Adhesive and tough hydrogels: From structural design to applications

Author(s):  
Wanglong Zhang ◽  
Yiwei Zhang ◽  
Yuchen Zhang ◽  
Yu Dai ◽  
Fan Xia ◽  
...  

In recent years, multifunctional hydrogels have aroused great interest. Usually, there is a contradiction between the toughness and interface adhesion of traditional hydrogels. In engineering and medical applications, hydrogels need...

1976 ◽  
Vol 15 (02) ◽  
pp. 69-74
Author(s):  
M. Goldberg ◽  
B. Doyon

This paper describes a general data base management package, devoted to medical applications. SARI is a user-oriented system, able to take into account applications very different by their nature, structure, size, operating procedures and general objectives, without any specific programming. It can be used in conversational mode by users with no previous knowledge of computers, such as physicians or medical clerks.As medical data are often personal data, the privacy problem is emphasized and a satisfactory solution implemented in SARI.The basic principles of the data base and program organization are described ; specific efforts have been made in order to increase compactness and to make maintenance easy.Several medical applications are now operational with SARI. The next steps will mainly consist in the implementation of highly sophisticated functions.


2011 ◽  
Vol 131 (3) ◽  
pp. 275-282
Author(s):  
Kenta Seki ◽  
Hiroaki Matsuura ◽  
Makoto Iwasaki ◽  
Hiromu Hirai ◽  
Soichi Tohyama

PCI Journal ◽  
1965 ◽  
Vol 10 (1) ◽  
pp. 91-94
Author(s):  
Felix Kulka

2020 ◽  
Vol 15 (1) ◽  
pp. 37-44
Author(s):  
El Mehdi Echebba ◽  
Hasnae Boubel ◽  
Oumnia Elmrabet ◽  
Mohamed Rougui

Abstract In this paper, an evaluation was tried for the impact of structural design on structural response. Several situations are foreseen as the possibilities of changing the distribution of the structural elements (sails, columns, etc.), the width of the structure and the number of floors indicates the adapted type of bracing for a given structure by referring only to its Geometric dimensions. This was done by studying the effect of the technical design of the building on the natural frequency of the structure with the study of the influence of the distribution of the structural elements on the seismic response of the building, taking into account of the requirements of the Moroccan earthquake regulations 2000/2011 and using the ANSYS APDL and Robot Structural Analysis software.


Sign in / Sign up

Export Citation Format

Share Document