Acoustic Characteristics of Speech Produced Without Oral Sensation

1973 ◽  
Vol 16 (1) ◽  
pp. 67-77 ◽  
Author(s):  
Yoshiyuki Horii ◽  
Arthur S. House ◽  
Kung-Pu Li ◽  
Robert L. Ringel

The acoustic characteristics of continuous speech produced by an adult male talker with and without oral (nerve block) anesthesia were investigated using digital speech processing procedures. Vowel-to-consonant ratios, long-time and short-time spectra, fundamental frequency distributions, phonation-time ratios, and rate of utterances were calculated and compared for the normal and anesthetized conditions. The results showed that the speech produced without oral sensation was characterized by a reduction and shift of high-frequency energy, temporal disorganization primarily manifested as prolongation of utterance, and higher and more variable fundamental frequencies. The study also demonstrated applicability of computer techniques on general acoustic analysis of continuous speech.

1990 ◽  
Vol 20 (1) ◽  
pp. 15-21 ◽  
Author(s):  
Peter Roach ◽  
Helen Roach ◽  
Andrea Dew ◽  
Paul Rowlands

A fundamentally important practice in phonetics is the analysis of continuous speech into a sequence of discrete segments. There has been considerable debate about the theoretical validity of this practice within classical auditory/kinaesthetic phonetics and in phonology as well as in the context of the acoustic analysis of speech; in recent years the issue has become more widely important as research work in automatic speech processing has resulted in computer algorithms for segmenting speech and assigning phonetic labels to the segments. Work on the automatic segmentation and labeling of speech sounds has been carried on in our department since 1980. This paper begins by examining the theoretical issues involved in segmentation and labeling, then describes our own work.


Author(s):  
Ghanshyam Rai

<div><p><em>A high-power Gaussian Whistler propagating in a magnatoplasma becomes self-focused because of (i) ponderomotive force and (ii) nonuniform heating nonlinearities (i) being dominant for t &lt;&lt; T and (ii) being dominant for t &gt; t<sub>E</sub>. On short time scale (t &lt;&lt; t<sub>E</sub> ) whistlers of all frequencies can be focused (the self – focusing length is very large for ω= </em><em> /2 and decreases rapidly on both sides), whereas on the long time scale (t &gt; t<sub>E</sub>) only high frequency whistlers (ω&gt; </em><em> /2) are focused. At very high powers the plasma is depleted almost completely from the axial region and self-focusing does not occur, rather, defocusing takes place. </em></p><p><em>            A plane uniform whistler of high intensity is seen to be unstable for small scale fluctuations, i.e., it must break up into filaments in course of it propagation. The growth rate increases with decreasing scale length of perturbation and is seen to be a saturating function of power density of the beam. </em></p></div>


2012 ◽  
Vol 588-589 ◽  
pp. 1539-1542
Author(s):  
Min Gang Wang ◽  
Yu Ting Liu ◽  
Wei Li ◽  
Yao Yang

Bellows is a thin-walled metal cylindrical with folds, as a pipeline connection and compensation device, it has the feature such as reliable and compact. Now Bellows is widely used in the produce of aerospace engines and the relative industries. In order to solve the load life test problem of bellows, the squeezing and twisting process after the long time loading is simulated by swinging and pressing it rapidly in a short time. Adopting NI Real-Time Hypervisor,a real-time monitor and test system is built by Windows operation system. According to the real twist data of bellows,the dynamic equation of swing platform for two cylinder is constructed, by the real-time and a high precsion control of the motion of two cylinders, the bellows which is full of liquid has been squeezed and twisted with a high frequency, and loading test of the mechanical properties, strength and lifetime for bellows is achieved in an automatic way.


2019 ◽  
Vol 27 (3) ◽  
pp. 157
Author(s):  
A. Orihuela ◽  
R. Ungerfeld

Vocalisations can be used as reliable indicators of pain, but little information is available in rabbits, where acoustic tools for farming environments can be used for welfare judgements. The aim of this study was to compare vocalisations produced during copula ejaculation and electro-ejaculation (EE), with or without general anaesthesia, in domestic rabbits. Vocalisations of nine New Zealand white adult males were digitally recorded. The number of males vocalising and vocal characteristics including high, low, maximum and fundamental frequencies and duration of the vocalisations were analysed. There were no differences in the number of males vocalising or any vocalisation parameter between the 1<sup>st</sup> and 2<sup>nd</sup> ejaculation while copulating, even though the fundamental frequency increased in all males in the 2<sup>nd</sup> ejaculation (<em>P</em>=0.008). More males vocalised while mating than while being electro-ejaculated (<em>P</em>=0.03), and all vocalisation parameters were greater during EE than while mating (<em>P</em>=0.004). The use or not of anaesthesia during EE did not modify any of the parameters evaluated. It was concluded that: 1) more males vocalised during copula ejaculation than while being electro-ejaculated; 2) bio-acoustic analysis allowed us to identify aversive utterance vocalisations, which are characterised with higher frequencies, that those from non-aversive stimulus; and 3) at least with the anaesthetic combination and the responses studied, anaesthesia had no effect on the acoustic characteristics of the vocalisation emitted during EE in rabbits.


