Performance of Cochlear Implant Patients as a Function of Time

1990 ◽  
Vol 33 (3) ◽  
pp. 511-519 ◽  
Author(s):  
Lynn G. Spivak ◽  
Susan B. Waltzman

The speech perception abilities of 15 patients were measured preoperatively using hearing aids and postoperatively using the Nucleus 22-channel cochlear implant over a period of 1, 2, or 3 years. Analysis of mean data revealed that, although the greatest amount of improvement in speech perception scores occurred between the preoperative and 3-month poststimulation evaluation, there was also significant improvement in perception of segmental features and open-set speech recognition over the 3-year time period. When individual patient data were examined, however, it was clear that these improvements were due, in large part, to the performance of a subset of patients who had measurable open-set speech recognition abilities at the time of their 3-month, poststimulation evaluation. Subjects who used the processing scheme that included coding of F1 showed significantly more improvement over time than subjects who used the original FOF2 processing scheme exclusively. It was concluded that open-set speech recognition ability at 3 months is an important prognostic indicator of continued improvement in speech perception abilities over time.

1998 ◽  
Vol 41 (5) ◽  
pp. 1073-1087 ◽  
Author(s):  
Aaron J. Parkinson ◽  
Wendy S. Parkinson ◽  
Richard S. Tyler ◽  
Mary W. Lowder ◽  
Bruce J. Gantz

Sixteen experienced cochlear implant patients with a wide range of speechperception abilities received the SPEAK processing strategy in the Nucleus Spectra-22 cochlear implant. Speech perception was assessed in quiet and in noise with SPEAK and with the patients' previous strategies (for most, Multipeak) at the study onset, as well as after using SPEAK for 6 months. Comparisons were made within and across the two test sessions to elucidate possible learning effects. Patients were also asked to rate the strategies on seven speech recognition and sound quality scales. After 6 months' experience with SPEAK, patients showed significantly improved mean performance on a range of speech recognition measures in quiet and noise. When mean subjective ratings were compared over time there were no significant differences noted between strategies. However, many individuals rated the SPEAK strategy better for two or more of the seven subjective measures. Ratings for "appreciation of music" and "quality of my own voice" in particular were generally higher for SPEAK. Improvements were realized by patients with a wide range of speech perception abilities, including those with little or no open-set speech recognition.


1992 ◽  
Vol 35 (4) ◽  
pp. 913-920 ◽  
Author(s):  
Holly Fryauf-Bertschy ◽  
Richard S. Tyler ◽  
Danielle M. Kelsay ◽  
Bruce J. Gantz

The speech perception performance of 10 congenitally deaf and 3 postlingually deafened children who received the Cochlear Corporation multichannel cochlear implant was examined and compared. The children were tested preimplant and at 6-month intervals up to 2 years using the Monosyllable-Trochee-Spondee test (MTS), the Word Intelligibility by Picture Identification test (WIPI), and Phonetically Balanced Kindergarten (PB-K) or Northwestern University List 6 (NU-6) word lists. The postlingually deafened children exhibited significantly improved performance on open- and closed-set tests of word recognition after 6 months of implant use, a pattern similar to that of postlingually deafened adult implant users. In contrast, the congenitally deaf children did not exhibit measurably improved performance on speech perception tests until after 12 months or more of implant use. With as much as 18–24 months of use, however, some congenitally deaf children demonstrated limited open-set word recognition.


2019 ◽  
Vol 30 (08) ◽  
pp. 703-711 ◽  
Author(s):  
Alissa Nickerson ◽  
Lisa S. Davidson ◽  
Rosalie M. Uchanski

AbstractAudibility of speech for children with hearing loss (HL) depends on the degree of HL and the fitting of the hearing aids (HAs) themselves. Many studies on cochlear implant (CI) users have demonstrated that preimplant hearing is associated with postimplant outcomes, but there have been very few reports on the fitting of HAs before surgery.The aims of this study were to characterize HA fittings and aided audibility of speech for pediatric HA users with severe to profound HL and to examine the relation between preimplant aided audibility and postimplant speech perception.A descriptive/observational and correlational study. Audiologic records of pediatric CI participants involved in a larger study examining the effects of early acoustic hearing were analyzed retrospectively; when available, these records included HA verification and speech recognition performance.The CI participants were enrolled in audiology centers and oral schools for the deaf across the United States.To determine whether deviations from prescribed DSL target were significantly greater than zero, 95% confidence intervals of the mean deviation were calculated for each frequency (250, 500, 1000, 2000, and 4000 Hz). Correlational analyses were used to examine the relationship between preimplant aided Speech Intelligibility Indices (SIIs) and postimplant speech perception in noise. Correlational analyses were also used to explore the relationship between preimplant aided SIIs and demographic data. T-tests were used to compare preimplant-aided SIIs of HAs of listeners who later became users of either sequential CIs, simultaneous CIs, or bimodal devices.Preimplant fittings of HAs were generally very close to prescriptive targets, except at 4000 Hz for those HAs with active frequency-lowering processing, and preimplant SIIs, albeit low, were correlated with postimplant speech recognition performance in noise. These results suggest that aided audibility should be maximized throughout the HA trial for later speech recognition purposes.It is recommended that HA fittings be optimized to support speech audibility even when considering implantation. In addition to the age at which HA use begins, the aided audibility itself is important in determining CI candidacy and decisions regarding bimodal HA use.


