Non-invasive analysis of pancreas organoids in synthetic hydrogels defines material-cell interactions and luminal composition

2021 ◽  
Author(s):  
Nathalie Jung ◽  
Till Moreth ◽  
Ernst H.K. Stelzer ◽  
Francesco Pampaloni ◽  
Maike Windbergs

The cultivation of cells forming three-dimensional structures like organoids holds great potential in different fields of life sciences and is gaining increasing interest with regards to clinical applications and personalised...

Author(s):  
Serguei Semenov

Microwave tomography (MWT) is an emerging biomedical imaging modality with great potential for non-invasive assessment of functional and pathological conditions of soft tissues. This paper presents a review of research results obtained by the author and his colleagues and focuses on various potential clinical applications of MWT. Most clinical applications of MWT imaging have complicated, nonlinear, high dielectric contrast inverse problems of three-dimensional diffraction tomography. There is a very high dielectric contrast between bones and fatty areas compared with soft tissues. In most cases, the contrast between soft-tissue abnormalities (the target imaging areas) is less pronounced than between bone (fat) and soft tissue. This additionally complicates the imaging problem. In spite of the difficulties mentioned, it has been demonstrated that MWT is applicable for extremities imaging, breast cancer detection, diagnostics of lung cancer, brain imaging and cardiac imaging.


Author(s):  
H.W. Deckman ◽  
B.F. Flannery ◽  
J.H. Dunsmuir ◽  
K.D' Amico

We have developed a new X-ray microscope which produces complete three dimensional images of samples. The microscope operates by performing X-ray tomography with unprecedented resolution. Tomography is a non-invasive imaging technique that creates maps of the internal structure of samples from measurement of the attenuation of penetrating radiation. As conventionally practiced in medical Computed Tomography (CT), radiologists produce maps of bone and tissue structure in several planar sections that reveal features with 1mm resolution and 1% contrast. Microtomography extends the capability of CT in several ways. First, the resolution which approaches one micron, is one thousand times higher than that of the medical CT. Second, our approach acquires and analyses the data in a panoramic imaging format that directly produces three-dimensional maps in a series of contiguous stacked planes. Typical maps available today consist of three hundred planar sections each containing 512x512 pixels. Finally, and perhaps of most import scientifically, microtomography using a synchrotron X-ray source, allows us to generate maps of individual element.


2018 ◽  
Vol 13 (2) ◽  
pp. 187-211
Author(s):  
Patricia E. Chu

The Paris avant-garde milieu from which both Cirque Calder/Calder's Circus and Painlevé’s early films emerged was a cultural intersection of art and the twentieth-century life sciences. In turning to the style of current scientific journals, the Paris surrealists can be understood as engaging the (life) sciences not simply as a provider of normative categories of materiality to be dismissed, but as a companion in apprehending the “reality” of a world beneath the surface just as real as the one visible to the naked eye. I will focus in this essay on two modernist practices in new media in the context of the history of the life sciences: Jean Painlevé’s (1902–1989) science films and Alexander Calder's (1898–1976) work in three-dimensional moving art and performance—the Circus. In analyzing Painlevé’s work, I discuss it as exemplary of a moment when life sciences and avant-garde technical methods and philosophies created each other rather than being classified as separate categories of epistemological work. In moving from Painlevé’s films to Alexander Calder's Circus, Painlevé’s cinematography remains at the forefront; I use his film of one of Calder's performances of the Circus, a collaboration the men had taken two decades to complete. Painlevé’s depiction allows us to see the elements of Calder's work that mark it as akin to Painlevé’s own interest in a modern experimental organicism as central to the so-called machine-age. Calder's work can be understood as similarly developing an avant-garde practice along the line between the bestiary of the natural historian and the bestiary of the modern life scientist.


2012 ◽  
Vol 153 (40) ◽  
pp. 1570-1577 ◽  
Author(s):  
Attila Nemes ◽  
Anita Kalapos ◽  
Péter Domsik ◽  
Tamás Forster

Three-dimensional speckle-tracking echocardiography is a new cardiac imaging methodology, which allows three-dimensional non-invasive evaluation of the myocardial mechanics. The aim of this review is to present this new tool emphasizing its diagnostic potentials and demonstrating its limitations, as well. Orv. Hetil., 2012, 153, 1570–1577.


2015 ◽  
Vol 11 (1) ◽  
pp. 2897-2908
Author(s):  
Mohammed S.Aljohani

Tomography is a non-invasive, non-intrusive imaging technique allowing the visualization of phase dynamics in industrial and biological processes. This article reviews progress in Electrical Capacitance Volume Tomography (ECVT). ECVT is a direct 3D visualizing technique, unlike three-dimensional imaging, which is based on stacking 2D images to obtain an interpolated 3D image. ECVT has recently matured for real time, non-invasive 3-D monitoring of processes involving materials with strong contrast in dielectric permittivity. In this article, ECVT sensor design, optimization and performance of various sensors seen in literature are summarized. Qualitative Analysis of ECVT image reconstruction techniques has also been presented.


Heliyon ◽  
2021 ◽  
Vol 7 (4) ◽  
pp. e06645
Author(s):  
Charlotte Theresa Trebing ◽  
Sinan Sen ◽  
Stefan Rues ◽  
Christopher Herpel ◽  
Maria Schöllhorn ◽  
...  

