A new [Co21(H2O)4(OH)12]30+ unit-incorporating polyoxotungstate for sensitive detection of dichlorvos

2020 ◽  
Vol 44 (26) ◽  
pp. 11336-11341 ◽  
Author(s):  
Dongying Shi ◽  
Chao-Jie Cui ◽  
Chun-Xiao Sun ◽  
Jun-Ping Du ◽  
Chun-Sen Liu

A new [Co21(H2O)4(OH)12]30+ unit-incorporating polyoxotungstate (denoted as Co25Si6W60) has been hydrothermally synthesized and fully characterized. The unique Co25Si6W60-based biosensing system offers an environmentally-friendly route for detecting dichlorvos.

RSC Advances ◽  
2016 ◽  
Vol 6 (59) ◽  
pp. 54518-54524 ◽  
Author(s):  
Krishnamoorthy Shanmugaraj ◽  
Malaichamy Ilanchelian

In this contribution, we have developed a simple, environmentally friendly fluorescent turn-off sensor for the detection of copper (Cu2+) ions in aqueous solution by using lysozyme stabilized gold nanoclusters (Lys-AuNCs) as a fluorescent probe.


Biosensors ◽  
2021 ◽  
Vol 11 (12) ◽  
pp. 523
Author(s):  
Chu-Tung Yeh ◽  
Devesh Barshilia ◽  
Chia-Jui Hsieh ◽  
Hsun-Yuan Li ◽  
Wen-Hsin Hsieh ◽  
...  

The rapid and sensitive detection of human C-reactive protein (CRP) in a point-of-care (POC) may be conducive to the early diagnosis of various diseases. Biosensors have emerged as a new technology for rapid and accurate detection of CRP for POC applications. Here, we propose a rapid and highly stable guided-mode resonance (GMR) optofluidic biosensing system based on intensity detection with self-compensation, which substantially reduces the instability caused by environmental factors for a long detection time. In addition, a low-cost LED serving as the light source and a photodetector are used for intensity detection and real-time biosensing, and the system compactness facilitates POC applications. Self-compensation relies on a polarizing beam splitter to separate the transverse-magnetic-polarized light and transverse-electric-polarized light from the light source. The transverse-electric-polarized light is used as a background signal for compensating noise, while the transverse-magnetic-polarized light is used as the light source for the GMR biosensor. After compensation, noise is drastically reduced, and both the stability and performance of the system are enhanced over a long period. Refractive index experiments revealed a resolution improvement by 181% when using the proposed system with compensation. In addition, the system was successfully applied to CRP detection, and an outstanding limit of detection of 1.95 × 10−8 g/mL was achieved, validating the proposed measurement system for biochemical reaction detection. The proposed GMR biosensing sensing system can provide a low-cost, compact, rapid, sensitive, and highly stable solution for a variety of point-of-care applications.


2021 ◽  
pp. 126123
Author(s):  
Le Thi Bao Ngoc ◽  
Duong Nhat Linh ◽  
Nguyen Van Minh ◽  
Nguyen Phuc Hoang Duy ◽  
Pham Thi Thuy Phuong

2014 ◽  
Vol 226 (03) ◽  
Author(s):  
T Vu-Han ◽  
MC Frühwald ◽  
M Hasselblatt ◽  
F Oyen ◽  
T Obser ◽  
...  

WRPMD'99 ◽  
1999 ◽  
Author(s):  
Larry A. Roesner ◽  
Robert W. Brashear

INEOS OPEN ◽  
2020 ◽  
Author(s):  
N. A. Samoilova ◽  

The enzyme-containing magnetic composites are presented. The magnetic matrix for enzyme immobilization is obtained by sequential application of an amine-containing polysaccharide—chitosan and a synthetic polymer—poly(ethylene-alt-maleic acid) to the magnetite microparticles to form the interpolyelectrolyte complex shell. Then, the enzyme (trypsin) is immobilized by covalent or noncovalent binding. Thus, the suggested composites can be readily obtained in the environmentally friendly manner. The enzyme capacity of the resulting composites reaches 28.0–32.6 mg/g. The maximum hydrolysis rates of the H-Val-Leu-Lys-pNA substrate provided by these composites range within 0.60·10–7–0.77·10–7 M/min.


2020 ◽  
pp. 9-12
Author(s):  
Viktor E. Lyubimov ◽  

Health of dairy cows ensures human health, so it is important that dairy products do not contain antibiotics that are used to treat any inflammation, including mastitis. In Russia at present, the problem of mastitis in cows exists with both attached and loose housing of cows. Mastitis of dairy cows are the great problem in milking husbandry. Losses from mastitis in milk yield can reach 15-20%. The main reasons for the occurrence of nonspecific mastitis of cows are the shortcomings of the working components of the milking machine: the degree of deterioration of the nipple rubber and the violation of machine milking technology (the reduction in pre-milking time and vacuum fluctuations account for 70% of all causes). Treatment of mastitis with antibiotics is effective, but not environmentally friendly and unacceptable. For the treatment of inflammation of the udder, it is necessary to use more environmentally friendly methods of treatment, one of which is the exposure to ultra-high frequency electromagnetic field tested by medicine. Use of three types of medical-mobile milking machines with the same method of exposure to ultrahigh-frequency electromagnetic fields on cow's nipples through electrodes in milking cups: LPDA-1-UHF, LPDA-2-UHF and LPDA-UHF-30 M, is described in the article. Author proved that cows with subclinical forms of mastitis recovered faster during milking with exposure to the ultrahigh frequency than when treated by antibiotics, and milking with the ultrahigh frequency device helps to recover 82% of the affected quarters with clinical forms and 100% of cows with subclinical forms of mastitis or with udder irritation. The high efficiency of the method of exposure to electromagnetic fields of the ultrahigh frequency during machine milking by means of medical-mobile milking machines LPDA-UHF for the prevention and treatment of mastitis of cows was shown.


Sign in / Sign up

Export Citation Format

Share Document