Coupling of FM Systems to Individuals With Unilateral Hearing Loss

1992 ◽  
Vol 35 (1) ◽  
pp. 201-207 ◽  
Author(s):  
Judy G. Kopun ◽  
Patricia G. Stelmachowicz ◽  
Edward Carney ◽  
Laura Schulte

This study examined the attenuation characteristics of five FM system sound delivery options for a group of 10 adults and 15 children (5–13 years). Sound delivery options included a tube-fitting, lightweight headphones, a CROS earmold with tubing, a CROS earmold with a snap-ring, and a standard snap-ring earmold with a vent. Attenuation was defined as the difference between probe-tube microphone measures of the ear canal resonance and the SPL in the ear canal with each sound delivery option in place. A statistically significant but clinically inconsequential difference in attenuation for the CROS earmold with tubing was noted between adults and children. No significant differences in attenuation for any of the other sound delivery options were noted between adults and children. An investigation of the relationship between magnitude of attenuation and percentage of the ear canal occluded suggests that degree of occlusion is a major factor in determining degree of attenuation provided by a particular sound delivery option. Results also indicate that significant attenuation of high-frequency signals can occur with earmolds commonly considered nonoccluding. Caution should be used in fitting hearing aids or FM systems to individuals with normal high-frequency hearing sensitivity to prevent attenuation of unamplified high-frequency speech information.

1986 ◽  
Vol 51 (4) ◽  
pp. 362-369 ◽  
Author(s):  
Donna M. Risberg ◽  
Robyn M. Cox

A custom in-the-ear (ITE) hearing aid fitting was compared to two over-the-ear (OTE) hearing aid fittings for each of 9 subjects with mild to moderately severe hearing losses. Speech intelligibility via the three instruments was compared using the Speech Intelligibility Rating (SIR) test. The relationship between functional gain and coupler gain was compared for the ITE and the higher rated OTE instruments. The difference in input received at the microphone locations of the two types of hearing aids was measured for 10 different subjects and compared to the functional gain data. It was concluded that (a) for persons with mild to moderately severe hearing losses, appropriately adjusted custom ITE fittings typically yield speech intelligibility that is equal to the better OTE fitting identified in a comparative evaluation; and (b) gain prescriptions for ITE hearing aids should be adjusted to account for the high-frequency emphasis associated with in-the-concha microphone placement.


2018 ◽  
Vol 29 (06) ◽  
pp. 520-532 ◽  
Author(s):  
Jonathan M. Vaisberg ◽  
Paula Folkeard ◽  
John Pumford ◽  
Philipp Narten ◽  
Susan Scollie

AbstractThe real-ear-to-coupler difference (RECD) is an ANSI standardized method for estimating ear canal sound pressure level (SPL) thresholds and assisting in the prediction of real-ear aided responses. It measures the difference in dB between the SPL produced in the ear canal and the SPL produced in an HA-1 2-cc coupler by the same sound source. Recent evidence demonstrates that extended high-frequency bandwidth, beyond the hearing aid bandwidth typically measured, is capable of providing additional clinical benefit. The industry has, in turn, moved toward developing hearing aids and verification equipment capable of producing and measuring extended high-frequency audible output. As a result, a revised RECD procedure conducted using a smaller, 0.4-cc coupler, known as the wideband-RECD (wRECD), has been introduced to facilitate extended high-frequency coupler-based measurements up to 12.5 kHz.This study aimed to (1) compare test–retest repeatability between the RECD and wRECD and (2) measure absolute agreement between the RECD and wRECD when both are referenced to a common coupler.RECDs and wRECDs were measured bilaterally in adult ears by calculating the dB difference in SPL between the ear canal and coupler responses. Real-ear probe microphone measures were completed twice per ear per participant for both foam-tip and customized earmold couplings using the Audioscan Verifit 1 and Verifit 2 fitting systems, followed by measurements in the respective couplers.Twenty-one adults (mean age = 67 yr, range = 19–78) with typical aural anatomy (as determined by measures of impedance and otoscopy) participated in this study, leading to a sample size of 42 ears.Repeatability within RECD and wRECD was assessed for each coupling configuration using a repeated-measures analysis of variance (ANOVA) with test–retest and frequency as within-participants factors. Repeatability between the RECD and wRECD was assessed within each configuration using a repeated-measures ANOVA with test–retest, frequency, and coupler type as within-participants factors. Agreement between the RECD and wRECD was assessed for each coupling configuration using a repeated-measures ANOVA with RECD value, coupler type, and frequency as within-participants factors. Post hoc comparisons with Bonferroni corrections were used when appropriate to locate the frequencies at which differences occurred. A 3-dB criterion was defined to locate differences of clinical significance.Average absolute test–retest differences were within ±3 dB within each coupler and coupling configuration, and between the RECD and wRECD. The RECD and wRECD were in absolute agreement following HA-1-referenced transforms, with most frequencies agreeing within ±1 dB, except at 0.2 kHz for the earmold, and 0.2–0.25 kHz for the foam tip, where the average RECD exceeded the average wRECD by slightly >3 dB.Test–retest repeatability of the RECD (up to 8 kHz) and wRECD (up to 12.5 kHz) is acceptable and similar to previously reported data. The RECD and wRECD are referenced to different couplers, but can be rendered comparable with a simple transform, producing values that are in accordance with the ANSI S3.46-2013 standard.