Author(s):  
Till F. Jakob ◽  
Iva Speck ◽  
Ann-Kathrin Rauch ◽  
Frederike Hassepass ◽  
Manuel C. Ketterer ◽  
...  

Abstract Purpose The aim of the study was to compare long-term results after 1 year in patients with single-sided deafness (SSD) who were fitted with different hearing aids. The participants tested contralateral routing of signals (CROS) hearing aids and bone-anchored hearing systems (BAHS). They were also informed about the possibility of a cochlear implant (CI) and chose one of the three devices. We also investigated which factors influenced the choice of device. Methods Prospective study with 89 SSD participants who were divided into three groups by choosing BAHS, CROS, or CI. All participants received test batteries with both objective hearing tests (speech perception in noise and sound localisation) and subjective questionnaires. Results 16 participants opted for BAHS-, 13 for CROS- and 30 for CI-treatment. The greater the subjective impairment caused by SSD, the more likely patients were to opt for surgical treatment (BAHS or CI). The best results in terms of speech perception in noise (especially when sound reaches the deaf ear and noise the hearing ear), sound localization, and subjective results were achieved with CI. Conclusion The best results regarding the therapy of SSD are achieved with a CI, followed by BAHS. This was evident both in objective tests and in the subjective questionnaires. Nevertheless, an individual decision is required in each case as to which SSD therapy option is best for the patient. Above all, the patient's subjective impairment and expectations should be included in the decision-making process.


2018 ◽  
Vol 23 (2) ◽  
pp. 89-97
Author(s):  
Nicolas Verhaert ◽  
Charlotte Borgers ◽  
Katleen De Voecht ◽  
Ellen Boon ◽  
Christian Desloovere

Recent findings support the efficacy of the direct acoustic cochlear implant (DACI) in patients with advanced otosclerosis whose rehabilitation is very challenging. Standard treatment consists of stapes surgery combined with hearing aids or a cochlear implant (CI). CI surgery, however, is often challenging depending on the grade of otosclerosis. This study aims to compare speech perception scores in quiet and noise of 6 DACI and 12 CI patients with advanced otosclerosis at 3 and 12 months after fitting. Preoperative computed tomographic scans of all patients were scored by experts using an existing otosclerosis grading system (stages 1–3). Speech perception in quiet was significantly better for DACI compared to CI users at 3 months after fitting. At 12 months, no difference was found between DACI and CI patients. Speech perception scores in noise were significantly better in the DACI group. In summary, a DACI system seems to provide an effective treatment option as the acoustic component can be preserved in patients with advanced otosclerosis.


2004 ◽  
Vol 5 (sup1) ◽  
pp. 128-130
Author(s):  
Min-Jung Heo ◽  
Lee-Suk Kim ◽  
Woo-Yong Bae ◽  
Young-Deok Park

2000 ◽  
Vol 56 (2) ◽  
pp. 101-111 ◽  
Author(s):  
Karen A. Gordon ◽  
Hamid Daya ◽  
Robert V. Harrison ◽  
Blake C. Papsin

2004 ◽  
Vol 1273 ◽  
pp. 223-226
Author(s):  
Jane R. Madell ◽  
Nicole Sislian ◽  
Ronald Hoffman

2010 ◽  
Vol 21 (07) ◽  
pp. 441-451 ◽  
Author(s):  
René H. Gifford ◽  
Lawrence J. Revit

