Hearing Loss, Speech, and Hearing Aids

1993 ◽  
Vol 36 (2) ◽  
pp. 228-244 ◽  
Author(s):  
Dianne J. Van Tasell

Modern hearing aids permit adjustment of a number of electroacoustic parameters, among them frequency response, saturation sound pressure level, and various aspects of compression. Relatively little is known, however, about how the electroacoustic characteristics of hearing aids affect the information-bearing properties of speech. Even less is known about how hearing aids might alleviate or exacerbate the effects of impaired hearing. This article reviews current knowledge in three areas: (a) characteristics of mild/moderate hearing loss, (b) informationbearing aspects of speech, and (c) the relation between electroacoustic characteristics of hearing aids and the speech signal. Concluding suggestions are made regarding the implications of the current data for selecting hearing-aid characteristics.

1974 ◽  
Vol 39 (2) ◽  
pp. 163-168 ◽  
Author(s):  
Lynne Marshall ◽  
John F. Brandt

Temporary threshold shift resulting from exposure to one and five toy cap gun pistol shots was investigated using 11 normal-hearing adult subjects and one subject with a noise-induced hearing loss. The subjects fired the cap gun at arm’s length, and absolute thresholds at 4000 Hz were obtained before and after noise exposure by a fixed-frequency Bekesy technique. After exposure to one gunshot, five subjects showed a small TTS, five demonstrated no TTS, and two (including the subject with the hearing loss) exhibited negative TTS. No TTS occurred in any of the subjects after exposure to five shots. It was postulated that the small amount of TTS was due to the unexpectedly low sound pressure level produced by the cap gun and to the contraction of the middle ear muscles in some subjects prior to firing.


2012 ◽  
Vol 23 (09) ◽  
pp. 733-750
Author(s):  
Karrie LaRae Recker ◽  
Tao Zhang ◽  
Weili Lin

Background: Sound pressure-based real ear measurements are considered best practice for ensuring audibility among individuals fitting hearing aids. The accuracy of current methods is generally considered clinically acceptable for frequencies up to about 4 kHz. Recent interest in the potential benefits of higher frequencies has brought about a need for an improved, and clinically feasible, method of ensuring audibility for higher frequencies. Purpose: To determine whether (and the extent to which) average correction factors could be used to improve the estimated high-frequency sound pressure level (SPL) near the tympanic membrane (TM). Research Design: For each participant, real ear measurements were made along the ear canal, at 2–16 mm from the TM, in 2-mm increments. Custom in-ear monitors were used to present a stimulus with frequency components up to 16 kHz. Study Sample: Twenty adults with normal middle-ear function participated in this study. Intervention: Two methods of creating and implementing correction factors were tested. Data Collection and Analysis: For Method 1, correction factors were generated by normalizing all of the measured responses along the ear canal to the 2-mm response. From each normalized response, the frequency of the pressure minimum was determined. This frequency was used to estimate the distance to the TM, based on the ¼ wavelength of that frequency. All of the normalized responses with similar estimated distances to the TM were grouped and averaged. The inverse of these responses served as correction factors. To apply the correction factors, the only required information was the frequency of the pressure minimum. Method 2 attempted to, at least partially, account for individual differences in TM impedance, by taking into consideration the frequency and the width of the pressure minimum. Because of the strong correlation between a pressure minimum's width and depth, this method effectively resulted in a group of average normalized responses with different pressure-minimum depths. The inverse of these responses served as correction factors. To apply the correction factors, it was necessary to know both the frequency and the width of the pressure minimum. For both methods, the correction factors were generated using measurements from one group of ten individuals and verified using measurements from a second group of ten individuals. Results: Applying the correction factors resulted in significant improvements in the estimated SPL near the TM for both methods. Method 2 had the best accuracy. For frequencies up to 10 kHz, 95% of measurements had <8 dB of error, which is comparable to the accuracy of real ear measurement methods that are currently used clinically below 4 kHz. Conclusions: Average correction factors can be successfully applied to measurements made along the ear canals of otologically healthy adults, to improve the accuracy of the estimated SPL near the TM in the high frequencies. Further testing is necessary to determine whether these correction factors are appropriate for pediatrics or individuals with conductive hearing losses.


1978 ◽  
Vol 86 (1) ◽  
pp. ORL-125-ORL-128 ◽  
Author(s):  
Allen F. Ryan ◽  
Robert C. Bone

Chinchillas were exposed to a noise band (1,414 to 5,656 Hz, 100-dB sound pressure level [SPL] for one hour) and treated with kanamycin (150 mg/kg a day until hearing loss was noted at 6.0 kHz) either separately, simultaneously, or sequentially. Simultaneous noise and kanamycin resulted in interactive potentiation of threshold shift and cochlear pathologic condition. Kanamycin treatment two months after noise exposure produced similar potentiation. No interaction was seen when noise exposure occurred one month after kanamycin treatment.