2021 ◽  
pp. 1-9
Author(s):  
Xunyi Wang ◽  
Yun Zheng ◽  
Gang Li ◽  
Jingzhe Lu ◽  
Yan Yin

<b><i>Introduction:</i></b> Outcome assessment for hearing aids (HAs) is an essential part of HA fitting and validation. There is no consensus about the best or standard approach for evaluating HA outcomes. And, the relationship between objective and subjective measures is ambiguous. This study aimed to determine the outcomes after HA fitting, explore correlations between subjective benefit and acoustic gain improvement as well as objective audiologic tests, and investigate several variables that may improve patients’ perceived benefits. <b><i>Methods:</i></b> Eighty adults with bilateral symmetrical hearing loss using HAs for at least 1 month were included in this study. All subjects completed the pure tone average (PTA) threshold and word recognition score (WRS) tests in unaided and aided conditions. We also administered the Chinese version of International Outcome Inventory for Hearing Aids (IOI-HA), to measure participants’ subjective benefits. Objective HA benefit (acoustic gain improvement) was defined as the difference in thresholds or scores between aided and unaided conditions indicated with ΔPTA and ΔWRS. Thus, patients’ baseline hearing levels were taken into account. Correlations were assessed among objective audiologic tests (PTA and WRS), acoustic gain improvement (ΔPTA and ΔWRS), multiple potential factors, and IOI-HA overall scores. <b><i>Results:</i></b> PTA decreased significantly, but WRS did not increase when aided listening was compared to unaided listening. Negative correlations between PTAs and IOI-HA scores were significant but weak (<i>r</i> = −0.370 and <i>r</i> = −0.393, all <i>p</i> &#x3c; 0.05). Significant weak positive correlations were found between WRSs and IOI-HA (<i>r</i> = 0.386 and <i>r</i> = 0.309, all <i>p</i> &#x3c; 0.05). However, there was no correlation among ΔPTA, ΔWRS, and IOI-HA (<i>r</i> = 0.056 and <i>r</i> = −0.086, all <i>p</i> &#x3e; 0.05). Moreover, 2 nonaudiological factors (age and daily use time) were significantly correlated with IOI-HA (<i>r</i> = −0.269 and <i>r</i> = 0.242, all <i>p</i> &#x3c; 0.05). <b><i>Conclusions:</i></b> Correlations among objective audiologic tests, acoustic gain, and subjective patient-reported outcomes were weak or absent. Subjective questionnaires and objective tests do not reflect the same hearing capability. Therefore, it is advisable to evaluate both objective and subjective outcomes when analyzing HA benefits on a regular basis and pay equal attention to nonaudiological and audiological factors.


