Human serum albumin templated MnO2 nanosheets as an efficient biomimetic oxidase for biomolecule sensing

2020 ◽  
Vol 8 (48) ◽  
pp. 11090-11095
Author(s):  
Jia Ge ◽  
Jian-Hua Yu ◽  
Hongfen Yang ◽  
Dan Yang ◽  
Ren Cai

A colorimetric method for facile sensing of acid phosphatase activity based on HSA templated MnO2 nanosheets as an efficient biomimetic oxidase.

1966 ◽  
Vol 12 (4) ◽  
pp. 226-233 ◽  
Author(s):  
Bernard Klein ◽  
Morris Oklander ◽  
Stanley Morgenstern

Abstract A procedure is presented for the automated determination of acid phosphatase activity in biological materials using the Robot Chemist. Although either phenylphosphate and α-naphthylphosphate may be used as substrate in this analysis, the procedure is described in detail for serum acid phosphatase using α-naphthylphosphate in 0.1 M citrate, pH 5.2, since this substrate is more selective for prostatic acid phosphatase in human serum. Enzymically generated aα- naphthol is determined by the Emerson reaction (alkaline aminoantipyrine and ferricyanide), modified for use with this automated system. Correlations are presented between the results obtained on the Robot Chemist and the identical procedure developed for the AutoAnalyzer.


2020 ◽  
Vol 67 (3) ◽  
pp. 257-262
Author(s):  
Sonoko Yoshihiro ◽  
Takuya Ishigaki ◽  
Hayato Ookurano ◽  
Fumi Yoshitomi ◽  
Taeko Hotta ◽  
...  

1989 ◽  
Vol 35 (6) ◽  
pp. 939-945 ◽  
Author(s):  
A A Valcour ◽  
G N Bowers ◽  
R B McComb

Abstract The purity, spectral characteristics, and rate of nonenzymatic hydrolysis of 2,6-dichloro-4-nitrophenyl phosphate (DCNPP) were determined. Rates of DCNPP hydrolysis by prostatic acid phosphatase (PAP) and erythrocytic acid phosphatase (EAP) (both EC 3.1.3.2) were measured in the absence and in the presence of various alcohols. 1.5-Pentanediol was the most effective transphosphorylation agent for specifically enhancing the activity of PAP. 1,4-Butanediol also enhanced PAP activity but markedly inhibited EAP activity. Bovine and human serum albumin preparations also accelerated the hydrolysis of DCNPP. DCNPP can be used for the continuous or multipoint-rate assay of PAP.


Author(s):  
O. T. Minick ◽  
E. Orfei ◽  
F. Volini ◽  
G. Kent

Hemolytic anemias were produced in rats by administering phenylhydrazine or anti-erythrocytic (rooster) serum, the latter having agglutinin and hemolysin titers exceeding 1:1000.Following administration of phenylhydrazine, the erythrocytes undergo oxidative damage and are removed from the circulation by the cells of the reticulo-endothelial system, predominantly by the spleen. With increasing dosage or if animals are splenectomized, the Kupffer cells become an important site of sequestration and are greatly hypertrophied. Whole red cells are the most common type engulfed; they are broken down in digestive vacuoles, as shown by the presence of acid phosphatase activity (Fig. 1). Heinz body material and membranes persist longer than native hemoglobin. With larger doses of phenylhydrazine, erythrocytes undergo intravascular fragmentation, and the particles phagocytized are now mainly red cell fragments of varying sizes (Fig. 2).


1969 ◽  
Vol 08 (01) ◽  
pp. 15-21 ◽  
Author(s):  
K. E. Scheer ◽  
J. Heep ◽  
W. Maier-Borst ◽  
W. J. Lorenz ◽  
H. Sinn ◽  
...  

ZusammenfassungNach tierexperimentellen Voruntersuchungen wurde die Placentographie mit trägerfreiem 113Inm -HSA als klinische Methode eingeführt. Vor Amniocentesen und bei Verdacht auf Placenta praevia werden Placentographien geschrieben. Den Schwangeren wird eine Aktivität von 500 μCi in die Cubitalvene injiziert. Die der Aktivität entsprechende Indiummenge ist kleiner als 0,1 ng. Die fetale Strahlenbelastung liegt unter lOmrad. Bei Anwendung von 113Inm-HSA entfällt eine Blockade der mütterlichen und fetalen Schilddrüsen. Die genaue Abgrenzung einer Placenta praevia wird nicht durch eine Blasenaktivität beeinträchtigt.Es wurden bisher 19 Placentalokalisationen durchgeführt. In allen Fällen konnte der Placentasitz eindeutig festgestellt werden. Bedingt durch die lange Liegezeit beim Aufnehmen eines Szintigramms kam es in zwei Fällen zu einem Vena-Cava-Kompressions-Syndrom. Zur Verhinderung dieser klinischen Zwischenfälle werden inzwischen Placentographien mit der Anger-Kamera aufgenommen. Mit Hilfe des divergierenden Kollimators konnte der gesamte Abdominalbereich erfaßt werden. Die Aufnahmezeit konnte auf 7 — 10 Minuten verkürzt werden. Die intravenöse injizierte Aktivität betrug bei dieser Methode ebenfalls 500 μCi. Der diagnostische Aussagewert der Kamerabilder ist szintigraphischen Aufnahmen gleichwertig.


Sign in / Sign up

Export Citation Format

Share Document