Work ◽  
2021 ◽  
pp. 1-7
Author(s):  
Carina Moreno Dias Carneiro Muniz ◽  
Sergio Fernando Saraiva da Silva ◽  
Rachel Costa Façanha ◽  
Daniela Bassi-Dibai ◽  
Fabricio Brito Silva ◽  
...  

BACKGROUND: Musicians and dancers can be considered an at-risk population for developing noise-induced hearing loss. OBJECTIVES: To determine the audiological profile of members of a folklore-related music group and quantify noise exposure at their rehearsal venue. METHODS: This was a quantitative and descriptive study. The musicians and dancers were evaluated in two stages: an interview about their working life, followed by high frequency tonal audiometry. The sound pressure level in the group’s rehearsal venue was measured using a BEK 2270 Noise Analyzer. RESULTS: A total of 7.2% of the subjects had noise-induced hearing loss (NIHL) and 39% of the audiometric tests were notch type. During the interview 31.7% of the subjects mentioned discomfort from loud noise, although none of them used ear protection. The environmental assessment showed inadequate humidity and oscillating temperature. Twenty sound pressure level measurements were performed for Leq (equivalent sound pressure levels) and the results ranged from 88 dB (A) to 99 dB (A) with a mean of 97.05. CONCLUSIONS: Exposure to high levels of sound pressure has led to NIHL in some members of the group. Some of those with normal hearing also presented a notch configuration characteristic of NIHL. Tinnitus, indicating that a change in hearing has occurred, was the most frequent auditory symptom.


2011 ◽  
Vol 145 ◽  
pp. 63-67
Author(s):  
Jen Fang Yu ◽  
Wei De Cheng

This study was to measure the sound pressure level distribution by ear canal resonance in the human left and right external auditory canals (EAC). The gain for different stimulus frequencies was analyzed at four different measuring depths (0.5 cm, 1.0 cm, 1.5 cm and 2.0 cm) from the entrance of the ear canal bilaterally. Comparative evaluation showed that the gain for different stimulus frequencies at a depth of 2.0 cm was consistent with the results of Dillon’s study. In addition, the gain for the right EAC at 4000 Hz was larger than that of the left EAC by 1.2 dB at 0.5 cm, 1.8 dB at 1.0 cm, and 0.8 dB at 1.5 cm. This seems to suggest that gain at 4000 Hz is more affected by depth in the right EAC than in the left EAC. This study further found that the gain at the stimulus frequency of 4000 Hz was more affected by the depth than at 2000 Hz for the bilateral ear canals respectively. These gain differences between the right and left ears were statistically significant (p<0.05) at any of four measuring depths. The findings of this study may have an understanding of gain distribution to have implications for microphone placement of custom-made bilateral hearing aids (i.e. ITC or CIC) as these are placed at different depths within the ear canal. Keywords: Sound pressure level; Canal depth; Ear canal resonance; Real ear measurement; External auditory canal


2017 ◽  
Vol 31 (19-21) ◽  
pp. 1740059 ◽  
Author(s):  
Ruiyu Liang ◽  
Ji Xi ◽  
Yongqiang Bao

To improve the performance of gain compensation based on three-segment sound pressure level (SPL) in hearing aids, an improved multichannel loudness compensation method based on eight-segment SPL was proposed. Firstly, the uniform cosine modulated filter bank was designed. Then, the adjacent channels which have low or gradual slopes were adaptively merged to obtain the corresponding non-uniform cosine modulated filter according to the audiogram of hearing impaired persons. Secondly, the input speech was decomposed into sub-band signals and the SPL of every sub-band signal was computed. Meanwhile, the audible SPL range from 0 dB SPL to 120 dB SPL was equally divided into eight segments. Based on these segments, a different prescription formula was designed to compute more detailed gain to compensate according to the audiogram and the computed SPL. Finally, the enhanced signal was synthesized. Objective experiments showed the decomposed signals after cosine modulated filter bank have little distortion. Objective experiments showed that the hearing aids speech perception index (HASPI) and hearing aids speech quality index (HASQI) increased 0.083 and 0.082 on average, respectively. Subjective experiments showed the proposed algorithm can effectively improve the speech recognition of six hearing impaired persons.


Sign in / Sign up

Export Citation Format

Share Document