2016 ◽  
Vol 27 (03) ◽  
pp. 264-275 ◽  
Author(s):  
Sheila Moodie ◽  
Jonathan Pietrobon ◽  
Eileen Rall ◽  
George Lindley ◽  
Leisha Eiten ◽  
...  

Background: Real-ear-to-coupler difference (RECD) measurements are used for the purposes of estimating degree and configuration of hearing loss (in dB SPL ear canal) and predicting hearing aid output from coupler-based measures. Accurate measurements of hearing threshold, derivation of hearing aid fitting targets, and predictions of hearing aid output in the ear canal assume consistent matching of RECD coupling procedure (i.e., foam tip or earmold) with that used during assessment and in verification of the hearing aid fitting. When there is a mismatch between these coupling procedures, errors are introduced. Purpose: The goal of this study was to quantify the systematic difference in measured RECD values obtained when using a foam tip versus an earmold with various tube lengths. Assuming that systematic errors exist, the second goal was to investigate the use of a foam tip to earmold correction for the purposes of improving fitting accuracy when mismatched RECD coupling conditions occur (e.g., foam tip at assessment, earmold at verification). Study Sample: Eighteen adults and 17 children (age range: 3–127 mo) participated in this study. Data Collection and Analysis: Data were obtained using simulated ears of various volumes and earmold tubing lengths and from patients using their own earmolds. Derived RECD values based on simulated ear measurements were compared with RECD values obtained for adult and pediatric ears for foam tip and earmold coupling. Results: Results indicate that differences between foam tip and earmold RECDs are consistent across test ears for adults and children which support the development of a correction between foam tip and earmold couplings for RECDs that can be applied across individuals. Conclusions: The foam tip to earmold correction values developed in this study can be used to provide improved estimations of earmold RECDs. This may support better accuracy in acoustic transforms related to transforming thresholds and/or hearing aid coupler responses to ear canal sound pressure level for the purposes of fitting behind-the-ear hearing aids.


2002 ◽  
Vol 13 (07) ◽  
pp. 356-366
Author(s):  
Therese C. Walden ◽  
Brian E. Walden ◽  
Mary T. Cord

This study compared the real-ear response provided by custom-fit hearing aids to the closest matching fixed-format disposable hearing aids in patients with precipitous high-frequency hearing loss. Laboratory and field measures of aided performance were obtained to compare patient performance with the custom-fit and fixed-format hearing aids. In addition, coupler versus real-ear response differences were compared for the two hearing aid types. The results revealed that relatively close approximations to the real-ear aided responses of the custom-fit instruments were possible for most participants using seven fixed acoustic formats. No significant differences in mean performance between the two instrument types were observed for aided speech recognition or field ratings of aided performance, although mean patient satisfaction was lower for the disposable hearing aids. The real-ear to coupler difference was greater for the disposable hearing aid than for the custom-fit instruments, presumably owing to its deeper insertion into the ear canal.


2019 ◽  
Vol 28 (2) ◽  
pp. 274-284 ◽  
Author(s):  
Elizabeth Convery ◽  
Gitte Keidser ◽  
Louise Hickson ◽  
Carly Meyer

Purpose Hearing loss self-management refers to the knowledge and skills people use to manage the effects of hearing loss on all aspects of their daily lives. The purpose of this study was to investigate the relationship between self-reported hearing loss self-management and hearing aid benefit and satisfaction. Method Thirty-seven adults with hearing loss, all of whom were current users of bilateral hearing aids, participated in this observational study. The participants completed self-report inventories probing their hearing loss self-management and hearing aid benefit and satisfaction. Correlation analysis was used to investigate the relationship between individual domains of hearing loss self-management and hearing aid benefit and satisfaction. Results Participants who reported better self-management of the effects of their hearing loss on their emotional well-being and social participation were more likely to report less aided listening difficulty in noisy and reverberant environments and greater satisfaction with the effect of their hearing aids on their self-image. Participants who reported better self-management in the areas of adhering to treatment, participating in shared decision making, accessing services and resources, attending appointments, and monitoring for changes in their hearing and functional status were more likely to report greater satisfaction with the sound quality and performance of their hearing aids. Conclusion Study findings highlight the potential for using information about a patient's hearing loss self-management in different domains as part of clinical decision making and management planning.