Background: Although cochlear implant patients are achieving increasingly higher levels of performance, speech perception in noise continues to be problematic. The newest generations of implant speech processors are equipped with preprocessing and/or external accessories that are purported to improve listening in noise. Most speech perception measures in the clinical setting, however, do not provide a close approximation to real-world listening environments. Purpose: To assess speech perception for adult cochlear implant recipients in the presence of a realistic restaurant simulation generated by an eight-loudspeaker (R-SPACE™) array in order to determine whether commercially available preprocessing strategies and/or external accessories yield improved sentence recognition in noise. Research Design: Single-subject, repeated-measures design with two groups of participants: Advanced Bionics and Cochlear Corporation recipients. Study Sample: Thirty-four subjects, ranging in age from 18 to 90 yr (mean 54.5 yr), participated in this prospective study. Fourteen subjects were Advanced Bionics recipients, and 20 subjects were Cochlear Corporation recipients. Intervention: Speech reception thresholds (SRTs) in semidiffuse restaurant noise originating from an eight-loudspeaker array were assessed with the subjects' preferred listening programs as well as with the addition of either Beam™ preprocessing (Cochlear Corporation) or the T-Mic® accessory option (Advanced Bionics). Data Collection and Analysis: In Experiment 1, adaptive SRTs with the Hearing in Noise Test sentences were obtained for all 34 subjects. For Cochlear Corporation recipients, SRTs were obtained with their preferred everyday listening program as well as with the addition of Focus preprocessing. For Advanced Bionics recipients, SRTs were obtained with the integrated behind-the-ear (BTE) mic as well as with the T-Mic. Statistical analysis using a repeated-measures analysis of variance (ANOVA) evaluated the effects of the preprocessing strategy or external accessory in reducing the SRT in noise. In addition, a standard t-test was run to evaluate effectiveness across manufacturer for improving the SRT in noise. In Experiment 2, 16 of the 20 Cochlear Corporation subjects were reassessed obtaining an SRT in noise using the manufacturer-suggested “Everyday,” “Noise,” and “Focus” preprocessing strategies. A repeated-measures ANOVA was employed to assess the effects of preprocessing. Results: The primary findings were (i) both Noise and Focus preprocessing strategies (Cochlear Corporation) significantly improved the SRT in noise as compared to Everyday preprocessing, (ii) the T-Mic accessory option (Advanced Bionics) significantly improved the SRT as compared to the BTE mic, and (iii) Focus preprocessing and the T-Mic resulted in similar degrees of improvement that were not found to be significantly different from one another. Conclusion: Options available in current cochlear implant sound processors are able to significantly improve speech understanding in a realistic, semidiffuse noise with both Cochlear Corporation and Advanced Bionics systems. For Cochlear Corporation recipients, Focus preprocessing yields the best speech-recognition performance in a complex listening environment; however, it is recommended that Noise preprocessing be used as the new default for everyday listening environments to avoid the need for switching programs throughout the day. For Advanced Bionics recipients, the T-Mic offers significantly improved performance in noise and is recommended for everyday use in all listening environments.


2001 ◽  
Vol 44 (2) ◽  
pp. 264-285 ◽  
Author(s):  
Peter J. Blamey ◽  
Julia Z. Sarant ◽  
Louise E. Paatsch ◽  
Johanna G. Barry ◽  
Catherine P. Bow ◽  
...  

Eighty-seven primary-school children with impaired hearing were evaluated using speech perception, production, and language measures over a 3-year period. Forty-seven children with a mean unaided pure-tone-average hearing loss of 106 dB HL used a 22-electrode cochlear implant, and 40 with a mean unaided puretone-average hearing loss of 78 dB HL were fitted with hearing aids. All children were enrolled in oral/aural habilitation programs, and most attended integrated classes with normally hearing children for part of the time at school. Multiple linear regression was used to describe the relationships among the speech perception, production, and language measures, and the trends over time. Little difference in the level of performance and trends was found for the two groups of children, so the perceptual effect of the implant is equivalent, on average, to an improvement of about 28 dB in hearing thresholds. Scores on the Peabody Picture Vocabulary Test (PPVT) and the Clinical Evaluation of Language Fundamentals showed an upward trend at about 60% of the rate for normally hearing children. Rates of improvement for individual children were not correlated significantly with degree of hearing loss. The children showed a wide scatter about the average speech production score of 40% of words correctly produced in spontaneous conversations, with no significant upward trend with age. Scores on the open-set Consonant-Nucleus-Consonant (CNC) monosyllabic word test and the Bench-Kowal-Bamford (BKB) sentence test were strongly related to language level (as measured by an equivalent age on the PPVT) and speech production scores for both auditory-visual and auditory test conditions. After allowing for differences in language, speech perception scores in the auditory test condition showed a slight downward trend over time, which is consistent with the known biological effects of hearing loss on the auditory periphery and brainstem. Speech perception scores in the auditory condition also decreased significantly by about 5% for every 10 dB of hearing loss in the hearing aid group. The regression analysis model allows separation of the effects of language, speech production, and hearing levels on speech perception scores so that the effects of habilitation and training in these areas can be observed and/or predicted. The model suggests that most of the children in the study will reach a level of over 90% sentence recognition in the auditory-visual condition when their language becomes equivalent to that of a normally hearing 7-year-old, but they will enter secondary school at age 12 with an average language delay of about 4 or 5 years unless they receive concentrated and effective language training.


Sign in / Sign up

Export Citation Format

Share Document