1923 ◽  
Vol 128 (4) ◽  
pp. 264-264
Author(s):  
J. W. Harsch
Keyword(s):  

Author(s):  
Kenji Ikeda ◽  
Yusuke Kawamura ◽  
Masahiro Kobayashi ◽  
Taito Fukushima ◽  
Yushi Sorin ◽  
...  

Background: Although DC Bead has been useful in treatment of multiple and large hepatocellular carcinoma, loading time of doxorubicin into the DC Bead takes a long time of 30-120 minutes. Epirubicin is also used as an antitumor agent together with DC Bead, but its loading efficiency was not sufficiently elucidated. Methods: To shorten loading time of epirubicin into DC Bead (100-300µm, 300-500µm, 500-700µm), we examined the following three methods after mixing the drug: (a) let stand in room temperature, (b) agitated for 30 seconds with Vortex mixer, and (c) sonicated for 30 seconds with ultrasonic cleaner. After loading of epirubicin by each method, supernatant concentration for epirubicin was assayed at 5, 10, 30, 60, and 120 minutes. Results: Epirubicin loading rates for small bead (100-300µm) at 5 minutes were 82.9 % in group a, 93.8% in group b, and 79.9 % in group c. Similarly, medium bead (300-500µm), 40.1% in group a, 65.7% in group b and 45.5% in group c, respectively. In large-sized bead (500-700µm), loaded rates of epirubicin were 38.8% in group a, 59.0% in group b and 48.0% in group c. Agitation of mixture of epirubicin and DC Bead with Vortex mixer significantly shortened the loading time, but sonication did not affect the time required. Microscopic examination did not lead to any morphological change of microspheres in all the methods. Conclusions: Short time of agitation with Vortex mixer reduced the necessary time for loading of epirubicin in every standard of DC Bead.


Author(s):  
Yasunobu Iwai ◽  
Koichi Shinozaki ◽  
Daiki Tanaka

Abstract Compared with space parts, consumer parts are highly functional, low cost, compact and lightweight. Therefore, their increased usage in space applications is expected. Prior testing and evaluation on space applicability are necessary because consumer parts do not have quality guarantees for space application [1]. However, in the conventional reliability evaluation method, the test takes a long time, and the problem is that the robustness of the target sample can’t be evaluated in a short time. In this report, we apply to the latest TSOP PEM (Thin Small Outline Package Plastic Encapsulated Microcircuit) an evaluation method that combines preconditioning and HALT (Highly Accelerated Limit Test), which is a test method that causes failures in a short time under very severe environmental conditions. We show that this method can evaluate the robustness of TSOP PEMs including solder connections in a short time. In addition, the validity of this evaluation method for TSOP PEM is shown by comparing with the evaluation results of thermal shock test and life test, which are conventional reliability evaluation methods.


