scholarly journals A beginner's guide to flow kinetics

2020 ◽  
Vol 42 (2) ◽  
pp. 40-44
Author(s):  
Clive R. Bagshaw

For a liquid flowing through a tube at constant velocity, the distance from the point of origin can provide a measure of the reaction time. This concept of continuous flow, first applied over a century ago to follow biochemical reactions by absorption spectroscopy, is now being used in conjunction with high-resolution structural methods such as X-ray crystallography and cryo-electron microscopy. The resultant kinetic information is crucial to understanding the mechanism.

Author(s):  
Catherine Vénien-Bryan ◽  
Zhuolun Li ◽  
Laurent Vuillard ◽  
Jean Albert Boutin

The invention of the electron microscope has greatly enhanced the view scientists have of small structural details. Since its implementation, this technology has undergone considerable evolution and the resolution that can be obtained for biological objects has been extended. In addition, the latest generation of cryo-electron microscopes equipped with direct electron detectors and software for the automated collection of images, in combination with the use of advanced image-analysis methods, has dramatically improved the performance of this technique in terms of resolution. While calculating a sub-10 Å resolution structure was an accomplishment less than a decade ago, it is now common to generate structures at sub-5 Å resolution and even better. It is becoming possible to relatively quickly obtain high-resolution structures of biological molecules, in particular large ones (>500 kDa) which, in some cases, have resisted more conventional methods such as X-ray crystallography or nuclear magnetic resonance (NMR). Such newly resolved structures may, for the first time, shed light on the precise mechanisms that are essential for cellular physiological processes. The ability to attain atomic resolution may support the development of new drugs that target these proteins, allowing medicinal chemists to understand the intimacy of the relationship between their molecules and targets. In addition, recent developments in cryo-electron microscopy combined with image analysis can provide unique information on the conformational variability of macromolecular complexes. Conformational flexibility of macromolecular complexes can be investigated using cryo-electron microscopy and multiconformation reconstruction methods. However, the biochemical quality of the sample remains the major bottleneck to routine cryo-electron microscopy-based determination of structures at very high resolution.


IUCrJ ◽  
2018 ◽  
Vol 5 (4) ◽  
pp. 382-389 ◽  
Author(s):  
Lingxiao Zeng ◽  
Wei Ding ◽  
Quan Hao

X-ray crystallography and cryo-electron microscopy (cryo-EM) are complementary techniques for structure determination. Crystallography usually reveals more detailed information, while cryo-EM is an extremely useful technique for studying large-sized macromolecules. As the gap between the resolution of crystallography and cryo-EM data narrows, the cryo-EM map of a macromolecule could serve as an initial model to solve the phase problem of crystal diffraction for high-resolution structure determination. FSEARCH is a procedure to utilize the low-resolution molecular shape for crystallographic phasing. The IPCAS (Iterative Protein Crystal structure Automatic Solution) pipeline is an automatic direct-methods-aided dual-space iterative phasing and model-building procedure. When only an electron-density map is available as the starting point, IPCAS is capable of generating a completed model from the phases of the input map automatically, without the requirement of an initial model. In this study, a hybrid method integrating X-ray crystallography with cryo-EM to help with structure determination is presented. With a cryo-EM map as the starting point, the workflow of the method involves three steps. (1) Cryo-EM map replacement: FSEARCH is utilized to find the correct translation and orientation of the cryo-EM map in the crystallographic unit cell and generates the initial low-resolution map. (2) Phase extension: the phases calculated from the correctly placed cryo-EM map are extended to high-resolution X-ray data by non-crystallographic symmetry averaging with phenix.resolve. (3) Model building: IPCAS is used to generate an initial model using the phase-extended map and perform model completion by iteration. Four cases (the lowest cryo-EM map resolution being 6.9 Å) have been tested for the general applicability of the hybrid method, and almost complete models have been generated for all test cases with reasonable R work/R free. The hybrid method therefore provides an automated tool for X-ray structure determination using a cryo-EM map as the starting point.


Author(s):  
Robert A. Grant ◽  
Laura L. Degn ◽  
Wah Chiu ◽  
John Robinson

Proteolytic digestion of the immunoglobulin IgG with papain cleaves the molecule into an antigen binding fragment, Fab, and a compliment binding fragment, Fc. Structures of intact immunoglobulin, Fab and Fc from various sources have been solved by X-ray crystallography. Rabbit Fc can be crystallized as thin platelets suitable for high resolution electron microscopy. The structure of rabbit Fc can be expected to be similar to the known structure of human Fc, making it an ideal specimen for comparing the X-ray and electron crystallographic techniques and for the application of the molecular replacement technique to electron crystallography. Thin protein crystals embedded in ice diffract to high resolution. A low resolution image of a frozen, hydrated crystal can be expected to have a better contrast than a glucose embedded crystal due to the larger density difference between protein and ice compared to protein and glucose. For these reasons we are using an ice embedding technique to prepare the rabbit Fc crystals for molecular structure analysis by electron microscopy.


