An improved spectrophotometric method tests the Einstein–Smoluchowski equation: a revisit and update

2020 ◽  
Vol 22 (38) ◽  
pp. 21784-21792
Author(s):  
Jiangbo (Tim) Zhao ◽  
Cong Qi ◽  
Guangrui Li ◽  
Markus A. Schmidt

We develop a highly accessible and accurate spectrophotometric method, and identify shortcomings of the Einstein–Smoluchowski equations in solvent scattering predictions.

Soft Matter ◽  
2020 ◽  
Vol 16 (32) ◽  
pp. 7513-7523
Author(s):  
J. M. Tavares ◽  
G. C. Antunes ◽  
C. S. Dias ◽  
M. M. Telo da Gama ◽  
N. A. M. Araújo

An analytical solution of a generalized Smoluchowski equation for linker-mediated aggregation, validated by computer simulations, describes experimental results for the time evolution of clustering.


1949 ◽  
Vol 21 (2) ◽  
pp. 315-315 ◽  
Author(s):  
N McDonald ◽  
Jacqueline Thompsett ◽  
J Mead

2004 ◽  
Vol 9 (4) ◽  
pp. 363-372 ◽  
Author(s):  
T. Lukaszewicz ◽  
A. Ravinski ◽  
I. Makoed

A new multilayer electrochromic device has been constructed according to the following pattern: glass1/ITO/WO3/gel electrolyte/BP/ITO/glass2, where ITO is a transparent conducting film made of indium and tin oxide and with the surface resistance equal 8–10 Ω/cm2 . The electrochromic devices obtained in the research are characterized by great (considerable) transmittance variation between coloration and bleaching state (25–40% at applied voltage of 1.5 to 3 V), and also high coloration efficiency (above 100 cm2 /C). Selfconsistent energy bands, dielectric permittivity and optical parameters are calculated using a full-potential linear muffin-tin orbital method. The numerical solution of the Debye-Smoluchowski equations is developed for simulating recombination probability of Li+ ions in amorphous electrolyte.


Author(s):  
Potdar S. S. ◽  
Karajgi S. R. ◽  
Simpi C. C. ◽  
Kalyane N. V.

The spectrophotometric method for estimation of CefpodoximeProxetil employed first derivative amplitude UV spectrophotometric method for analysis using methanol as solvent for the drug. CefpodoximeProxetil has absorbance maxima at 235nm and obeys Beer’s law in concentration range 10-50µg/ml with good linearity i.e. r2 about 0.999. The recovery studies established accuracy of the proposed method; result validated according to ICH guideline. Results were found satisfactory and reproducible. The method was successfully for evaluation of CefpodoximeProxetil in tablet dosage form without interference of common excipients.


Author(s):  
RUAA MUAYAD MAHMOOD ◽  
HAMSA MUNAM YASSEN ◽  
SAMAR , NAJWA ISSAC ABDULLA AHMED DARWEESH ◽  
NAJWA ISSAC ABDULLA

Simple, rapid and sensitive extractive spectrophotometric method is presented for the determination of glibenclamide (Glb) based on the formation of ion-pair complex between the Glb and anionic dye, methyl orange (MO) at pH 4. The yellow colored complex formed was quantitatively extracted into dichloromethane and measured at 426 nm. The colored product obeyed Beer’s law in the concentration range of (0.5-40) μg.ml-1. The value of molar absorptivity obtained from Beer’s data was found to be 31122 L.mol-1.cm-1, Sandell’s sensitivity value was calculated to be 0.0159 μg.cm-2, while the limits of detection (LOD) and quantification (LOQ) were found to be 0.1086 and 0.3292 μg.ml-1, respectively. The stoichiometry of the complex created between the Glb and MO was 1:1 as determined via Job’s method of continuous variation and mole ratio method. The method was successfully applied for the analysis of pharmaceutical formulation.


2019 ◽  
Author(s):  
Chem Int

Recent study was conducted to develop a simple UV spectrophotometric method to determine Phenytoin in bulk and injection form according to official requirement and validate as per ICH guidelines. λmax of Phenytoin was found 202 nm. Linearity existed perceived in the concentration assortment 2-8 μg/ml (r2 = 0.999) for the method. The method was validated pertaining to linearity, precision and accuracy studies, LOD and LOQ consistent with ICH guidelines. The existent method was establish to be simple, linear, precise, accurate as well as sensitive and can be applied for routine quality control enquiry for the analysis of Phenytoin in bulk and injection form.


Sign in / Sign up

Export Citation Format

Share Document