2020 ◽  
Vol 29 (4) ◽  
pp. 738-761
Author(s):  
Tess K. Koerner ◽  
Melissa A. Papesh ◽  
Frederick J. Gallun

Purpose A questionnaire survey was conducted to collect information from clinical audiologists about rehabilitation options for adult patients who report significant auditory difficulties despite having normal or near-normal hearing sensitivity. This work aimed to provide more information about what audiologists are currently doing in the clinic to manage auditory difficulties in this patient population and their views on the efficacy of recommended rehabilitation methods. Method A questionnaire survey containing multiple-choice and open-ended questions was developed and disseminated online. Invitations to participate were delivered via e-mail listservs and through business cards provided at annual audiology conferences. All responses were anonymous at the time of data collection. Results Responses were collected from 209 participants. The majority of participants reported seeing at least one normal-hearing patient per month who reported significant communication difficulties. However, few respondents indicated that their location had specific protocols for the treatment of these patients. Counseling was reported as the most frequent rehabilitation method, but results revealed that audiologists across various work settings are also successfully starting to fit patients with mild-gain hearing aids. Responses indicated that patient compliance with computer-based auditory training methods was regarded as low, with patients generally preferring device-based rehabilitation options. Conclusions Results from this questionnaire survey strongly suggest that audiologists frequently see normal-hearing patients who report auditory difficulties, but that few clinicians are equipped with established protocols for diagnosis and management. While many feel that mild-gain hearing aids provide considerable benefit for these patients, very little research has been conducted to date to support the use of hearing aids or other rehabilitation options for this unique patient population. This study reveals the critical need for additional research to establish evidence-based practice guidelines that will empower clinicians to provide a high level of clinical care and effective rehabilitation strategies to these patients.


2020 ◽  
Vol 29 (3) ◽  
pp. 429-435
Author(s):  
Patricia C. Mancini ◽  
Richard S. Tyler ◽  
Hyung Jin Jun ◽  
Tang-Chuan Wang ◽  
Helena Ji ◽  
...  

Purpose The minimum masking level (MML) is the minimum intensity of a stimulus required to just totally mask the tinnitus. Treatments aimed at reducing the tinnitus itself should attempt to measure the magnitude of the tinnitus. The objective of this study was to evaluate the reliability of the MML. Method Sample consisted of 59 tinnitus patients who reported stable tinnitus. We obtained MML measures on two visits, separated by about 2–3 weeks. We used two noise types: speech-shaped noise and high-frequency emphasis noise. We also investigated the relationship between the MML and tinnitus loudness estimates and the Tinnitus Handicap Questionnaire (THQ). Results There were differences across the different noise types. The within-session standard deviation averaged across subjects varied between 1.3 and 1.8 dB. Across the two sessions, the Pearson correlation coefficients, range was r = .84. There was a weak relationship between the dB SL MML and loudness, and between the MML and the THQ. A moderate correlation ( r = .44) was found between the THQ and loudness estimates. Conclusions We conclude that the dB SL MML can be a reliable estimate of tinnitus magnitude, with expected standard deviations in trained subjects of about 1.5 dB. It appears that the dB SL MML and loudness estimates are not closely related.


1971 ◽  
Vol 36 (4) ◽  
pp. 527-537 ◽  
Author(s):  
Norman P. Erber

Two types of special hearing aid have been developed recently to improve the reception of speech by profoundly deaf children. In a different way, each special system provides greater low-frequency acoustic stimulation to deaf ears than does a conventional hearing aid. One of the devices extends the low-frequency limit of amplification; the other shifts high-frequency energy to a lower frequency range. In general, previous evaluations of these special hearing aids have obtained inconsistent or inconclusive results. This paper reviews most of the published research on the use of special hearing aids by deaf children, summarizes several unpublished studies, and suggests a set of guidelines for future evaluations of special and conventional amplification systems.