2020 ◽  
Vol 76 (1) ◽  
pp. 63-72
Author(s):  
Lingxiao Zeng ◽  
Wei Ding ◽  
Quan Hao

The combination of cryo-electron microscopy (cryo-EM) and X-ray crystallography reflects an important trend in structural biology. In a previously published study, a hybrid method for the determination of X-ray structures using initial phases provided by the corresponding parts of cryo-EM maps was presented. However, if the target structure of X-ray crystallography is not identical but homologous to the corresponding molecular model of the cryo-EM map, then the decrease in the accuracy of the starting phases makes the whole process more difficult. Here, a modified hybrid method is presented to handle such cases. The whole process includes three steps: cryo-EM map replacement, phase extension by NCS averaging and dual-space iterative model building. When the resolution gap between the cryo-EM and X-ray crystallographic data is large and the sequence identity is low, an intermediate stage of model building is necessary. Six test cases have been studied with sequence identity between the corresponding molecules in the cryo-EM and X-ray structures ranging from 34 to 52% and with sequence similarity ranging from 86 to 91%. This hybrid method consistently produced models with reasonable R work and R free values which agree well with the previously determined X-ray structures for all test cases, thus indicating the general applicability of the method for X-ray structure determination of homologues using cryo-EM maps as a starting point.


PLoS ONE ◽  
2016 ◽  
Vol 11 (1) ◽  
pp. e0146457 ◽  
Author(s):  
Noella Silva-Martin ◽  
María I. Daudén ◽  
Sebastian Glatt ◽  
Niklas A. Hoffmann ◽  
Panagiotis Kastritis ◽  
...  

2018 ◽  
Vol 74 (a1) ◽  
pp. a224-a224
Author(s):  
Jason Key ◽  
Peter A. Meyer ◽  
Carol Herre ◽  
Michael Timony ◽  
Dimitry Filonov ◽  
...  

2021 ◽  
Vol 9 (1) ◽  
pp. 5-20
Author(s):  
Vittoria Raimondi ◽  
◽  
Alessandro Grinzato ◽  
◽  

<abstract> <p>In the last years, cryogenic-electron microscopy (cryo-EM) underwent the most impressive improvement compared to other techniques used in structural biology, such as X-ray crystallography and NMR. Electron microscopy was invented nearly one century ago but, up to the beginning of the last decades, the 3D maps produced through this technique were poorly detailed, justifying the term “blobbology” to appeal to cryo-EM. Recently, thanks to a new generation of microscopes and detectors, more efficient algorithms, and easier access to computational power, single particles cryo-EM can routinely produce 3D structures at resolutions comparable to those obtained with X-ray crystallography. However, unlike X-ray crystallography, which needs crystallized proteins, cryo-EM exploits purified samples in solution, allowing the study of proteins and protein complexes that are hard or even impossible to crystallize. For these reasons, single-particle cryo-EM is often the first choice of structural biologists today. Nevertheless, before starting a cryo-EM experiment, many drawbacks and limitations must be considered. Moreover, in practice, the process between the purified sample and the final structure could be trickier than initially expected. Based on these observations, this review aims to offer an overview of the principal technical aspects and setups to be considered while planning and performing a cryo-EM experiment.</p> </abstract>


2019 ◽  
Author(s):  
Vanja Stojković ◽  
Alexander G. Myasnikov ◽  
Iris D. Young ◽  
Adam Frost ◽  
James S. Fraser ◽  
...  

ABSTRACTPost-transcriptional ribosomal RNA (rRNA) modifications are present in all organisms, but their exact functional roles and positions are yet to be fully characterized. Modified nucleotides have been implicated in the stabilization of RNA structure and regulation of ribosome biogenesis and protein synthesis. In some instances, rRNA modifications can confer antibiotic resistance. High-resolution ribosome structures are thus necessary for precise determination of modified nucleotides’ positions, a task that has previously been accomplished by X-ray crystallography. Here we present a cryo-electron microscopy (cryo-EM) structure of Escherichia coli (E. coli) 50S subunit at an average resolution of 2.2Å as an additional approach for mapping modification sites. Our structure confirms known modifications present in 23S rRNA and additionally allows for localization of Mg2+ ions and their coordinated water molecules. Using our cryo-EM structure as a testbed, we developed a program for identification of post-transcriptional rRNA modifications using a cryo-EM map. This program can be easily used on any RNA-containing cryo-EM structure, and an associated Coot plugin allows for visualization of validated modifications, making it highly accessible.


Sign in / Sign up

Export Citation Format

Share Document