2020 ◽  
Vol 44 (3) ◽  
pp. 241-249
Author(s):  
Yoshiaki Omura

While a visiting Professor at the University of Paris, VI (formerly Sorvonne) more than 40 years ago, the Author became very good friends with Dr. Paul Nogier who periodically gave seminars and workshops in Paris. After the author diagnosed his cervical problem & offered him simple help, Dr. Nogier asked the Author to present lectures and demonstrations on the effects of ear stimulation, namely the effects of acupuncture & electrical stimulation of the ear lobules. It is only now, in 2019 that we have discovered 2–5 minute high frequency stimulation of the ear lobule inhibits cancer activity for 1– 4 hours post stimulation. Although the procedure is extremely simple. First take optimal dose of Vitamin D3, which has the most essential 10 unique beneficial factors required for every human cell activity. Next, apply high frequency stimulation to ear lobule while the worst ear lobule is held by all fingers with vibrator directly touching the surface of the worst ear lobule, preferably after patient repeatedly takes optimal dose of Vitamin D3. When the worst ear lobule is held between thumb & index fingers and applying mechanical stimulation of 250 ~ 500 mechanical vibration/second for 2 ~ 5 minutes using an electrical vibrator, there is rapid disappearance of cancer activity in both the brain and rest of the body for short time duration 1 ~ 4 hours. The effect often increases by additional pressure by holding fingers. As of May 2019, the Author found that many people from various regions of the world developed early stages of multiple cancers. For evaluation of this study, U. S. patented Bi-Digital O-Ring Test (BDORT) was used which was developed by the Author while doing his Graduate experimental physics research at Colombia University. BDORT was found to be most essential for determining the beneficial effects as well as harmful effects of any substance or treatment. Using BDORT, Author was the first to recognize severe increasing mid-backache was an early sign of pancreatic cancer of President of New York State Board of Medicine after top pain specialists failed to detect the cause after 3 years of effort, while the BDORT showed early stages of cancer whereas conventional X-Ray of the pancreas did not show any cancer image until 2 months after Author detected with BDORT. For example, the optimal dose of the banana is usually about 2.0 - 2.5 millimeters cross section of the banana. A whole banana is more than 50 ~ 100 times the optimal dose. Any substance eaten in more than 25 times of its optimal dose becomes highly toxic and creates DNA mutations which can cause multiple malignancies in the presence of strong electro-magnetic field. With standard medication given by doctor, patients often become sick and they are unable to reduce body weight, unless medication is reduced or completely stopped. When the amount of zinc is very high, DNA often becomes unstable and multiple cancers can grow rapidly in the presence of strong electromagnetic field. Large amount of Vitamin C from regular orange or orange juice inhibit the most important Vitamin D3 effects. At least 3 kinds of low Vitamin C oranges will not inhibit Vitamin D3. Since B12 particularly methyl cobalamin which is a red small tablet is known to improve brain circulation very significantly we examined its effect within 20 seconds of oral intake we found the following very significant changes. Acetylcholine in both sides of the brain often increases over 4,500 ng. Longevity gene Sirtuin 1 level increases significantly for short time of few hours. Thymosin α1 and Thymosinβ4 both increase to over 1500 ng from 20 ng or less.


1984 ◽  
Vol 16 (3-4) ◽  
pp. 623-633
Author(s):  
M Loxham ◽  
F Weststrate

It is generally agreed that both the landfill option, or the civil techniques option for the final disposal of contaminated harbour sludge involves the isolation of the sludge from the environment. For short time scales, engineered barriers such as a bentonite screen, plastic sheets, pumping strategies etc. can be used. However for long time scales the effectiveness of such measures cannot be counted upon. It is thus necessary to be able to predict the long term environmenttal spread of contaminants from a mature landfill. A model is presented that considers diffusion and adsorption in the landfill site and convection and adsorption in the underlaying aquifer. From a parameter analysis starting form practical values it is shown that the adsorption behaviour and the molecular diffusion coefficient of the sludge, are the key parameters involved in the near field. The dilution effects of the far field migration patterns are also illustrated.


2021 ◽  
pp. 074823372110226
Author(s):  
Gholamali Jelodar ◽  
Mansour Azimzadeh ◽  
Fatemeh Radmard ◽  
Narges Darvishhoo

Exposure to mobile phone radiation causes deleterious health effects on biological systems. The objects of this study were to investigate the effect of 900-MHz radiofrequency waves (RFW) emitted from base transceiver station antenna on intrapancreatic homocysteine (Hcy), tumor necrosis factor-α (TNF-α), and nerve growth factor (NGF) as predisposing factors involved in pancreatic beta cell damage. Thirty male rats (Sprague-Dawley, 200 ± 10 g) were randomly divided into the control (without any exposure) and exposed groups: short time (2 h/day), long time (4 h/day), and exposed to 900-MHz RFW for 30 consecutive days. On the last days of the experiment, animals were killed and pancreas tissue was dissected out for evaluation of serotonin, Hcy, TNF-α, and NGF. There was a significant decrease in the serotonin and NGF levels in the pancreatic tissue of exposed groups compared to the control group ( p < 0.05). Also, the levels of serotonin and NGF in the long-time exposure were significantly lower than the short-time exposure ( p < 0.05). However, levels of Hcy and TNF-α were significantly increased in the pancreas of exposed groups compared to the control groups ( p < 0.05). Exposure to 900-MHz RFW decreased pancreatic NGF and serotonin levels and increased the proinflammatory markers (Hcy and TNF-α), which can be a predisposing factor for type 2 diabetes.


Sign in / Sign up

Export Citation Format

Share Document