Author(s):  
L Epprecht ◽  
L Qingsong ◽  
N Stenz ◽  
S Hashimi ◽  
T Linder

Abstract Objective Ventilation of the middle ear and mastoid air cells is believed to play an important role in the pathogenesis of chronic ear disease. Traditionally, ventilation is assessed by computed tomography. However, this exposes patients to cumulative radiation injury. In cases with a perforation in the tympanic membrane, tympanometry potentially presents a non-invasive alternative to measure the ventilated middle-ear and mastoid air cell volume. This study hypothesised that total tympanometry volume correlates with ventilated middle-ear and mastoid air cell volume. Method Total tympanometry volume was compared with ventilated middle-ear and mastoid air cell volume on computed tomography scans in 20 tympanic membrane perforations. Results There was a high correlation between tympanometry and computed tomography volumes (r = 0.78; p < 0.001). A tympanometry volume more than 2 ml predicted good ventilation on computed tomography. Conclusion These results may help reduce the need for pre-operative computed tomography in uncomplicated cases with tympanic membrane perforations.


2021 ◽  
Vol 8 (1) ◽  
Author(s):  
Mario Manto ◽  
Shinji Kakei ◽  
Hiroshi Mitoma

AbstractNon-invasive cerebellar stimulation (NICS) aims to modulate cerebello-cerebral loops and cerebro-spinal loops, both for research and clinical applications. It is of paramount importance to establish and validate morphological and functional tools to quantify cerebellar reserve, defined as the capacity for restoration and compensation to pathology of the cerebellum. Using NICS without efforts to estimate cerebellar reserve will end up in conflicting results due to the very high heterogeneity of cerebellar disorders encountered in daily practice.


2020 ◽  
Vol 10 (23) ◽  
pp. 8563
Author(s):  
Sangmo Koo

Two-photon polymerization (TPP) based on the femtosecond laser (fs laser) direct writing technique in the realization of high-resolution three-dimensional (3D) shapes is spotlighted as a unique and promising processing technique. It is also interesting that TPP can be applied to various applications in not only optics, chemistry, physics, biomedical engineering, and microfluidics but also micro-robotics systems. Effort has been made to design innovative microscale actuators, and research on how to remotely manipulate actuators is also constantly being conducted. Various manipulation methods have been devised including the magnetic, optical, and acoustic control of microscale actuators, demonstrating the great potential for non-contact and non-invasive control. However, research related to the precise control of microscale actuators is still in the early stages, and in-depth research is needed for the efficient control and diversification of a range of applications. In the future, the combination of the fs laser-based fabrication technique for the precise fabrication of microscale actuators/robots and their manipulation can be established as a next-generation processing method by presenting the possibility of applications to various areas.


2020 ◽  
Vol 65 (4) ◽  
pp. 477-484
Author(s):  
Christoph Thorwächter ◽  
Matthias Woiczinski ◽  
Inês Santos ◽  
Florian Schmidutz ◽  
Alexander Paulus ◽  
...  

AbstractThreaded cups show good clinical results when implanted correctly. In clinical use, multiple cases with an incomplete placement of the EcoFit threaded cup (implantcast) were observed. This behaviour could not be explained intra- and postoperatively. The aim of this study was to compare and optimise the drill-in-behaviour of the EcoFit cup in a biomechanical investigation. EcoFit cup sizes 46, 50 and 54 mm were compared with the SC cup (Aesculap) size 50 mm. Foam blocks (Sawbones) of density 0.16 g/ml (pcf 10), 0.32 g/ml (pcf 20) and 0.48 g/ml (pcf 30) were used. After standardised placement using a universal testing system (n = 8 per group), the primary stability, the overhang of the cups and the drill-in behaviour were measured. Overreamings of 1 and 2 mm were performed (pcf 20, n = 8) for the EcoFit cup size 50 and the primary stability as well as the overhang measurements were examined. Measurements of the cup diameter, thread depth and thread pitch were performed on three-dimensional (3D) images of the cup size 50 mm. The drill-in behaviour was different between the EcoFit and the SC cups. Even with maximum torque, the EcoFit cup could not be positioned as deep as the SC cup in standard reaming conditions (overhang of 1.1 ± 0.4 mm for the EcoFit size 50 in pcf 20 and of −0.01 ± 0.2 mm for the SC cup). The primary stability was lower for the EcoFit cup in comparison to the SC cup (128.8 ± 3.2 Nm vs. 138.6 ± 9.1 Nm, p = 0.0291). With overreaming to 51 mm, a deeper positioning of the EcoFit was possible (overlap of −0.3 ± 0.1, comparable to the SC cup). The overreaming of the cavity also led to a significantly higher primary stability of 143.4 ± 3.7 Nm (p < 0.001) comparable to the unaltered condition (128.8 ± 3.2 Nm). Overreaming to 52 mm had no further advantage in terms of primary stability or overhang. The geometric measurements showed significant differences as well. The previously clinically observed difficulties in inserting the cup were confirmed by this study. By overreaming to 51 mm, the drill-in behaviour, the primary stability and the measured overhang were comparable to the reference cup. The obtained results suggest that the extension of the acetabulum cavity to 51 mm while using the implantcast EcoFit size 50 should be implemented in clinical applications.


Sign in / Sign up

Export Citation Format

Share Document