commission, replacement, maintenance, and extension. To address this challenge, this paper presents a virtual digital substation test system (VDSTS) with interoperability analysis tools for assessing and identifying the engineering challenges for the multiple-vendors digital substation. This VDSTS consists of three parts: (i) A virtual digital substation modelling for generating real-time digital substation primary plant operation and fault conditions, (ii) a standard IEC 61850-based substation protection, automation, and control (PAC) system architecture with multivendor IEDs and bay solutions, and (iii) multivendor Substation Configuration description Language (SCL) tools and in-house built data visualisation tool. The study focuses on the interoperability testing of sampled values (SV), generic object-oriented substation events (GOOSE), and manufacturing message specification (MMS) communication services, as defined in IEC 61850. The main issues identified are compatibility issues of SCL tools, protocol implementation issues, different information models, and application limitations. The outcomes will help utilities to reduce the risks associated with the general rollout of digital substations.


TECCIENCIA ◽  
2017 ◽  
Vol 11 (23) ◽  
Author(s):  
Jhon Elier Arango Trillos ◽  
Cristhian Manuel Duran Acevedo ◽  
Jhon Edward Lizarazo Parada ◽  
Jorge Antonio Duarte Noriega

Sign in / Sign up

Export Citation Format

Share Document